Decreasing complexity of glucose time series derived from continuous glucose monitoring is correlated with deteriorating glucose regulation

被引:7
|
作者
Li, Cheng [1 ]
Ma, Xiaojing [1 ]
Lu, Jingyi [1 ]
Tao, Rui [2 ]
Yu, Xia [2 ]
Mo, Yifei [1 ]
Lu, Wei [1 ]
Bao, Yuqian [1 ]
Zhou, Jian [1 ]
Jia, Weiping [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Diabet Inst, Shanghai Clin Ctr Diabet, Dept Endocrinol & Metab,Sch Med,Peoples Hosp 6,Sha, Shanghai 200233, Peoples R China
[2] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Peoples R China
基金
中国国家自然科学基金;
关键词
complexity of glucose time series; continuous glucose monitoring; impaired glucose regulation; insulin secretion and sensitivity; refined composite multi-scale entropy; BETA-CELL FUNCTION; FLUCTUATIONS; TOLERANCE; DYNAMICS;
D O I
10.1007/s11684-022-0955-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Most information used to evaluate diabetic statuses is collected at a special time-point, such as taking fasting plasma glucose test and providing a limited view of individual's health and disease risk. As a new parameter for continuously evaluating personal clinical statuses, the newly developed technique "continuous glucose monitoring " (CGM) can characterize glucose dynamics. By calculating the complexity of glucose time series index (CGI) with refined composite multi-scale entropy analysis of the CGM data, the study showed for the first time that the complexity of glucose time series in subjects decreased gradually from normal glucose tolerance to impaired glucose regulation and then to type 2 diabetes (P for trend < 0.01). Furthermore, CGI was significantly associated with various parameters such as insulin sensitivity/secretion (all P < 0.01), and multiple linear stepwise regression showed that the disposition index, which reflects beta-cell function after adjusting for insulin sensitivity, was the only independent factor correlated with CGI (P < 0.01). Our findings indicate that the CGI derived from the CGM data may serve as a novel marker to evaluate glucose homeostasis.
引用
收藏
页码:68 / 74
页数:7
相关论文
共 50 条
  • [1] Decreasing complexity of glucose time series derived from continuous glucose monitoring is correlated with deteriorating glucose regulation
    Cheng Li
    Xiaojing Ma
    Jingyi Lu
    Rui Tao
    Xia Yu
    Yifei Mo
    Wei Lu
    Yuqian Bao
    Jian Zhou
    Weiping Jia
    Frontiers of Medicine, 2023, 17 (01) : 68 - 74
  • [2] Decreasing complexity of glucose time series derived from continuous glucose monitoring is correlated with deteriorating glucose regulation
    Cheng Li
    Xiaojing Ma
    Jingyi Lu
    Rui Tao
    Xia Yu
    Yifei Mo
    Wei Lu
    Yuqian Bao
    Jian Zhou
    Weiping Jia
    Frontiers of Medicine, 2023, 17 : 68 - 74
  • [3] Continuous Glucose Monitoring Time Series Data Analysis: A Time Series Analysis Package for Continuous Glucose Monitoring Data
    Shao, Jian
    Liu, Ziqing
    Li, Shaoyun
    Wu, Benrui
    Nie, Zedong
    Li, Yuefei
    Zhou, Kaixin
    JOURNAL OF COMPUTATIONAL BIOLOGY, 2023, 30 (01) : 112 - 116
  • [4] Glucose concentration can be predicted ahead in time from continuous glucose monitoring sensior time-series
    Sparacino, Giovanni
    Zanderigo, Francesca
    Corazza, Stefano
    Maran, Alberto
    Facchinetti, Andrea
    Cobelli, Claudio
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (05) : 931 - 937
  • [5] Postprandial Peak Identification from Continuous Glucose Monitoring Time Series
    Archavli, Aikaterini
    Randeva, Harpal
    Khovanova, Natasha
    MEDICON 2023 AND CMBEBIH 2023, VOL 1, 2024, 93 : 96 - 107
  • [6] Applications of Variability Analysis Techniques for Continuous Glucose Monitoring Derived Time Series in Diabetic Patients
    Kohnert, Klaus-Dieter
    Heinke, Peter
    Vogt, Lutz
    Augstein, Petra
    Salzsieder, Eckhard
    FRONTIERS IN PHYSIOLOGY, 2018, 9
  • [7] Accuracy of real-time glucose values using continuous glucose monitoring:: the Guardian™ II continuous glucose monitoring system
    Schwartz, SL
    Buchea, O
    Shin, J
    Hoss, U
    Shah, R
    DIABETOLOGIA, 2004, 47 : A315 - A315
  • [8] Continuous subcutaneous glucose monitoring: good enough to use in glucose regulation protocols?
    Jack JM Ligtenberg
    Margo E de Plaa
    Jan G Zijlstra
    Critical Care, 15
  • [9] Continuous subcutaneous glucose monitoring: good enough to use in glucose regulation protocols?
    Ligtenberg, Jack J. M.
    de Plaa, Margo E.
    Zijlstra, Jan G.
    CRITICAL CARE, 2011, 15 (01):
  • [10] Safety of Glucose Regulation by the Bionic Pancreas without Continuous Glucose Monitoring Input
    Balliro, Courtney A.
    DIABETES, 2022, 71