Numerical investigation of impinging jet ventilation in ICUs: Is thermal stratification a problem?

被引:7
|
作者
Wang, Lei [1 ,2 ]
Wang, Zhiqiang [3 ]
Zhu, Sirui [3 ]
Zhu, Zhe [4 ]
Jin, Tao [1 ]
Wei, Jianjian [1 ,2 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Key Lab Refrigerat & Cryogen Technol Zhejiang Prov, Hangzhou, Peoples R China
[2] Zhejiang Univ, Ctr Balance Architecture, Hangzhou, Peoples R China
[3] Zhejiang Univ Co Ltd, Architectural Design & Res Inst, Hangzhou, Peoples R China
[4] Zhejiang Modern Architectural Design & Res Inst Co, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
impinging jet ventilation; heat sources; air change rates; respiratory particles; lock-up phenomenon; LOCK-UP PHENOMENON; EXHALED AIR; FLOW; PARTICLES; PERFORMANCE; DEPOSITION; TRANSPORT; DROPLETS; MOVEMENT; EXPOSURE;
D O I
10.1007/s12273-023-1023-3
中图分类号
O414.1 [热力学];
学科分类号
摘要
Intensive care units (ICUs) are the high incidence sites of hospital-acquired infections, where impinging jet ventilation (IJV) shows great potential. Thermal stratification of IJV and its effect on contaminants distribution were systematically investigated in this study. By changing the setting of heat source or the air change rates, the main driving force of supply airflow can be transformed between thermal buoyancy and inertial force, which can be quantitatively described by the dimensionless buoyant jet length scale ((l) over bar (m)). For the investigated air change rates, namely 2 ACH to 12 ACH, (l) over bar (m) varies between 0.20 and 2.80. The thermal buoyancy plays a dominant role in the movement of the horizontally exhaled airflow by the infector under low air change rate, where the temperature gradient is up to 2.45 degrees C/m. The flow center remains close to the breathing zone of the susceptible ahead, resulting into the highest exposure risk (6.6 parts per thousand for 10-mu m particles). With higher heat flux of four PC monitors (from 0 W to 125.85 W for each monitor), the temperature gradient in ICU rises from 0.22 degrees C/m to 1.02 degrees C/m; however, the average normalized concentration of gaseous contaminants in the occupied zone is reduced from 0.81 to 0.37, because their thermal plumes are also able to carry containments around them to the ceiling-level readily. As the air change rate was increased to 8 ACH ((l) over bar (m) = 1.56), high momentum weakened the thermal stratification by reducing the temperature gradient to 0.37 degrees C/m and exhaled flow readily rose above the breathing zone; the intake fraction of susceptible patient located in front of the infector for 10-mu m particles reduces to 0.8%. This study proved the potential application of IJV in ICUs and provides theoretical guidance for its appropriate design.
引用
收藏
页码:1173 / 1185
页数:13
相关论文
共 50 条
  • [1] Numerical investigation of impinging jet ventilation in ICUs: Is thermal stratification a problem?
    Lei Wang
    Zhiqiang Wang
    Sirui Zhu
    Zhe Zhu
    Tao Jin
    Jianjian Wei
    Building Simulation, 2023, 16 : 1173 - 1185
  • [2] Numerical study on thermal stratification for impinging jet ventilation system in office buildings
    Hu, Jun
    Kang, Yanming
    Yu, Jia
    Zhong, Ke
    Building and Environment, 2021, 196
  • [3] Numerical study on thermal stratification for impinging jet ventilation system in office buildings
    Hu, Jun
    Kang, Yanming
    Yu, Jia
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2021, 196
  • [4] Numerical investigation of the thermal and ventilation performance of a combined impinging jet ventilation and passive chilled beam system
    Hu, Jun
    Kang, Yanming
    Lu, Yihang
    Yu, Jia
    Li, He
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2022, 226
  • [5] Numerical investigation of the thermal and ventilation performance of a combined impinging jet ventilation and passive chilled beam system
    Hu, Jun
    Kang, Yanming
    Lu, Yihang
    Yu, Jia
    Li, He
    Zhong, Ke
    Building and Environment, 2022, 226
  • [6] Numerical investigation of indoor thermal comfort and air quality for an office equipped with corner impinging jet ventilation
    Ameen, Arman
    Cehlin, Mathias
    Karimipanah, Taghi
    ADVANCES IN BUILDING ENERGY RESEARCH, 2023, 17 (05) : 578 - 604
  • [7] Computational investigation on the factors influencing thermal comfort for impinging jet ventilation
    Chen, Huijuan
    Moshfegh, Bahram
    Cehlin, Mathias
    BUILDING AND ENVIRONMENT, 2013, 66 : 29 - 41
  • [8] Numerical investigation of the flow behavior of an isothermal corner impinging jet for building ventilation
    Ameen, Arman
    Cehlin, Mathias
    Larsson, Ulf
    Yamasawa, Haruna
    Kobayashi, Tomohiro
    BUILDING AND ENVIRONMENT, 2022, 223
  • [9] Numerical investigation and analysis of indoor air quality in a room based on impinging jet ventilation
    Koufi, Lounes
    Younsi, Zohir
    Cherif, Yassine
    Naji, Hassane
    MATERIALS & ENERGY I (2015) / MATERIALS & ENERGY II (2016), 2017, 139 : 710 - 717
  • [10] Simplified models for predicting thermal stratification in impinging jet ventilation rooms using multiple regression analysis
    Hu, Jun
    Kang, Yanming
    Lu, Yihang
    Yu, Jia
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2021, 206