Comparison of pulmonary vein isolation using cryoballoon, high-power short-duration, and conventional radiofrequency ablation for atrial fibrillation: a propensity score-weighted study

被引:1
|
作者
Park, Hanjin [1 ]
Park, Je-Wook [1 ]
Kim, Daehoon [1 ]
Yu, Hee Tae [1 ]
Kim, Tae-Hoon [1 ]
Uhm, Jae-Sun [1 ]
Joung, Boyoung [1 ]
Lee, Moon-Hyoung [1 ]
Hwang, Chun [1 ]
Pak, Hui-Nam [1 ]
机构
[1] Yonsei Univ, Yonsei Univ Hlth Syst, Coll Med, Seoul, South Korea
来源
关键词
atrial fibrillation; catheter ablation; cryoballoon ablation; high-power short-duration ablation; heart rate variability; HEART-RATE-VARIABILITY; CATHETER ABLATION; MULTICENTER; CRYOABLATION; PERSISTENT; MECHANISMS;
D O I
10.3389/fcvm.2023.1238363
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The comparative efficacy, saftey, and heart rate variability (HRV) parameters after pulmonary vein isolation using cryoballoon (Cryo-PVI), high-power short-duration (HPSD-PVI), and conventional radiofrequency ablation (conventional-PVI) for atrial fibrillation (AF) is unclear.Materials and methods In this propensity score-weighted, retrospective analysis of a single-center cohort, we analyzed 3,395 patients (26.2% female, 74.5% paroxysmal AF) who underwent AF catheter ablation without an empirical left atrial ablation. Procedural factors, recurrence rates, complication rates, and the post-procedural HRV parameters were compared across the Cryo-PVI (n = 625), HPSD-PVI (n = 748), and conventional-PVI (n = 2,022) groups.Results Despite the shortest procedural time in the Cryo-PVI group (74 min for Cryo-PVI vs. 104 min for HPSD-PVI vs. 153 min for conventional-PVI, p < 0.001), the major complication (p = 0.906) and clinical recurrence rates were similar across the three ablation groups (weighted log-rank, p = 0.824). However, the Cryo-PVI group was associated with a significantly lower risk of recurrent AF in patients with paroxysmal AF [weighted hazard ratio (WHR) 0.57, 95% confidence interval (CI) 0.37-0.86], whereas it was associated with a higher risk of recurrent AF in patients with persistent AF (WHR 1.41, 95% CI 1.06-1.89, p for interaction of <0.001) compared with the conventional-PVI group. In the subgroup analysis for the HRV, the Cryo-PVI group had the highest low-frequency-to-high-frequency ratio at 1-year post-procedure, whereas the HPSD-PVI group had the lowest low-frequency-to-high-frequency ratio at 1-year post-procedure (p < 0.001).Conclusions The Cryo-PVI group had better rhythm outcomes in patients with paroxysmal AF but worse rhythm outcomes in patients with persistent AF and a higher long-term post-procedural sympathetic nervous activity and sympatho-vagal balance compared with the conventional-PVI group.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Pulmonary vein isolation for atrial fibrillation using true high-power short-duration vs. cryoballoon ablation
    Jonas Wörmann
    Jakob Lüker
    Jan-Hendrik van den Bruck
    Karlo Filipovic
    Susanne Erlhöfer
    Cornelia Scheurlen
    Sebastian Dittrich
    Jan-Hendrik Schipper
    Daniel Steven
    Arian Sultan
    Clinical Research in Cardiology, 2023, 112 : 846 - 852
  • [2] Pulmonary vein isolation for atrial fibrillation using true high-power short-duration vs. cryoballoon ablation
    Woermann, Jonas
    Lueker, Jakob
    van den Bruck, Jan-Hendrik
    Filipovic, Karlo
    Erlhoefer, Susanne
    Scheurlen, Cornelia
    Dittrich, Sebastian
    Schipper, Jan-Hendrik
    Steven, Daniel
    Sultan, Arian
    CLINICAL RESEARCH IN CARDIOLOGY, 2023, 112 (06) : 846 - 852
  • [3] Cryoballoon Versus High-Power, Short-Duration Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Paroxysmal Atrial Fibrillation A Single-Center, Prospective, Randomized Study
    Pak, Hui-Nam
    Park, Je-Wook
    Yang, Song-Yi
    Kim, Tae-Hoon
    Uhm, Jae-Sun
    Joung, Boyoung
    Lee, Moon-Hyoung
    Yu, Hee Tae
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2021, 14 (09): : E010040
  • [4] Revisiting pulmonary vein stenosis after high-power short-duration radiofrequency ablation in patients with atrial fibrillation
    Kim, J.
