Rapid Detection of Hepatitis A Virus in Foods Using a Bioluminescent Assay in Real-Time (BART) and Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Technology

被引:11
|
作者
Wu, Ruiqin [1 ,2 ]
Meng, Baozhong [3 ]
Corredig, Milena [1 ]
Griffiths, Mansel W. W. [1 ,2 ]
机构
[1] Univ Guelph, Dept Food Sci, 50 Stone Rd East, Guelph, ON N1G 2W1, Canada
[2] Canadian Res Inst Food Safety, 43 McGilvray St, Guelph, ON N1G 2W1, Canada
[3] Univ Guelph, Dept Mol & Cellular Biol, 50 Stone Rd East, Guelph, ON N1G 2W1, Canada
关键词
Hepatitis A virus; Detection; RT-LAMP-BART; Food; QUANTITATIVE DETECTION; COLORIMETRIC DETECTION; VISUAL DETECTION; ENTERIC VIRUSES; PCR; PATHOGENS; CHIP; GENE; DNA; IDENTIFICATION;
D O I
10.1007/s12560-022-09548-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Foodborne hepatitis A infections have been considered as a major threat for public health worldwide. Increased incidences of hepatitis A virus (HAV) infection has been associated with growing global trade of food products. Rapid and sensitive detection of HAV in foods is very essential for investigating the outbreaks. Real-time RT-PCR has been most widely used for the detection of HAV by far. However, the technology relies on fluorescence determination of the amplicon and requires sophisticated, high-cost instruments and trained personnel, limiting its use in low resource settings. In this study, a robust, affordable, and simple assay, reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay in combination with a bioluminescence-based determination of amplification in real-time (BART), was developed for the detection of HAV in different food matrices, including green onion, strawberry, mussel, and milk. The efficiencies of a one-step RT-LAMP-BART and a two-step RT-LAMP-BART were investigated for the detection of HAV in different food matrices and was compared with that of real-time RT-PCR. The sensitivity of the RT-LAMP-BART assay was significantly affected by Mg2+ concentration (P < 0.05), in addition to primer quality. The optimal Mg2+ concentration was 2 mM for one-step RT-LAMP-BART and 4 mM for two-step RT-LAMP-BART. Compared with cartridge-purified primers, HPLC-purified primers could greatly improve the sensitivity of the RT-LAMP-BART assay (P < 0.05). For detecting HAV in different food matrices, the performance of two-step RT-LAMP-BART was comparable with that of real-time RT-PCR and was better than that of one-step RT-LAMP-BART. The detection limit of the two-step RT-LAMP-BART for HAV in green onion, strawberry, mussel, and milk was 8.3 x 10(0) PFU/15 g, 8.3 x 10(1) PFU/50 g, 8.3 x 10(0) PFU/5 g, and 8.3 x 10(0) PFU/40 mL, respectively. The developed RT-LAMP-BART was an effective, simple, sensitive, and robust method for foodborne HAV detection.
引用
收藏
页码:144 / 157
页数:14
相关论文
共 50 条
  • [1] Rapid Detection of Hepatitis A Virus in Foods Using a Bioluminescent Assay in Real-Time (BART) and Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Technology
    Ruiqin Wu
    Baozhong Meng
    Milena Corredig
    Mansel W. Griffiths
    Food and Environmental Virology, 2023, 15 : 144 - 157
  • [2] Rapid detection of Akabane virus by a novel reverse transcription loop-mediated isothermal amplification assay (RT-LAMP)
    Qiao, Jun
    Wang, Junwei
    Meng, Qingling
    Wang, Guochao
    Liu, Yucheng
    He, Zhihao
    Yang, Haibo
    Zhang, Zaichao
    Cai, Xuepeng
    Chen, Chuangfu
    VIROLOGY JOURNAL, 2013, 10
  • [3] Rapid detection of Akabane virus by a novel reverse transcription loop-mediated isothermal amplification assay (RT-LAMP)
    Jun Qiao
    Junwei Wang
    Qingling Meng
    Guochao Wang
    Yucheng Liu
    Zhihao He
    Haibo Yang
    Zaichao Zhang
    Xuepeng Cai
    Chuangfu Chen
    Virology Journal, 10
  • [4] Rapid and real-time detection of hepatitis A virus by reverse transcription loop-mediated isothermal amplification assay
    Yoneyama, Tetsuo
    Kiyohara, Tomoko
    Shimasaki, Noriko
    Kobayashi, Gen
    Ota, Yoshinori
    Notomi, Tsugunori
    Totsuka, Atsuko
    Wakita, Takaji
    JOURNAL OF VIROLOGICAL METHODS, 2007, 145 (02) : 162 - 168
  • [5] Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for the Specific and Rapid Detection of Tilapia Lake Virus
    Phusantisampan, Theerawut
    Rawiwan, Pattarasuda
    Roy, Sri Rajiv Kumar
    Sriariyanun, Malinee
    Surachetpong, Win
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):
  • [6] Rapid Detection of Tembusu Virus by Reverse-Transcription, Loop-mediated Isothermal Amplification (RT-LAMP)
    Tang, Y.
    Diao, Y.
    Yu, C.
    Gao, X.
    Chen, L.
    Zhang, D.
    TRANSBOUNDARY AND EMERGING DISEASES, 2012, 59 (03) : 208 - 213
  • [7] Rapid and sensitive detection of porcine torovirus by a reverse transcription loop-mediated isothermal amplification assay (RT-LAMP)
    Liu, Xiaowan
    Zhou, Yuancheng
    Yang, Fan
    Liu, Pengjuan
    Cai, Yuhan
    Huang, Jianbo
    Zhu, Ling
    Xu, Zhiwen
    JOURNAL OF VIROLOGICAL METHODS, 2016, 228 : 103 - 107
  • [8] Reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for rapid diagnosis of chilli veinal mottle virus
    Banerjee, Amrita
    Roy, Somnath
    Sharma, Susheel Kumar
    Dutta, Sudip Kumar
    Chandra, Satish
    Ngachan, S. V.
    ARCHIVES OF VIROLOGY, 2016, 161 (07) : 1957 - 1961
  • [9] Reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for rapid diagnosis of chilli veinal mottle virus
    Amrita Banerjee
    Somnath Roy
    Susheel Kumar Sharma
    Sudip Kumar Dutta
    Satish Chandra
    SV Ngachan
    Archives of Virology, 2016, 161 : 1957 - 1961
  • [10] Detection of enterovirus 71 using reverse transcription loop-mediated isothermal amplification (RT-LAMP)
    Wang, Xiang
    Zhu, Jun-ping
    Zhang, Qian
    Xu, Zi-gang
    Zhang, Fang
    Zhao, Zhi-hui
    Zheng, Wen-zhi
    Zheng, Li-shu
    JOURNAL OF VIROLOGICAL METHODS, 2012, 179 (02) : 330 - 334