Corrosion under insulation mitigation by passive multivariate thermography

被引:1
|
作者
de Souza, Marcos Paulo Vieira [1 ]
Lopez, Fernando [2 ]
Maldague, Xavier [1 ]
机构
[1] Univ Laval, Elect & Comp Engn Dept, 1065 Ave Med, Quebec City, PQ G1V 0A6, Canada
[2] Torngats Inc, R&D Div, Quebec City, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1080/17686733.2024.2305917
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Corrosion under insulation (CUI) is one of the major concerns of oil and petrochemical installations as damage evolves invisibly under insulation layers and usually revealed on the occurrence of leaking or more catastrophic failure. Methods to early detect CUI and its causes is an urgent necessity to assure safety and performance of insulated process piping. Oil and petrochemical plants are often considered explosive environments in which thermal excitation devices are forbidden. The present work aims then on the consolidation of a passive thermographic methodology to reliably detect moisture trapped under insulation layers that will cause corrosion. The proposed methodology focuses on the thermal behaviour of the piping structure during process variations and interactions with the external ambient. The partial least-squares analysis showed promising performance on separating different physical phenomena, creating cleaner images for defect detection and extending the applicability of infrared thermography to the lower levels of surface emissivity that characterises clad insulation.