A semi-automated robotic system for percutaneous interventions

被引:1
|
作者
Siegfarth, Marius [1 ]
Lutz, Raffael [1 ]
Iseke, Nils-Christian [1 ]
Moviglia, Javier [1 ]
Sadi, Fabian [1 ]
Stallkamp, Jan [1 ]
机构
[1] Heidelberg Univ, Mannheim Inst Intelligent Syst Med, Mannheim, Germany
关键词
Medical robotics; Interventional radiology; CT robot; Percutaneous intervention; CT;
D O I
10.1007/s11548-023-02882-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeA robotic assistive device is developed for needle-based percutaneous interventions. The aim is a hybrid system using both manual and actuated robotic operation in order to obtain a device that has a large workspace but can still fit in the gantry opening of a CT scanner. This will enable physicians to perform precise and time-efficient CT-guided percutaneous interventions. The concept of the mechanics and software of the device is presented in this work.MethodsThe approach is a semi-automated robotic assistive device, which combines manual and robotic positioning to reduce the number and size of necessary motors. The system consists of a manual rough positioning unit, a robotic fine positioning unit and an optical needle tracking unit. The resulting system has eight degrees of freedom, of which four are manual, which comprise encoders to monitor the position of each axis. The remaining four axes are actuated axes for fine positioning of the needle. Cameras are attached to the mechanical structure for 3D tracking of the needle pose. The software is based on open-source software, mainly ROS2 as robotic middleware, Moveit2 for trajectory calculation and 3D Slicer for needle path planning.ResultsThe communication between the components was successfully tested with a clinical CT scanner. In a first experiment, four needle insertions were planned and the deviation of the actual needle path from the planned path was measured. The mean deviation from the needle path to the target point was 21.9 mm, which is mainly caused both by translational deviation (15.4 mm) and angular deviation (6.8 degrees) of the needle holder. The optical tracking system was able to detect the needle position with a mean deviation of 3.9 mm.ConclusionThe first validation of the system was successful which proves that the proposed concept for both the hardware and software is feasible. In a next step, an automatic position correction based on the optical tracking system will be integrated, which is expected to significantly improve the system accuracy.
引用
收藏
页码:1571 / 1575
页数:5
相关论文
共 50 条
  • [1] A semi-automated robotic system for percutaneous interventions
    Marius Siegfarth
    Raffael Lutz
    Nils-Christian Iseke
    Javier Moviglia
    Fabian Sadi
    Jan Stallkamp
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 1571 - 1575
  • [2] Path Planning for Semi-automated Simulated Robotic Neurosurgery
    Lu, Danying
    Gong, Yuanzheng
    Hannaford, Blake
    Seibel, Eric J.
    [J]. 2015 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2015, : 2639 - 2645
  • [3] Integrated vision-based system for efficient, semi-automated control of a robotic manipulator
    Jiang, Hairong
    Wachs, Juan P.
    Duerstock, Bradley S.
    [J]. INTERNATIONAL JOURNAL OF INTELLIGENT COMPUTING AND CYBERNETICS, 2014, 7 (03) : 253 - 266
  • [4] Development of a low-cost semi-automated robotic orthophosphate system for batch analysis
    Mc Eleney, Christopher
    Bradley, Martin
    Alves, Sheila
    Mc Crudden, Denis
    [J]. ANALYTICAL METHODS, 2022, 14 (35) : 3444 - 3450
  • [5] INTRODUCTION OF A SEMI-AUTOMATED SYSTEM FOR BLOOD CULTURES
    YAGEV, Y
    SIMU, A
    ALKAN, M
    [J]. ISRAEL JOURNAL OF MEDICAL SCIENCES, 1984, 20 (05): : 475 - 475
  • [6] SEMI-AUTOMATED SYSTEM BENEFITS VETERAN HAULERS
    不详
    [J]. MANAGEMENT OF WORLD WASTES, 1985, 28 (04): : 96 - &
  • [7] A SEMI-AUTOMATED PORTABLE TSIVOGLOU COUNTING SYSTEM
    JENKINS, PH
    HAGEE, GR
    [J]. HEALTH PHYSICS, 1985, 49 (01): : 180 - 180
  • [8] SiteCity: A semi-automated site modelling system
    Hsieh, Y
    [J]. 1996 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1996, : 499 - 506
  • [9] A Semi-Automated System for Recognizing Prior Knowledge
    More, J.
    Conesa, J.
    Baneres, D.
    Junyent, M.
    [J]. INTERNATIONAL JOURNAL OF EMERGING TECHNOLOGIES IN LEARNING, 2015, 10 (07) : 23 - 30
  • [10] AUTOMATED AND SEMI-AUTOMATED PERIMETRY
    PRADINES, F
    DELBOSC, B
    ROYER, J
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 1985, 8 (02): : 173 - 185