Clinical performance comparison between lithium disilicate and hybrid resin nano-ceramic CAD/CAM onlay restorations: a two-year randomized clinical split-mouth study

被引:4
|
作者
Hassan, Amr [1 ]
Hamdi, Kareem [2 ,4 ]
Ali, Ashraf I. [1 ]
Al-Zordk, Walid [3 ]
Mahmoud, Salah Hasab [1 ,5 ]
机构
[1] Mansoura Univ, Fac Dent, Operat Dent Dept, Mansoura, Egypt
[2] Zagazig Univ, Fac Dent, Operat Dent Dept, Zagazig, Egypt
[3] Mansoura Univ, Fac Dent, Fixed Prosthodont Dept, Mansoura, Egypt
[4] Kareem Dent Clin, El Guesh St, Mansoura 35516, Egypt
[5] Horus Univ, Fac Dent, Operat Dept, New Damietta, Egypt
关键词
IPS e; max; Lithium disilicate; Hybrid ceramic; Resin nano-ceramic; Onlays; Indirect ceramic restorations; Partial coverage; INLAYS; SURVIVAL; WEAR; ADAPTATION; RESISTANCE; LONGEVITY; CEMENTS; SYSTEMS; SURFACE; TEETH;
D O I
10.1007/s10266-023-00841-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A total of 20 lithium disilicate glass-ceramics (IPS e.max CAD, Ivoclar Vivadent) and 20 resin nano-ceramic (Voco Grandio Blocks) onlay restorations were performed in 20 patients using a split-mouth design to compare the two-year clinical performance of lithium disilicate and resin nano-ceramic onlay restorations. Both restorations were evaluated at baseline, one-year, and two-year clinical follow-ups based on the modified United States Public Health Service (USPHS) criteria. Chi-square and Fisher's exact tests showed no statistically significant difference between Voco Grandio and IPS e.max ceramic restorations for all evaluated parameters during the different follow-up periods (p > 0.05). Cochrane's and MC-Nemar's tests indicated statistically significant differences regarding color match within the Voco Grandio group. They also indicated statistically significant differences in marginal discoloration, marginal adaptation, surface texture, and postoperative hypersensitivity within both ceramic material groups (p < 0.05). Kaplan-Meier curve indicated that the survival rate of both ceramic materials was 90%. After two years of clinical service, IPS e.max CAD and Voco Grandio onlay restorations exhibited similar clinical performance.
引用
收藏
页码:601 / 615
页数:15
相关论文
共 39 条
  • [1] Clinical performance comparison between lithium disilicate and hybrid resin nano-ceramic CAD/CAM onlay restorations: a two-year randomized clinical split-mouth study
    Amr Hassan
    Kareem Hamdi
    Ashraf I. Ali
    Walid Al-Zordk
    Salah Hasab Mahmoud
    [J]. Odontology, 2024, 112 : 601 - 615
  • [2] Two-year clinical performance of indirect restorations fabricated from CAD/CAM nano hybrid composite versus lithium disilicate in mutilated vital teeth. A randomized controlled trial
    Elmoselhy, Haneen Ahmad Shafik
    Hassanien, Olfat E. L. Sayed
    Haridy, Mohamed Fouad
    El Baz, Maha Abd El Salam
    Saber, Shehabeldin
    [J]. BMC ORAL HEALTH, 2024, 24 (01)
  • [3] Two-year performance of CAD/CAM fabricated resin composite inlay restorations: A randomized controlled clinical trial
    Tunac, Ayse T.
    Celik, Esra U.
    Yasa, Bilal
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (06) : 627 - 638
  • [4] Two-year evaluation of a nano-hybrid and a bulk-fill resin composite: a randomized, double-blind split-mouth clinical study
    Funda Çağırır Dindaroğlu
    Ece Yılmaz
    [J]. Clinical Oral Investigations, 28
  • [5] Two-year evaluation of a nano-hybrid and a bulk-fill resin composite: a randomized, double-blind split-mouth clinical study
    Dindaroglu, Funda Cagirir
    Yilmaz, Ece
    [J]. CLINICAL ORAL INVESTIGATIONS, 2024, 28 (04)
  • [6] Comparison of clinical efficacy of CAD CAM Endocrowns made of feldspathic ceramic, zirconia lithium silicate, and lithium disilicate: A two-year mixed cohort study
    Jalali, Samar
    Asgari, Nafiseh
    Pirooz, Parsa
    Younespour, Shima
    Atri, Faezeh
    [J]. JOURNAL OF DENTISTRY, 2024, 149
  • [7] A clinical evaluation of chairside lithium disilicate CAD/CAM crowns A two-year report
    Fasbinder, Dennis J.
    Dennison, Joseph B.
    Heys, Donald
    Neiva, Gisele
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 : 10S - 14S
  • [8] Two‑year clinical performance of indirect restorations fabricated from CAD/CAM nano hybrid composite versus lithium disilicate in mutilated vital teeth. A randomized controlled trial
    Haneen Ahmad Shafik Elmoselhy
    Olfat EL Sayed Hassanien
    Mohamed Fouad Haridy
    Maha Abd El Salam El Baz
    Shehabeldin Saber
    [J]. BMC Oral Health, 24
  • [9] Prospective Clinical Split-Mouth Study of Pressed and CAD/CAM All-Ceramic Partial-Coverage Restorations: 7-Year Results
    Guess, Petra C.
    Selz, Christian F.
    Steinhart, Yann-Niclas
    Stampf, Susanne
    Strub, Joerg R.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (01) : 21 - 25
  • [10] One-year clinical performance of lithium disilicate versus resin composite CAD/CAM onlays
    Joana Souza
    Mª Victoria Fuentes
    Eugenia Baena
    Laura Ceballos
    [J]. Odontology, 2021, 109 : 259 - 270