Electrocoagulation treatment of furniture industry wastewater

被引:4
|
作者
Vicente, Carolina [1 ]
Silva, Joao R. [1 ,2 ]
Santos, Andreia D. [1 ,2 ]
Silva, Joao F. [1 ]
Mano, Jorge T. [3 ]
Castro, Luis M. [1 ,2 ,4 ]
机构
[1] Polytech Coimbra, Coimbra Inst Engn, Dept Chem & Biol Engn, Rua Pedro Nunes Quinta Nora, P-3030199 Coimbra, Portugal
[2] Univ Coimbra, Fac Sci & Technol, CIEPQPF Chem Engn Proc & Forest Prod Res Ctr, Dept Chem Engn, Rua Silvio Lima, P-3030790 Coimbra, Portugal
[3] IKEA Ind Portugal SA, Ave Capital Movel 157, P-4595282 Penamaior, Portugal
[4] Coimbra Inst Engn, Dept Chem & Biol Engn, SISus Lab Sustainable Ind Syst, Coimbra Inst Engn, Rua Pedro Nunes Quinta Nora, P-3030199 Coimbra, Portugal
关键词
Alternating pulsed current; Electrocoagulation; Furniture industry; Iron quantification; Wastewater treatment; ALTERNATING PULSE CURRENT; POLYVINYL-ALCOHOL; EFFICIENCY; REMOVAL; IRON; DEGRADATION; PERFORMANCE; TEXTILE; EC; BIODEGRADATION;
D O I
10.1016/j.chemosphere.2023.138500
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Electrocoagulation was investigated as a method for treating wastewater containing polyvinyl acetate (PVAc) from the furniture industry. The study evaluated the evolution of iron concentration and passivation during the treatment process. Laboratory-scale experiments were conducted to evaluate the effects of inter-electrode distance (d), current density, and mode on treatment performance. Three values of d (0.3, 0.6, and 0.9 cm) were studied and found to have no significant effect on performance. However, lower d values resulted in reduced energy consumption due to a decrease in applied voltage. Three values of current density (132, 158, and 197 A m- 2) were studied under two current modes, Direct Current (DC) and Alternating Pulsed Current (APC). The best treatment performance for DC occurred under 158 A m- 2 (the treated wastewater was characterized by pH = 4.59 +/- 0.02, conductivity = 996 +/- 21 mu S cm- 1, COD = 1940 +/- 55 mgO2 L-1, TSS = 105 +/- 14 mg L-1, and Fe = 50.39 +/- 1.87 mgFe L-1). For APC, the best performance was achieved under 197 A m- 2 (the treated wastewater was characterized by pH = 6.33 +/- 0.06, conductivity = 988 +/- 17 mu S cm- 1, COD = 1942 +/- 312 mgO2 L-1, TSS = 199 +/- 55 mg L-1, and Fe = 44.68 +/- 4.60 mgFe L-1). Despite the promising results, treatment performance was insufficient to meet the legal requirements for water discharge. APC was found to be a more economically viable approach, as it reduced anode wear, electrode passivation, and energy consumption. The quantity of iron released increased with d, and the effect of current density on iron concentration was found to be non-linear. However, applying APC reduced the iron content for all tested current densities. The tests showed that EC was effective in removing chemical oxygen demand (COD) and total suspended solids (TSS), achieving removal efficiencies above 92% and 99%, respectively. However, the studied treatment procedures were insufficient to meet the EU legal requirements for water discharge. Therefore, the obtained wastewater should undergo a posttreatment process.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Pharmaceutical Industry Wastewater Treatment through Electrocoagulation
    Miron, Alexandra Raluca
    Chivu, Ana-Maria Andreea
    Rikabi, Abbas Abdul Kadhim Klaif
    Albu, Paul Constantin
    [J]. REVISTA DE CHIMIE, 2014, 65 (12): : 1399 - 1406
  • [2] Pharmaceutical Industry Wastewater Treatment by Electrocoagulation and Miceliar Ultrafiltration
    Albu, Paul Constantin
    Al Ani, Hussam Nadum Abdalraheem
    Cimbru, Anca Maria
    Popa, George Alexandru
    Niculae, Alexandra Gabriela
    Miron, Alexandra Raluca
    [J]. REVISTA DE CHIMIE, 2016, 67 (04): : 813 - 820
  • [3] Dairy industry wastewater electrocoagulation
    Lopez, Pamela
    Harnisth, Antonio
    [J]. ENFOQUE UTE, 2016, 7 (01): : 13 - 21
  • [4] Paper industry wastewater treatment by electrocoagulation and aspect of sludge management
    Kumar, Dushyant
    Sharma, Chhaya
    [J]. JOURNAL OF CLEANER PRODUCTION, 2022, 360
  • [5] Electrocoagulation using zinc electrodes for dairy industry wastewater treatment
    Silva Valente, Gerson de Freitas
    Santos Mendonca, Regina Celia
    Felix, Leonardo Bonato
    [J]. DESALINATION AND WATER TREATMENT, 2020, 206 : 58 - 65
  • [6] Electrocoagulation in Wastewater Treatment
    Butler, Erick
    Hung, Yung-Tse
    Yeh, Ruth Yu-Li
    Al Ahmad, Mohammed Suleiman
    [J]. WATER, 2011, 3 (02): : 495 - 525
  • [7] Advanced oxidation-based treatment of furniture industry wastewater
    Tichonovas, Martynas
    Krugly, Edvinas
    Grybauskas, Arturas
    Jankunaite, Dalia
    Racys, Viktoras
    Martuzevicius, Dainius
    [J]. ENVIRONMENTAL TECHNOLOGY, 2018, 39 (17) : 2215 - 2222
  • [8] Electrocoagulation of wastewater from almond industry
    Valero, David
    Ortiz, Juan M.
    Garcia, Vicente
    Exposito, Eduardo
    Montiel, Vicente
    Aldaz, Antonio
    [J]. CHEMOSPHERE, 2011, 84 (09) : 1290 - 1295
  • [9] Treatment of Beverage Industry Wastewater using a Combination of Electrocoagulation and Adsorption Processes
    Muryanto, Muryanto
    Marlina, Elin
    Sari, Ajeng Arum
    Harimawan, Achmad
    Sudarno, Sudarno
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON APPLIED CHEMISTRY 2018, 2018, 2024
  • [10] Treatment of dairy industry wastewater by combined aerated electrocoagulation and phytoremediation process
    Akansha, J.
    Nidheesh, P. V.
    Gopinath, Ashitha
    Anupama, K. V.
    Kumar, M. Suresh
    [J]. CHEMOSPHERE, 2020, 253