Itaconic Acid-Based Organic-Polymer Monolithic Column for Hydrophilic Capillary Electrochromatography and Its Application in Pharmaceutical Analysis

被引:2
|
作者
Mao, Zhenkun [1 ,2 ]
Chen, Jinxiu [1 ,2 ]
Jiang, Dandan [1 ,2 ]
Zhao, Ningmin [1 ,2 ]
Qin, Yinhui [1 ,2 ]
Mao, Xiangju [3 ]
Fang, Fengqin [1 ,2 ]
Ma, Peizhi [1 ,2 ]
机构
[1] Henan Prov Peoples Hosp, Dept Pharm, Zhengzhou 450003, Henan, Peoples R China
[2] Zhengzhou Univ, Peoples Hosp, Dept Pharm, Zhengzhou 450003, Henan, Peoples R China
[3] CAGS, Zhengzhou Inst Multipurpose Utilizat Mineral Resou, Zhengzhou 450006, Peoples R China
来源
ACS OMEGA | 2023年 / 9卷 / 01期
基金
中国国家自然科学基金;
关键词
STATIONARY-PHASE; SEPARATION; PROTEINS;
D O I
10.1021/acsomega.3c08031
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Itaconic acid is an excellent hydrophilic monomer owing to the dicarboxylic group possessing strong polarity. This study reports on the preparation of a new organic-polymer monolithic column poly-(itaconic acid-co-3-(acryloyloxy)-2-hydroxypropyl methacrylate) (poly-(IA-co-AHM)) featuring excellent hydrophilic chromatography ability and its application in pharmaceutical analysis. The monolithic column was successfully synthesized by using the monomer itaconic acid and the cross-linker AHM through an in situ copolymerization method. Optical microscopy, scanning electron microscopy (SEM), and Fourier transform infrared spectroscopy (FTIR) were employed for the characterization of the poly-(IA-co-AHM) monolithic column, and all of these demonstrated that the prepared itaconic acid-based monolithic column exhibited satisfactory permeability and a homogeneous porous structure. Owing to the carboxylic groups of itaconic acid, a cathodic electroosmotic flow (EOF) was generated on the itaconic acid-based monolithic column among the pH ranges of the mobile phase from 4.0 to 9.0. Depending on the powerful hydrophilic interactions, different kinds of polar substances, including thioureas, nucleoside drugs, sulfonamides, and polypeptides, were separated efficiently by the itaconic acid-based monoliths poly-(IA-co-AHM). The separations of polar compounds were successfully realized, even at a lower level of 50% acetonitrile content on this monolithic column. The highest column efficiencies corresponding to N,N '-dimethylthiourea and idoxuridine were 102 720 and 124 267 N/m, respectively. The poly-(IA-co-AHM) monolithic column displayed excellent repeatability, whose relative standard deviations (RSDs) of the retention time and peak area were both lower than 5.0%. All experimental results demonstrated that the new itaconic acid-functionalized monolithic column was greatly appropriate to separate the polar compounds under the HILIC mode.
引用
收藏
页码:1554 / 1561
页数:8
相关论文
共 50 条
  • [1] Strong hydrophilic monolithic column functionalized with amphiphilic benzyl quinine for capillary electrochromatography and application in pharmaceutical analysis
    Mao, Zhenkun
    Li, Zhentao
    Hu, Changjun
    Liu, Yikun
    Cao, Zhi
    Chen, Zilin
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1621
  • [2] Preparation of Methacrylic Acid-based Monolithic Column for Capillary Electrochromatography by Photopolymerization
    Zuo Guo-Qiang
    Wu Ling-Li
    Li Quan-Min
    Zhang Yu-Ping
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (09) : 1233 - 1237
  • [3] Cinnamic acid polymer-based monolithic column for capillary electrochromatography
    Yan, WY
    Gao, RY
    Zhang, ZC
    Yan, C
    Wang, QS
    CHROMATOGRAPHIA, 2003, 57 (11-12) : 819 - 823
  • [4] Cinnamic acid polymer-based monolithic column for capillary electrochromatography
    Weiying Yan
    Ruyu Gao
    Zhichao Zhang
    Chao Yan
    Qinsun Wang
    Chromatographia, 2003, 57 : 819 - 823
  • [5] A benzenesulfonic acid-modified organic polymer monolithic column with reversed-phase/hydrophilic bifunctional selectivity for capillary electrochromatography
    Liu, Yikun
    He, Ning
    Lu, Yingfang
    Li, Weiqiang
    He, Xin
    Li, Zhentao
    Chen, Zilin
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2023, 13 (02) : 209 - 215
  • [6] Preparation of hydrophilic interaction monolithic column and its application in the analysis of melamine in dairy products using pressurized capillary electrochromatography
    Li Xinyan
    Wang Yan
    Gu Xue
    Chen Yan
    Yan Chao
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (03) : 231 - 235
  • [7] Preparation and evaluation of a polymethacrylate based monolithic column for hydrophilic interaction capillary electrochromatography
    Huang Guihua
    Chen Sijin
    Lin Xucong
    Xie Zenghong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (12) : 1173 - 1178
  • [8] Preparation of phosphorylcholine-based hydrophilic monolithic column and application for analysis of drug-related impurities with capillary electrochromatography
    Qiu, Danye
    Li, Feng
    Zhang, Mingyu
    Kang, Jingwu
    ELECTROPHORESIS, 2016, 37 (12) : 1725 - 1732
  • [9] Simultaneous Determination of Five Alkaloid Compounds in a Drug Based on a Hydrophilic Monolithic Column by Capillary Electrochromatography
    Chen, Zongbao
    Ye, Qing
    Liu, Linghai
    Dong, Hongxia
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (01) : 88 - 95
  • [10] Ionic liquid-based zwitterionic organic polymer monolithic column for capillary hydrophilic interaction chromatography
    Wang, Tingting
    Chen, Yihui
    Ma, Junfeng
    Zhang, Xiaodan
    Zhang, Lihua
    Zhang, Yukui
    ANALYST, 2015, 140 (16) : 5585 - 5592