Investigating the Feasibility of Using DenseNet to Improve Coronary Calcification Detection in CT

被引:1
|
作者
Hou, Kuei-Yuan [1 ]
Yang, Ching-Ching [2 ,3 ,4 ]
机构
[1] Cathay Gen Hosp, Dept Radiol, Taipei, Taiwan
[2] Kaohsiung Med Univ, Dept Med Imaging & Radiol Sci, 100 Shin Chuan 1st Rd, Kaohsiung 80708, Taiwan
[3] Kaohsiung Med Univ Chung, Ho Mem Hosp, Dept Med Res, Kaohsiung, Taiwan
[4] Natl Yang Ming Chiao Tung Univ, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
关键词
coronary artery calcium scan; Agatston score; low dose; CT denoising; DenseNet; COMPUTED-TOMOGRAPHY; ITERATIVE RECONSTRUCTION; ARTERY-DISEASE; SCORE;
D O I
10.1016/j.acra.2022.10.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Interscan reproducibility of coronary artery calcium (CAC) scoring can be improved by using a smaller slice thickness but at the cost of higher image noise. This study aimed to investigate the feasibility of using densely connected convolutional network (DenseNet) to reduce the image noise in CAC scans reconstructed with slice thickness < 3 mm for improving coronary calcification detection in CT. Methods: Phantom data acquired with QRM and CIRS phantoms were used for model training and testing, where the DenseNet model adopted in this work was a convolutional neural network (CNN) designed for super resolution recovery. After phantom study, the proposed method was evaluated in terms of its ability to improve calcification detection using patient data. The CNN input images (IMGinput) were CAC scans reconstructed with 0.5-, 1.0- and 1.5-mm slice thickness, while CNN label images were CAC scans reconstructed with 3-mm slice thickness (IMG3mm).Region of interest (ROI) analysis was carried out on IMG3mm, IMGinput and CNN output images (IMGoutput). Twosample t test was used to compare the difference in Hounsfield Unit (HU) values within ROI between IMG3mm and IMGoutput. Results: For the calcifications in QRM phantoms, no statistically significant difference was found when comparing the HU values of 400and 800-HA calcifications identified on IMG3mm to those on IMGoutput with slice thickness of 0.5, 1.0 or 1.5 mm. On the other hand, statistically significant difference was found when comparing the HU values of 200-HA calcifications identified on IMG3mm to those on IMGoutput with a slice thickness of 0.5 and 1.0 mm. Meanwhile, no statistically significant difference was found when comparing the HU values of 200-HA calcifications identified on IMG3mm to those on IMGoutput with a slice thickness of 1.5 mm. As for the rod inserts in CIRS phantoms simulating 9 different tissue types in human body, there was no statistically significant difference between IMG3mm and IMGoutput with slice thickness of 1.5 mm, and all the p values were larger than 0.10. With regards to patient study, more calcification pixels were detected on IMGoutput with a slice thickness of 1.5 mm than on IMG3mm, so calcifications were more clear on the denoised images. Conclusion: According to our results, the CNN-based denoising method could reduce statistical noise in IMGinput with a slice thickness of 1.5 mm without causing significant texture change or variation in HU values. The proposed method could improve cardiovascular risk prediction by detecting small and soft calcifications that are barely identified on 3-mm slice images used in conventional CAC scans.
引用
收藏
页码:1600 / 1613
页数:14
相关论文
共 50 条
  • [1] A coronary calcification detection scheme using contrast enhanced CT dataset
    Li, Zhenwei
    Yang, Xiaoli
    Zhang, Jianguo
    [J]. Journal of Information and Computational Science, 2013, 10 (15): : 4835 - 4847
  • [2] DETECTION OF CORONARY CALCIFICATION IN ULTRAFAST CT COMPARED TO CORONARY ANGIOGRAPHY
    KOSLING, S
    HOFFMANN, U
    ROTHER, T
    LIEBERENZ, S
    HEYWANGKOBRUNNER, SH
    SCHULZ, HG
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (06): : 501 - 504
  • [3] 126 Comparison of coronary MR and CT angiography in detection of coronary stenosis with coronary calcification
    Xin Liu
    Christopher Francois
    David Tuite
    Debiao Li
    James Carr
    [J]. Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [4] Feasibility of CT Angiography-derived Kinetic Energy of Coronary Flow to Improve the Detection of Hemodynamically Significant Coronary Stenosis
    Tomizawa, Nobuo
    Nozaki, Yui
    Fujimoto, Shinichiro
    Fan, Ruiheng
    Takahashi, Daigo
    Kudo, Ayako
    Kamo, Yuki
    Aoshima, Chihiro
    Kawaguchi, Yuko
    Takamura, Kazuhisa
    Hiki, Makoto
    Dohi, Tomotaka
    Okazaki, Shinya
    Kumamaru, Kanako K.
    Minamino, Tohru
    Aoki, Shigeki
    [J]. RADIOLOGY-CARDIOTHORACIC IMAGING, 2022, 4 (06):
  • [5] ULTRAFAST CT FOR CORONARY CALCIFICATION
    不详
    [J]. LANCET, 1991, 337 (8755): : 1449 - 1450
  • [6] Effect of CT digital image compression on detection of coronary artery calcification
    Zheng, LM
    Sone, S
    Itani, Y
    Wang, Q
    Hanamura, K
    Asakura, K
    Li, F
    Yang, ZG
    Wang, JC
    Funasaka, T
    [J]. ACTA RADIOLOGICA, 2000, 41 (02) : 116 - 121
  • [7] INCIDENTAL CORONARY ARTERY CALCIFICATION DETECTION ON NON-CARDIAC CT
    Giblin, G.
    Sharma, N.
    McClelland, S.
    Hennessy, B.
    Collison, D.
    Fitzpatrick, N.
    Salim, T.
    Hussein, H.
    McAdam, B. F.
    [J]. HEART, 2015, 101 : A1 - A1
  • [8] VALUE OF USING CT TO DETECT CORONARY CALCIFICATION ON DIAGNOSIS OF CORONARY ARTERY DISEASE
    Ling, Sun
    Ling, Sun
    [J]. HEART, 2012, 98 : E166 - E166
  • [9] Electron-beam CT scanning for detection of coronary calcification and prediction of coronary heart disease
    Thompson, GR
    Forbat, S
    Underwood, R
    [J]. QJM-AN INTERNATIONAL JOURNAL OF MEDICINE, 1996, 89 (08) : 565 - 570
  • [10] Impact of obesity on aortic root calcification and coronary calcification using multi-detector CT
    Nafakhi, Hussein
    Al-Nafakh, Hasan A.
    Al-Mosawi, Abdulameer A.
    [J]. ARTERY RESEARCH, 2015, 9 : 27 - 32