Weakly supervised learning-based 3D bladder reconstruction from 2D ultrasound images for bladder volume measurement

被引:0
|
作者
Peng, Zhao [1 ,2 ]
Shan, Hongming [3 ,4 ,5 ]
Yang, Xiaoyu [1 ,2 ]
Li, Shuzhou [1 ,2 ]
Tang, Du [1 ,2 ]
Cao, Ying [1 ,2 ]
Shao, Qigang [1 ,2 ]
Huo, Wanli [6 ]
Yang, Zhen [1 ,2 ,7 ]
机构
[1] Cent South Univ, Xiangya Hosp, Dept Oncol, Changsha, Peoples R China
[2] Cent South Univ, Xiangya Hosp, Natl Clin Res Ctr Geriatr Disorders, Changsha, Peoples R China
[3] Fudan Univ, Inst Sci & Technol Brain inspired Intelligence, Shanghai, Peoples R China
[4] Fudan Univ, MOE Frontiers Ctr Brain Sci, Shanghai, Peoples R China
[5] Shanghai Ctr Brain Sci & Brain inspired Technol, Shanghai, Peoples R China
[6] China Jiliang Univ, Coll Informat Engn, Key Lab Electromagnet Wave Informat Technol & Metr, Hangzhou, Peoples R China
[7] Cent South Univ, Xiangya Hosp, Dept Oncol, 87 Xiangya Rd, Changsha, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
3D bladder reconstruction; bladder volume; compactness loss; ultrasound images; weakly supervised learning; ACCURACY; SCANNER; SEGMENTATION; PRECISION;
D O I
10.1002/mp.16638
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundAccurate measurement of bladder volume is necessary to maintain the consistency of the patient's anatomy in radiation therapy for pelvic tumors. As the diversity of the bladder shape, traditional methods for bladder volume measurement from 2D ultrasound have been found to produce inaccurate results. PurposeTo improve the accuracy of bladder volume measurement from 2D ultrasound images for patients with pelvic tumors. MethodsThe bladder ultrasound images from 130 patients with pelvic cancer were collected retrospectively. All data were split into a training set (80 patients), a validation set (20 patients), and a test set (30 patients). A total of 12 transabdominal ultrasound images for one patient were captured by automatically rotating the ultrasonic probe with an angle step of 15 & DEG;. An incomplete 3D ultrasound volume was synthesized by arranging these 2D ultrasound images in 3D space according to the acquisition angles. With this as input, a weakly supervised learning-based 3D bladder reconstruction neural network model was built to predict the complete 3D bladder. The key point is that we designed a novel loss function, including the supervised loss of bladder segmentation in the ultrasound images at known angles and the compactness loss of the 3D bladder. Bladder volume was calculated by counting the number of voxels belonging to the 3D bladder. The dice similarity coefficient (DSC) was used to evaluate the accuracy of bladder segmentation, and the relative standard deviation (RSD) was used to evaluate the calculation accuracy of bladder volume with that of computed tomography (CT) images as the gold standard. ResultsThe results showed that the mean DSC was up to 0.94 and the mean absolute RSD can be reduced to 6.3% when using 12 ultrasound images of one patient. Further, the mean DSC also was up to 0.90 and the mean absolute RSD can be reduced to 9.0% even if only two ultrasound images were used (i.e., the angle step is 90 & DEG;). Compared with the commercial algorithm in bladder scanners, which has a mean absolute RSD of 13.6%, our proposed method showed a considerably huge improvement. ConclusionsThe proposed weakly supervised learning-based 3D bladder reconstruction method can greatly improve the accuracy of bladder volume measurement. It has great potential to be used in bladder volume measurement devices in the future.
引用
收藏
页码:1277 / 1288
页数:12
相关论文
共 50 条
  • [1] 3D Kidney Reconstruction from 2D Ultrasound Images
    Teresa Alvarez-Gutierrez, Mariana
    Rodrigo Mejia-Rodriguez, Aldo
    Alejandro Cruz-Guerrero, Ines
    Roman Arce-Santana, Edgar
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 393 - 400
  • [2] Research on 3D Face Reconstruction Based on Weakly Supervised Learning
    Su, Zewei
    Dong, Lanfang
    Ji, Xuejie
    Li, Guoming
    Zhu, Xierong
    SOCIAL ROBOTICS, ICSR 2022, PT I, 2022, 13817 : 440 - 450
  • [3] 3D reconstruction of a carotid bifurcation from 2D transversal ultrasound images
    Yeom, Eunseop
    Nam, Kweon-Ho
    Jin, Changzhu
    Paeng, Dong-Guk
    Lee, Sang-Joon
    ULTRASONICS, 2014, 54 (08) : 2184 - 2192
  • [4] Deep Learning-Based Reconstruction of 3D Morphology of Geomaterial Particles from Single-View 2D Images
    Zhao, Jiangpeng
    Xie, Heping
    Li, Cunbao
    Liu, Yifei
    MATERIALS, 2024, 17 (20)
  • [5] The presentation of a semi-supervised deep learning platform for 3D face reconstruction from 2D images
    Hao, Bianyuan
    JOURNAL OF OPTICS-INDIA, 2024, 53 (03): : 2202 - 2211
  • [6] The presentation of a semi-supervised deep learning platform for 3D face reconstruction from 2D images
    Hao, Bianyuan
    JOURNAL OF OPTICS-INDIA, 2024, 53 (03): : 2202 - 2211
  • [7] 3D shape reconstruction from 2D images
    Hirano, Daisuke
    Funayama, Yusuke
    Maekawa, Takashi
    Computer-Aided Design and Applications, 2009, 6 (05): : 701 - 710
  • [8] MEASUREMENT OF BLADDER VOLUME WITH USE OF 3D US
    RICCABONA, M
    NELSON, TR
    PRETORIUS, DH
    DAVIDSON, TE
    RADIOLOGY, 1995, 197 : 435 - 436
  • [9] Reconstruction of 3D Microstructures from 2D Images via Transfer Learning
    Bostanabad, Ramin
    COMPUTER-AIDED DESIGN, 2020, 128
  • [10] 3D Surface Reconstruction of Spinal Ultrasound Images Based on 2D Contour Line
    Jiang, Wang
    Zhang, Junhua
    PROCEEDINGS OF THE 2016 3RD INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING, MANUFACTURING TECHNOLOGY AND CONTROL, 2016, 67 : 110 - 115