Sensitivity analyses of probabilistic and deterministic DTI tractography methodologies for studying arm muscle architecture

被引:1
|
作者
Joshi, Divya [1 ,2 ]
Sohn, M. Hongchul [1 ]
Dewald, Julius P. A. [1 ,2 ,3 ]
Murray, Wendy M. [1 ,2 ,3 ]
Ingo, Carson [1 ,4 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Phys Therapy & Human Movement Sci, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Evanston, IL USA
[3] Northwestern Univ, Feinberg Sch Med, Dept Phys Med & Rehabil, Chicago, IL 60611 USA
[4] Northwestern Univ, Feinberg Sch Med, Dept Neurol, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
deterministic; diffusion tensor imaging; muscle architecture; probabilistic; skeletal muscle; tractography; SKELETAL-MUSCLE; FIBER TRACTOGRAPHY; PENNATION ANGLE; DIFFUSION; NOISE; OPTIMIZATION; PARAMETERS; MOVEMENT; STRENGTH; TRACKING;
D O I
10.1002/mrm.29862
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the sensitivity profiles of probabilistic and deterministic DTI tractography methods in estimating geometric properties in arm muscle anatomy.Methods: Spin-echo diffusion-weighted MR images were acquired in the dominant arm of 10 participants. Both deterministic and probabilistic tractography were performed in two different muscle architectures of the parallel-structured biceps brachii (and the pennate-structured flexor carpi ulnaris. Muscle fascicle geometry estimates and number of fascicles were evaluated with respect to tractography turning angle, polynomial fitting order, and SNR. The DTI tractography estimated fascicle lengths were compared with measurements obtained from conventional cadaveric dissection and ultrasound modalities.Results: The probabilistic method generally estimated fascicle lengths closer to ranges reported by conventional methods than the deterministic method, most evident in the biceps brachii (p > 0.05), consisting of longer, arc-like fascicles. For both methods, a wide turning angle (50o-90 degrees) generated fascicle lengths that were in close agreement with conventional methods, most evident in the flexor carpi ulnaris (p > 0.05), consisting of shorter, feather-like fascicles. The probabilistic approach produced at least two times more fascicles than the deterministic approach. For both approaches, second-order fitting yielded about double the complete tracts as third-order fitting. In both muscles, as SNR decreased, deterministic tractography produced less fascicles but consistent geometry (p > 0.05), whereas probabilistic tractography produced a consistent number but altered geometry of fascicles (p < 0.001).Conclusion: Findings from this study provide best practice recommendations for implementing DTI tractography in skeletal muscle and will inform future in vivo studies of healthy and pathological muscle structure.
引用
收藏
页码:497 / 512
页数:16
相关论文
共 5 条
  • [1] Development of DTI Based Probabilistic Tractography Methods to Characterize Arm Muscle Architecture in Individuals Post Hemiparetic Stroke
    Joshi, Divya
    Dewald, Julius P. A.
    Ingo, Carson
    [J]. 2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 3451 - 3454
  • [2] Incorporating calibrated model parameters into sensitivity analyses: Deterministic and probabilistic approaches
    Taylor D.C.A.
    Pawar V.
    Kruzikas D.T.
    Gilmore K.E.
    Sanon M.
    Weinstein M.C.
    [J]. PharmacoEconomics, 2012, 30 (2) : 119 - 126
  • [3] Incorporating Calibrated Model Parameters into Sensitivity Analyses Deterministic and Probabilistic Approaches
    Taylor, Douglas C. A.
    Pawar, Vivek
    Kruzikas, Denise T.
    Gilmore, Kristen E.
    Sanon, Myrlene
    Weinstein, Milton C.
    [J]. PHARMACOECONOMICS, 2012, 30 (02) : 119 - 126
  • [4] INCORPORATING CALIBRATED MODEL PARAMETERS INTO SENSITIVITY ANALYSES: DETERMINISTIC AND PROBABILISTIC APPROACHES
    Taylor, D. C.
    Kruzikas, D.
    Pawar, V
    Gilmore, K.
    Naik, S.
    Weinstein, M. C.
    [J]. VALUE IN HEALTH, 2008, 11 (06) : A346 - A346
  • [5] Probabilistic cost-effectiveness analyses of long term management therapies for postmenopausal osteoporosis: Cautions and concerns of results obtained from traditional deterministic sensitivity analyses
    Goeree, R
    Blackhouse, G
    Adachi, J
    [J]. OSTEOPOROSIS INTERNATIONAL, 2003, 14 : S16 - S17