Optimization analysis of Organic Rankine Cycle powered by waste heat of a supermarket transcritical CO2 multi-ejector refrigeration cycle

被引:7
|
作者
Tsimpoukis, Dimitrios [1 ,2 ]
Syngounas, Evangelos [1 ]
Bellos, Evangelos [3 ]
Koukou, Maria [4 ]
Tzivanidis, Christos [3 ]
Anagnostatos, Stavros [2 ,5 ]
Vrachopoulos, Michail Gr [4 ]
机构
[1] Natl & Kapodistrian Univ Athens, Core Dept, Energy & Environm Res Lab, Psachna, Greece
[2] METRO SA, Energy Environm & Facil Dept, Head Dept Dev, Athens, Greece
[3] Natl Tech Univ Athens, Sch Mech Engn, Thermal Dept, Athens, Greece
[4] Natl & Kapodistrian Univ Athens, Dept Agr Dev, Agrofood & Management Nat Resources, Psachna, Greece
[5] Natl Tech Univ Athens, Sch Elect Engn, Elect Power Dept, Athens, Greece
关键词
Refrigeration; Power production; ORC; Waste heat; CO2; PERFORMANCE; RECOVERY; ENERGY; ORC;
D O I
10.1016/j.jclepro.2023.138106
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The exploitation of low-grade heat sources that are available from existing thermal systems processes consists a promising concept for the production of energy. In this research, the integration of an Organic Rankine Cycle (ORC) unit on a supermarket transcritical CO2 refrigeration system with ejectors is investigated, which is supplied with low-grade heat by the common discharge of the compressors. The optimization analysis proves that for different combinations of CO2 temperature and pressure in the ORC evaporator, as well as for different ORC condensation temperatures, there is a different optimum ORC evaporation temperature that leads to the highest energy production. Concerning the annual performance analysis conducted for the city of Athens, Greece, operation with isopentane is found to provide the greatest energy production with 10.36 MWh annually, which corresponds to a 3.69% reduction in the refrigeration system's energy consumption. For operation under the ambient temperature of 40 degrees C, the corresponding reduction of the refrigeration system consumption due to the presence of ORC is 7.54%. Finally, the financial analysis reveals that toluene is the most advantageous solution, leading to a payback period of 3.9 years, with a net present value by the end of the project's lifetime equal to 34.32 keuro.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Calculation and analysis on transcritical ejector refrigeration cycle with CO2
    Wang, Fei
    Yang, Yong
    Shen, Shengqiang
    [J]. Huagong Xuebao/CIESC Journal, 2013, 64 (07): : 2400 - 2404
  • [2] Thermodynamic analysis of transcritical CO2 refrigeration cycle with an ejector
    Sun Fangtian
    Ma Yitai
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (6-7) : 1184 - 1189
  • [3] Incorporation of an organic Rankine cycle in a transcritical booster CO2 refrigeration system
    Bellos, Evangelos
    Tzivanidis, Christos
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (10) : 7964 - 7988
  • [4] Performance Analysis and Comprehensive Evaluation of Solar Organic Rankine Cycle Combined with Transcritical CO2 Refrigeration Cycle
    Zhang, Na
    Xu, Po
    Wang, Yiming
    Tong, Wencai
    Yang, Zhao
    [J]. ENERGIES, 2023, 16 (14)
  • [5] Particular characteristics of transcritical CO2 refrigeration cycle with an ejector
    Deng, Jian-qiang
    Jiang, Pei-xue
    Lu, Tao
    Lu, Wei
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) : 381 - 388
  • [6] Thermodynamic evaluation of CO2 transcritical refrigeration cycle with ejector
    Khellaf, Nabil
    Gomri, Rabah
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2016, 19 (02) : 210 - 231
  • [7] Theoretical Study on CO2 Transcritical Cycle Combined Ejector Cycle Refrigeration System
    卢苇
    马一太
    李敏霞
    查世彤
    [J]. Transactions of Tianjin University, 2003, (04) : 316 - 320
  • [8] Performance characteristics of ejector expander transcritical CO2 refrigeration cycle
    Ersoy, H. Kursad
    Bilir, Nagihan
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2012, 226 (A5) : 623 - 635
  • [9] Transcritical CO2 refrigeration cycle with ejector-expansion device
    Li, DQ
    Groll, EA
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (05): : 766 - 773
  • [10] Optimization of ejector-expansion transcritical CO2 heat pump cycle
    Sarkar, Jahar
    [J]. ENERGY, 2008, 33 (09) : 1399 - 1406