DopUS-Net: Quality-Aware Robotic Ultrasound Imaging Based on Doppler Signal

被引:9
|
作者
Jiang, Zhongliang [1 ]
Duelmer, Felix [1 ]
Navab, Nassir [1 ]
机构
[1] Tech Univ Munich, Chair Comp Aided Med Procedures & Augmented Real, D-85748 Garching, Germany
关键词
Image segmentation; Doppler effect; Robots; Biomedical imaging; Arteries; Three-dimensional displays; Ultrasonic imaging; Robotic ultrasound; vessel segmentation; ultrasound segmentation; 3D visualization;
D O I
10.1109/TASE.2023.3277331
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Medical ultrasound (US) is widely used to evaluate and stage vascular diseases, in particular for the preliminary screening program, due to the advantage of being radiation-free. However, automatic segmentation of small tubular structures (e.g., the ulnar artery) from cross-sectional US images is still challenging. To address this challenge, this paper proposes the DopUS-Net and a vessel re-identification module that leverage the Doppler effect to enhance the final segmentation result. Firstly, the DopUS-Net combines the Doppler images with B-mode images to increase the segmentation accuracy and robustness of small blood vessels. It incorporates two encoders to exploit the maximum potential of the Doppler signal and recurrent neural network modules to preserve sequential information. Input to the first encoder is a two-channel duplex image representing the combination of the grey-scale Doppler and B-mode images to ensure anatomical spatial correctness. The second encoder operates on the pure Doppler images to provide a region proposal. Secondly, benefiting from the Doppler signal, this work first introduces an online artery re-identification module to qualitatively evaluate the real-time segmentation results and automatically optimize the probe pose for enhanced Doppler images. This quality-aware module enables the closed-loop control of robotic screening to further improve the confidence and robustness of image segmentation. The experimental results demonstrate that the proposed approach with the re-identification process can significantly improve the accuracy and robustness of the segmentation results (Dice score: from 0.54 to 0.86; intersection over union: from 0.47 to 0.78). Note to Practitioners-The Doppler signal is important for the diagnosis of vascular disease, e.g., peripheral arterial disease, in clinical practices, nevertheless it is not of similar significance for state-of-the-art robotic ultrasound (US) examination systems yet. This paper explores various neural network structures to effectively extract the blood vessels from US images by incorporating the Doppler signal into the segmentation process. The final DopUS structure with two encoders extracting differentiated information from two different inputs and fusing the latent feature representations in the bottleneck layer can also inspire other tasks like multi-senor fusion. In addition, this work developed a Doppler-based tracker to assess the quality of the segmentation results in real-time. The assessment is subsequently used for a quality-aware module that enables closed-loop control of the robotic screening. Preliminary physical experiments suggest that the quality-aware robotic screening system can improve the confidence and robustness of autonomous US examination results. In the future, the Doppler signal could also be used to support clinical diagnosis. We believe the proposed quality-aware autonomous screening system is important for the development of large-scale robotic US screening programs. It will not only benefit the examination of limb arteries but also other vascular structures, e.g., carotid or aorta.
引用
收藏
页码:3229 / 3242
页数:14
相关论文
共 50 条
  • [1] Energy and Quality-Aware Multimedia Signal Processing
    Emre, Yunus
    Chakrabarti, Chaitali
    IEEE TRANSACTIONS ON MULTIMEDIA, 2013, 15 (07) : 1579 - 1593
  • [2] Quality-Aware Query Based on Relative Source Quality
    Li, Mohan
    Sun, Yanbin
    Wang, Le
    Lu, Hui
    CLOUD COMPUTING AND SECURITY, PT II, 2018, 11064 : 3 - 8
  • [3] SIGNAL-PROCESSING IN ULTRASOUND IMAGING, DOPPLER AND DOPPLER IMAGING
    BURCKHARDT, CB
    ULTRASCHALL IN DER MEDIZIN, 1993, 14 (05): : 220 - 224
  • [4] Energy-efficient and quality-aware part placement in robotic additive manufacturing
    Ghungrad, Suyog
    Mohammed, Abdullah
    Haghighi, Azadeh
    JOURNAL OF MANUFACTURING SYSTEMS, 2023, 68 : 644 - 650
  • [5] Model based development of quality-aware software services
    de Miguel, Miguel A.
    Massonet, Philippe
    Silva, Juan P.
    Briones, Javier
    ISORC 2008: 11TH IEEE SYMPOSIUM ON OBJECT/COMPONENT/SERVICE-ORIENTED REAL-TIME DISTRIBUTED COMPUTING - PROCEEDINGS, 2008, : 563 - +
  • [6] A Knowledge-based approach for quality-aware ETL process
    Hamed, Imen
    Ghozzi, Faiza
    2015 6TH INTERNATIONAL CONFERENCE ON INFORMATION SYSTEMS AND ECONOMIC INTELLIGENCE (SIIE), 2015, : 104 - 112
  • [7] AspectIX: A quality-aware, object-based middleware architecture
    Hauck, FJ
    Becker, U
    Geier, M
    Meier, E
    Rastofer, U
    Steckermeier, M
    NEW DEVELOPMENTS IN DISTRIBUTED APPLICATIONS AND INTEROPERABLE SYSTEMS, 2001, 70 : 115 - 120
  • [8] Quality-Aware Review Selection Based on Product Feature Taxonomy
    Tian, Nan
    Xu, Yue
    Li, Yuefeng
    Pasi, Gabriella
    INFORMATION RETRIEVAL TECHNOLOGY, AIRS 2015, 2015, 9460 : 68 - 80
  • [9] Quality-Aware Signal Processing Mechanism of PPG Signal for Long-Term Heart Rate Monitoring
    Beh, Win-Ken
    Yang, Yu-Chia
    Wu, An-Yeu
    SENSORS, 2024, 24 (12)
  • [10] Blind image quality assessment based on aesthetic and statistical quality-aware features
    Jenadeleh, Mohsen
    Masaeli, Mohammad Masood
    Moghaddam, Mohsen Ebrahimi
    JOURNAL OF ELECTRONIC IMAGING, 2017, 26 (04)