Focusing on summer setpoint temperature to intensify PCM effectiveness in building: energy saving in Jeddah climate

被引:11
|
作者
Khetib, Yacine [1 ,2 ]
Alotaibi, Abdullah Alhumaidi [3 ]
Alshahri, Abdullah H. [4 ]
Kalbasi, Rasool
Sajadi, S. Mohammad [5 ,6 ]
Sharifpur, Mohsen [7 ,8 ]
机构
[1] King Abdulaziz Univ, Fac Engn, Mech Engn Dept, Jeddah, Saudi Arabia
[2] King Abdulaziz Univ, Ctr Res Excellence Renewable Energy & Power Syst, Jeddah, Saudi Arabia
[3] Taif Univ, Coll Ranyah, Dept Sci & Technol, At Taif, Saudi Arabia
[4] Taif Univ, Coll Engn, Civil Engn Dept, At Taif, Saudi Arabia
[5] Cihan Univ Erbil, Dept Nutr, Erbil, Kurdistan Regio, Iraq
[6] Soran Univ, Dept Phytochem, KRG, SRC, Soran, Iraq
[7] Univ Pretoria, Dept Mech & Aeronaut Engn, Pretoria, South Africa
[8] China Med Univ, China Med Univ Hosp, Dept Med Res, Taichung, Taiwan
关键词
Building; energy saving; PCM; setpoint; summer; thermal resistance; PHASE-CHANGE MATERIAL; HEAT-TRANSFER; PERFORMANCE; ELECTRICITY; SYSTEMS; COST;
D O I
10.1080/00986445.2021.1986031
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Considering the 66% share for cooling and 3% for building heating in Saudi Arabia, the effect of PCM on reducing energy consumption by focusing on summer setpoint temperatures (STsummer) was examined. A 2 cm layer of RT-25HC (22-26 degrees C) was added to the wall and ceiling with thermal resistances of 0.723 and 1.057 m(2).K/W. At STsummer=22 degrees C, RT-25HC resulted in an energy saving of 8.12 kWh/m(2). As STsummer increases to 25 degrees C, the energy saving reaches 55.54 kWh/m(2) (maximum value). A further increase in STsummer reduces energy saving to 39.69 kW (at 27 degrees C). In this study, the effects of RT-25HC thickness were also discussed and it was observed that thickness increasing had undesirable results. The presence of RT-25HC increases the thermal resistance, hence reduces the heat exchange, if PCM does not undergo the phase change. If RT-25HC has a phase change, increasing its thickness boots heat transfer which is not advantageous. However, at thickness 3 cm, RT-25HC is still useful, and under the best conditions, energy saving was 41.1 kWh/m(2).
引用
收藏
页码:908 / 919
页数:12
相关论文
共 50 条
  • [1] Energy saving in building with PCM cold storage
    Stritih, Uros
    Butala, Vincenc
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (15) : 1532 - 1544
  • [3] Usefulness of PCM in building applications focusing on envelope heat exchange - Energy saving considering two scenarios
    Kalbasi, Rasool
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 50
  • [4] Quantitative evaluation of thermal performance and energy saving potential of the building integrated with PCM in a subarctic climate
    Kenzhekhanov, Sultan
    Memon, Shazim Ali
    Adilkhanova, Indira
    [J]. ENERGY, 2020, 192
  • [5] Energy saving effect of building envelope in summer
    Hou-hua Wang
    Rui Guo
    Qiu-lian Xiao
    [J]. Journal of Central South University, 2012, 19 : 1370 - 1376
  • [6] Energy saving effect of building envelope in summer
    Wang Hou-hua
    Guo Rui
    Xiao Qiu-lian
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2012, 19 (05): : 1370 - 1376
  • [7] Energy saving effect of building envelope in summer
    王厚华
    郭锐
    肖秋连
    [J]. Journal of Central South University, 2012, 19 (05) : 1370 - 1376
  • [8] Sensitivity of energy performance to the selection of PCM melting temperature for the building located in Cfb climate zone
    Bozzhigitov, Abylaikhan
    Memon, Shazim Ali
    Adilkhanova, Indira
    [J]. ENERGY REPORTS, 2022, 8 : 6301 - 6320
  • [9] Experimental study of PCM-enhanced building envelope towards energy-saving and decarbonisation in a severe hot climate
    Al-Yasiri, Qudama
    Szabo, Marta
    [J]. ENERGY AND BUILDINGS, 2023, 279
  • [10] Energy-saving of building envelope using passive PCM technique: A case study of Kuwait City climate conditions
    Al-Rashed, Abdullah A. A. A.
    Alnaqi, Abdulwahab A.
    Alsarraf, Jalal
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 46