    Kim, D.
    Park, J.
    Yu, H.
    Kim, T.
    Uhm, J.
    Joung, B.
    Lee, M.
    Park, H.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [5] Multicenter prospective comparison of conventional and high-power short duration radiofrequency application for pulmonary vein isolation: the high-power short-duration radiofrequency application for faster and safer pulmonary vein ablation (POWER FAST III) trial
    Sergio Castrejón-Castrejón
    Marcel Martínez Cossiani
    Miguel Jáuregui-Abularach
    Nuria Basterra Sola
    José Luis Ibáñez Criado
    Joaquín Osca Asensi
    Ivo Roca Luque
    Angel Moya Mitjans
    Aurelio Quesada Dorador
    Víctor Manuel Hidalgo Olivares
    Nicasio Pérez Castellano
    Juan Manuel Fernández Gómez
    María Rosa Macías-Ruiz
    Bruno Bochard Villanueva
    Nerea Gonzalo Bada
    Andrés Fernández Prieto
    Leonardo Elías Guido López
    María Eugenia Martínez Maldonado
    Daniel Merino
    Carlos Escobar Cervantes
    José Luis Merino
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1889 - 1899
  • [6] Multicenter prospective comparison of conventional and high-power short duration radiofrequency application for pulmonary vein isolation: the high-power short-duration radiofrequency application for faster and safer pulmonary vein ablation (POWER FAST III) trial
    Castrejon-Castrejon, Sergio
    Cossiani, Marcel Martinez
    Jauregui-Abularach, Miguel
    Sola, Nuria Basterra
    Criado, Jose Luis Ibanez
    Asensi, Joaquin Osca
    Luque, Ivo Roca
    Mitjans, Angel Moya
    Dorador, Aurelio Quesada
    Olivares, Victor Manuel Hidalgo
    Castellano, Nicasio Perez
    Gomez, Juan Manuel Fernandez
    Macias-Ruiz, Maria Rosa
    Villanueva, Bruno Bochard
    Bada, Nerea Gonzalo
    Prieto, Andres Fernandez
    Lopez, Leonardo Elias Guido
    Maldonado, Maria Eugenia Martinez
    Merino, Daniel
    Cervantes, Carlos Escobar
    Merino, Jose Luis
    OWER FAST III trial invest
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (08) : 1889 - 1899
  • [7] Update on high-power short-duration ablation for pulmonary vein isolation
    Qiu, Jie
    Wang, Yan
    Wang, Dao W.
    Hu, Mei
    Chen, Guangzhi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (09) : 2499 - 2508
  • [8] Revisiting symptomatic pulmonary vein stenosis after high-power short-duration radiofrequency ablation in patients with atrial fibrillation
    Kim, Joongmin
    Kim, Daehoon
    Yu, Hee Tae
    Kim, Tae-Hoon
    Joung, Boyoung
    Lee, Moon-Hyoung
    Pak, Hui-Nam
    EUROPACE, 2023, 25 (10):
  • [9] Biophysical parameters of pulmonary vein isolation with very high-power short-duration compared to conventional radiofrequency ablation guided by ablation index
    Duarte, F. Fabiana
    Silva-Teixeira, R.
    Almeida, J. Goncalves
    Fonseca, P.
    Oliveira, M.
    Goncalves, H.
    Primo, J.
    Fontes-Carvalho, R.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 6 - 6
  • [10] High-power, short-duration ablation during Box isolation for atrial fibrillation
    Kumagai, Koichiro
    Toyama, Hideko
    JOURNAL OF ARRHYTHMIA, 2020, 36 (05) : 899 - 904