CO2 concentration as an indicator of indoor ventilation performance to control airborne transmission of SARS-CoV-2

被引:10
|
作者
Park, Sowoo [1 ]
Song, Doosam [2 ]
机构
[1] Sungkyunkwan Univ, Grad Sch, Suwon 16419, South Korea
[2] Sungkyunkwan Univ, Sch Civil Architectural Eng & Landscape Architect, Suwon 16419, South Korea
关键词
SARS-CoV-2; Airborne transmission; Probability of infection; Rebreathed fraction; CO; 2; concentration; RISK;
D O I
10.1016/j.jiph.2023.05.011
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The Wells-Riley equation has been extensively used to quantify the infection risk of airborne transmission indoors. This equation is difficult to apply to actual conditions because it requires measurement of the outdoor air supply rate, which vary with time and are difficult to quantify. The method of determining the fraction of inhaled air that has been exhaled previously by someone in a building using a CO2 concentration measurement can solve the limitations of the existing method. Using this method, the indoor CO2 concentration threshold can be determined to keep the risk of infection below certain conditions.Methods: Based on the calculation of the rebreathed fraction, an appropriate mean indoor CO2 concentration and required air exchange rate to control SARS-CoV-2 airborne transmission was calculated. The number of indoor occupants, ventilation rate, and the deposition and inactivation rates of the virus-laden aerosols were considered. The application of the proposed indoor CO2 concentration-based infection rate control was investigated through case studies in school classrooms and restaurants.Results: In a typical school classroom environment with 20-25 occupants and an exposure time of 6-8 h, the average indoor CO2 concentration should be kept below 700 ppm to control the risk of airborne infection indoors. The ASHRAE recommended ventilation rate is sufficient when wearing a mask in classrooms. For a typical restaurant with 50-100 occupants and an exposure time of 2-3 h, the average indoor CO2 concentration should be kept below about 900 ppm. Residence time in the restaurant had a significant effect on the acceptable CO2 concentration.Conclusion: Given the conditions of the occupancy environment, it is possible to determine an indoor CO2 concentration threshold, and keeping the CO2 concentration lower than a certain threshold could help reduce the risk of COVID-19 infection.(c) 2023 Published by Elsevier Ltd on behalf of King Saud Bin Abdulaziz University for Health Sciences. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1037 / 1044
页数:8
相关论文
共 50 条
  • [1] On airborne transmission and control of SARS-Cov-2
    Yao, Maosheng
    Zhang, Lu
    Ma, Jianxin
    Zhou, Lian
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 731
  • [2] Graphical-mathematical model to estimate CO2 concentration level as an indicator of SARS-CoV-2 transmission
    Razura-Carmona, F. F.
    Navidad-Murrieta, M. S.
    Barajas-Carrillo, V. W.
    Covantes- Rosales, C. E.
    Diaz-Resendiz, K. J. G.
    Toledo-Ibarra, G. A.
    Ventura-Ramon, G. H.
    Ojeda-Duran, A. J.
    Casas-Rodriguez, J. O.
    Giron-Perez, M. I.
    REVISTA BIO CIENCIAS, 2023, 10
  • [3] Airborne transmission of SARS-CoV-2
    Prather, Kimberly A.
    Marr, Linsey C.
    Schooley, Robert T.
    McDiarmid, Melissa A.
    Wilson, Mary E.
    Milton, Donald K.
    SCIENCE, 2020, 370 (6514) : 303 - 304
  • [4] Recognizing and controlling airborne transmission of SARS-CoV-2 in indoor environments
    Allen, Joseph G.
    Marr, Linsey C.
    INDOOR AIR, 2020, 30 (04) : 557 - 558
  • [5] Airborne transmission of SARS-CoV-2 in indoor environments: A comprehensive review
    Shen, Jialei
    Kong, Meng
    Dong, Bing
    Birnkrant, Michael J.
    Zhang, Jianshun
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2021, 27 (10) : 1331 - 1367
  • [6] On the airborne transmission of SARS-CoV-2 and relationship with indoor conditions at a hospital
    Baboli, Zeynab
    Neisi, Niloofar
    Babaei, Ali Akbar
    Ahmadi, Mehdi
    Sorooshian, Armin
    Birgani, Yaser Tahmasebi
    Goudarzi, Gholamreza
    ATMOSPHERIC ENVIRONMENT, 2021, 261
  • [7] Indoor transmission of SARS-CoV-2
    Qian, Hua
    Miao, Te
    Liu, Li
    Zheng, Xiaohong
    Luo, Danting
    Li, Yuguo
    INDOOR AIR, 2021, 31 (03) : 639 - 645
  • [8] CO2 concentration monitoring inside educational buildings as a strategic tool to reduce the risk of Sars-CoV-2 airborne transmission
    Di Gilio, Alessia
    Palmisani, Jolanda
    Pulimeno, Manuela
    Cerino, Fabio
    Cacace, Mirko
    Miani, Alessandro
    de Gennaro, Gianluigi
    ENVIRONMENTAL RESEARCH, 2021, 202
  • [9] Mitigating airborne transmission of SARS-CoV-2
    Addleman, Sarah
    Leung, Victor
    Asadi, Leyla
    Sharkawy, Abdu
    McDonald, Jennifer
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2021, 193 (26) : E1010 - E1011
  • [10] Mitigating airborne transmission of SARS-CoV-2
    Addleman, Sarah
    Leung, Victor
    Asadi, Leyla
    Sharkawy, Abdu
    McDonald, Jennifer
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2021, 193 (31) : E1234 - E1236