Optimal allocation of hybrid energy storage capacity of DC microgrid based on model predictive control algorithm

被引:0
|
作者
Zhao, Jie [1 ]
Wang, Shuo [1 ]
Wu, Haotian [2 ]
机构
[1] Shijiazhuang Power Supply Co, State Grid Hebei Elect Power Co, Shijiazhuang 050000, Hebei, Peoples R China
[2] Shanghai Invest Design & Res Inst Co Ltd, Shanghai 200335, Peoples R China
关键词
DC microgrid; model predictive control; mixed energy storage; objective function; secondary planning;
D O I
10.3233/JIFS-234849
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
To effectively enhance the safety, stability, and economic operation capability of DC microgrids, an optimized control strategy for DC microgrid hybrid energy storage system (HESS)(The abbreviation table is shown in Table 2) based on model predictive control theory is proposed. Based on the characteristics of supercapacitors and batteries, system safety requirements, and various constraints, a predictive model for a hybrid energy storage DC microgrid is established. By defining its optimization indicators, designing an energy optimization management strategy, and transforming it into a quadratic programming problem for solution, the reasonable scheduling of power in the DC microgrid has been achieved. In addition, a power control method was proposed for the system without constraints. The simulation experiment results show that at the initial sampling time, the system operates normally, and the MPC algorithm allocates two types of energy storage devices to discharge to meet the net load demand, without absorbing electricity from the external network. At the 30th sampling point, the net load increases, and the MPC controller obtains the optimal solution of the control problem based on the known net load prediction data at the previous sampling time. It outputs the operating reference values of each output unit at the next time. Starting from the 100th to 199th sampling points, SOCUC falls below the lower limit of the safety interval, and the system enters situation 4 mode. The external network output assists the battery in working. At the 131st sampling point, the net load decreases, the system enters Situation 3 mode, and the battery operates independently. Until the 179th point, SOCB was also below the lower limit of its safety interval, and the system entered situation 5 mode, completely maintaining system power balance by external network power. Starting from point 201, the net load becomes negative, and the system charges the HESS according to instructions and stops the external power grid energy transmission. Conclusion: The feasibility and effectiveness of the proposed optimization management strategy have been verified.
引用
收藏
页码:12065 / 12077
页数:13
相关论文
共 50 条
  • [1] Energy management strategy of DC microgrid hybrid energy storage based on model predictive control
    Du X.
    Shen Y.
    Li J.
    Shen, Yanxia (shenyx@jiangnan.edu.cn), 1600, Power System Protection and Control Press (48): : 69 - 75
  • [2] Optimal Capacity Configuration of Hybrid Energy Storage for an Isolated Microgrid Based on QPSO Algorithm
    Xie, Xiaohan
    Wang, Hui
    Tian, Shanye
    Liu, Yaodong
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 2094 - 2099
  • [3] HIERARCHICAL DISTRIBUTED MODEL PREDICTIVE CONTROL FOR MULTIPLE HYBRID ENERGY STORAGE SYSTEMS IN A DC MICROGRID
    Yang, Weilin
    Zhao, Chaonan
    Hu, Guanyang
    Xu, Dezhi
    Pan, Tinglong
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2023, 19 (06): : 1735 - 1751
  • [4] Optimal Capacity and Cost Analysis of Hybrid Energy Storage System in Standalone DC Microgrid
    Boonraksa, Terapong
    Pinthurat, Watcharakorn
    Wongdet, Pinit
    Boonraksa, Promphak
    Marungsri, Boonruang
    Hredzak, Branislav
    IEEE ACCESS, 2023, 11 : 65496 - 65506
  • [5] Economic model predictive control for energy management in a hybrid storage microgrid
    Alarcon, Martin A.
    Alarcon, Rodrigo G.
    Gonzalez, Alejandro H.
    Ferramosca, Antonio
    2021 XIX WORKSHOP ON INFORMATION PROCESSING AND CONTROL (RPIC), 2021,
  • [6] Adaptive Power Allocation Strategy Based on Fuzzy Logic Algorithm for Hybrid Energy Storage System in DC Microgrid
    Yan L.
    Liu J.
    Shi M.
    Chen X.
    Wen J.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (09): : 2658 - 2669
  • [7] Power allocation scheme for grid interactive microgrid with hybrid energy storage system using model predictive control
    Jena, Chinmaya Jagdev
    Ray, Pravat Kumar
    JOURNAL OF ENERGY STORAGE, 2024, 81
  • [8] Hybrid Energy Storage Control of Microgrid Based on Adaptive Consistency Algorithm
    Yan Yao
    Kang Jiale
    Zhou Xuntian
    Zhang Zhigang
    Cen Yinwei
    2022 6TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY ENGINEERING, ICPEE, 2022, : 91 - 95
  • [9] Model Predictive Control Based DC Microgrid Virtual Inertia Optimal Method
    Zhao S.
    Wang H.
    Tian N.
    Meng J.
    Wang C.
    Tian Y.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (12): : 3264 - 3276
  • [10] Optimal allocation of wind power hybrid energy storage capacity based on ant colony optimization algorithm
    Zhao, Xin
    ENGINEERING OPTIMIZATION, 2024,