How searching against multiple libraries can lead to biased results in GC/MS-based metabolomics

被引:3
|
作者
Samokhin, Andrey S. [1 ,3 ]
Matyushin, Dmitriy D. [2 ]
机构
[1] Lomonosov Moscow State Univ, Chem Dept, Moscow, Russia
[2] Russian Acad Sci, AN Frumkin Inst Phys Chem & Electrochem, Moscow, Russia
[3] Lomonosov Moscow State Univ, Chem Dept, Leninskie Gory 1 3, Moscow 119991, Russia
基金
俄罗斯科学基金会;
关键词
MASS-SPECTROMETRY; IDENTIFICATION; COMPOUND; ALGORITHMS;
D O I
10.1002/rcm.9437
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleDatabases of electron ionization mass spectra are often used in GC/MS-based untargeted metabolomics analysis. The results of the library search depend on several factors, such as the size and quality of the database, and the library search algorithm. We found out that the list of considered m/z values is another important parameter. Unfortunately, this information is not usually specified by software developers and it is hidden from the end user. MethodsWe created synthetic data sets and figured out how several popular software products (AMDIS, ChromaTOF, MS Search, and Xcalibur) select the list of m/z values for the library search. Moreover, we considered data sets of real mass spectra (presented in both the NIST and FiehnLib libraries) and compared the library search results obtained within different software products. All programs under consideration use the NIST MS Search binaries to perform the library search using the Identity algorithm. ResultsWe found that AMDIS and ChromaTOF can give biased library search results under particular conditions. In untargeted metabolomics, this can happen when NIST and FiehnLib libraries are used simultaneously, the scan range of the instrument is less than 85, and the correct answer is present only in the FiehnLib library. ConclusionsThe main reason for biased results is that the information about the scan range is not stored in the metadata of library records. As a result, in the case of AMDIS and ChromaTOF software, some unrecorded peaks are considered as missing during the library search, the respective compound is penalized, and the correct answer falls outside the top five or even top 10 hits. At the same time, the default algorithm for selecting the list of considered m/z values implemented in MS Search is free from such unexpected behavior.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Identification of antifungal quinolizidines using GC/MS-based metabolomics
    Cely-Veloza, W.
    Coy-Barrera, E.
    PLANTA MEDICA, 2019, 85 (18) : 1462 - 1462
  • [2] Guidelines and considerations for building multidimensional libraries for untargeted MS-based metabolomics
    da Silva, Katyeny Manuela
    van de Lavoir, Maria
    Robeyns, Rani
    Iturrospe, Elias
    Verheggen, Lisa
    Covaci, Adrian
    van Nuijs, Alexander L. N.
    METABOLOMICS, 2022, 19 (01)
  • [3] Guidelines and considerations for building multidimensional libraries for untargeted MS-based metabolomics
    Katyeny Manuela da Silva
    Maria van de Lavoir
    Rani Robeyns
    Elias Iturrospe
    Lisa Verheggen
    Adrian Covaci
    Alexander L. N. van Nuijs
    Metabolomics, 19
  • [4] Comparison of sequential derivatization with concurrent methods for GC/MS-based metabolomics
    Miyagawa, Hiromi
    Bamba, Takeshi
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2019, 127 (02) : 160 - 168
  • [5] Evaluation and optimization of sample pretreatment for GC/MS-based metabolomics in embryonic zebrafish
    Yan, Shi-Chao
    Chen, Zhi-Feng
    Zhang, Hui
    Chen, Yanyan
    Qi, Zenghua
    Liu, Guoguang
    Cai, Zongwei
    TALANTA, 2020, 207
  • [6] Identification of highly sensitive biomarkers that can aid the early detection of pancreatic cancer using GC/MS/MS-based targeted metabolomics
    Hirata, Yuichi
    Kobayashi, Takashi
    Nishiumi, Shin
    Yamanaka, Kodai
    Nakagawa, Takashi
    Fujigaki, Seiji
    Iemoto, Takao
    Kobayashi, Makoto
    Okusaka, Takuji
    Nakamori, Shoji
    Shimahara, Masashi
    Ueno, Takaaki
    Tsuchida, Akihiko
    Sata, Naohiro
    Ioka, Tatsuya
    Yasunami, Yohichi
    Kosuge, Tomoo
    Kaneda, Takashi
    Kato, Takao
    Yagihara, Kazuhiro
    Fujita, Shigeyuki
    Yamada, Tesshi
    Honda, Kazufumi
    Azuma, Takeshi
    Yoshida, Masaru
    CLINICA CHIMICA ACTA, 2017, 468 : 98 - 104
  • [7] Optimal Normalization Method for GC-MS/MS-Based Large-Scale Targeted Metabolomics
    Xue, Liming
    Xu, Jiale
    Feng, Chao
    Lu, Dasheng
    Zhou, Zhijun
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (03) : 361 - 368
  • [8] Optimal Normalization Method for GC-MS/MS-Based Large-Scale Targeted Metabolomics
    Liming Xue
    Jiale Xu
    Chao Feng
    Dasheng Lu
    Zhijun Zhou
    Journal of Analytical Chemistry, 2022, 77 : 361 - 368
  • [9] GC/MS-based urine metabolomics analysis of renal allograft recipients with acute rejection
    Long Zheng
    Jina Wang
    Wenjun Gao
    Chao Hu
    Shuo Wang
    Ruiming Rong
    Yinlong Guo
    Tongyu Zhu
    Dong Zhu
    Journal of Translational Medicine, 16
  • [10] GC/MS-based metabolomics detects metabolic alterations in serum from SLE patients
    Saegusa, J.
    Irino, Y.
    Yoshida, M.
    Tanaka, S.
    Kogata, Y.
    Kageyama, G.
    Tsuji, G.
    Takenawa, T.
    Kawano, S.
    Kumagai, S.
    Morinobu, A.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2014, 32 (01) : 148 - 148