Structural Damage Detection Technique of Secondary Building Components Using Piezoelectric Sensors

被引:6
|
作者
Suzuki, Atsushi [1 ]
Liao, Wang [2 ]
Shibata, Daiki [3 ]
Yoshino, Yuki [4 ]
Kimura, Yoshihiro [1 ]
Shimoi, Nobuhiro [5 ]
机构
[1] Tohoku Univ, Grad Sch Engn, Sendai 9808577, Japan
[2] Shanghai Invest Design & Res Inst Co Ltd, Shanghai 200434, Peoples R China
[3] Tohoku Univ, Sch Engn, Sendai 9808577, Japan
[4] Natl Inst Technol, Sendai Coll, Sendai 0150055, Japan
[5] Akita Prefectural Univ, Fac Syst Sci & Technol, Yurihonjyo 0150055, Japan
关键词
concrete slab; damage detection; folded roof plate; piezoelectric sensor; structural health monitoring; CONCRETE COMPOSITE BEAMS; RIB SHEAR CONNECTORS; BEHAVIOR; DOWELS; CAPACITIES;
D O I
10.3390/buildings13092368
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With demand for the long-term continued use of existing building facilities, structural health monitoring and damage detection are attracting interest from society. Sensors of various types have been practically applied in the industry to satisfy this need. Among the sensors, piezoelectric sensors are an extremely promising technology by virtue of their cost advantages and durability. Although they have been used in aerospace and civil engineering, their application for building engineering remains limited. Remarkably, recent catastrophic seismic events have further reinforced the necessity of rapid damage detection and quick judgment about the safe use of facilities. Faced with these circumstances, this study was conducted to assess the applicability of piezoelectric sensors to detect damage to building components stemming from concrete cracks and local buckling. Specifically, this study emphasizes structural damage caused by earthquakes. After first applying them to cyclic loading tests to composite beam component specimens and steel frame subassemblies with a folded roof plate, the prospective damage positions were also found using finite element analysis. Crack propagation and buckling locations were predicted adequately. The piezoelectric sensors provided output when the concrete slab showed tensile cracks or when the folded roof plate experienced local buckling. Furthermore, damage expansion and progression were detected multiple times during loading tests. Results showed that the piezoelectric sensors can detect the structural damage of building components, demonstrating their potential for use in inexpensive and stable monitoring systems.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Structural damage identification using piezoelectric sensors
    Hu, N
    Fukunaga, H
    ADVANCED NONDESTRUCTIVE EVALUATION FOR STRUCTURAL AND BIOLOGICAL HEALTH MONITORING, 2001, 4335 : 371 - 382
  • [2] Structural damage identification using piezoelectric sensors
    Fukunaga, H
    Hu, N
    Chang, FK
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2002, 39 (02) : 393 - 418
  • [3] Structural Damage Detection with Piezoelectric Wafer Active Sensors
    Giurgiutiu, Victor
    9TH INTERNATIONAL CONFERENCE ON DAMAGE ASSESSMENT OF STRUCTURES (DAMAS 2011), 2011, 305
  • [4] Linear classification of system poles for structural damage detection using piezoelectric active sensors
    Lynch, JP
    SMART STRUCTURES AND MATERIALS 2004: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS, 2004, 5391 : 9 - 20
  • [5] Structural Damage Detection in a Steel Column-Beam Joint Using Piezoelectric Sensors
    Cuadra, Carlos H.
    Shimoi, Nobuhiro
    2018 18TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2018, : 1250 - 1253
  • [6] Structural Health Monitoring and Damage Detection with Piezoelectric Wafer Active Sensors
    Giurgiutiu, Victor
    DYNAMICS FOR SUSTAINABLE ENGINEERING, VOL 1, 2011, : 329 - 337
  • [7] Structural damage detection research using piezoelectric patch array
    2000, Sichuan Institute of Piezoelectric and Acoustooptic Technology, China (22):
  • [8] Structural monitoring sensors detect damage on components
    不详
    ADVANCED MATERIALS & PROCESSES, 2007, 165 (09): : 22 - 22
  • [9] Structural damage detection using information fusion technique
    Guo, HY
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2006, 20 (05) : 1173 - 1188
  • [10] Guided wave propagation and damage detection in composite pipes using piezoelectric sensors
    Gresil, Matthieu
    Poohsai, Adisorn
    Chandarana, Neha
    STRUCTURAL HEALTH MONITORING - FROM SENSING TO DIAGNOSIS AND PROGNOSIS, 2017, 188 : 148 - 155