Improved Isothermal Relaxation Current Measurement Based on Isolated Circuit for Nondestructive Evaluation of High-Voltage Cable Insulation

被引:0
|
作者
Gu, Huangjing [1 ]
Zhang, Yongkang [1 ]
Shen, Bin [1 ]
Liu, Ziqi [1 ]
Zhou, Yunjie [1 ]
Wang, Xiaodi [1 ]
Zhu, Xinyang [2 ]
Wang, Yalin [2 ]
机构
[1] State Gid Shanghai Cable Co, Shanghai 200122, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Elect Informat & Elect Engn, Dept Elect Engn, Shanghai 200240, Peoples R China
关键词
high-voltage cable insulation; condition evaluation; non-destructive measurement; isothermal relaxation current; isolated circuit; SPACE-CHARGE; DIELECTRIC LOSS; XLPE CABLE; BEHAVIOR;
D O I
10.3390/en16237892
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Isothermal Relaxation Current (IRC) method, as a non-destructive condition evaluation method based on insulation dielectric response, has been applied in the maintenance of power cables. However, the relaxation current is usually conducted through the outer shield of the high-voltage wire, which will introduce the extra depolarization current into the test circuit, affecting the accuracy of the test results. Furthermore, most IRC cable measurements are single-phase, which means depolarization currents are measured for each cable separately. In order to improve the measurement accuracy and efficiency of the IRC test, this paper proposes an improved IRC measurement method based on an isolated circuit, which discharges the interference current from the high-voltage insulated wire back to the earth and reduces the measurement error of depolarization current. At the same time, a three-phase IRC simultaneous test system is designed, and the control software is developed. Furthermore, by verifying the accuracy of the test system, the independence of the single-phase circuit and the consistency of the three-phase circuit is achieved. The effect of depolarization time and temperature on the relaxation current is then explored to determine the suitable parameter of the IRC test. Finally, the IRC system is used to evaluate the aging state of 10 kV cables with various aging conditions in the air and water for the longest 12 months. Critical parameters such as aging factor and time constants are compared to investigate the aging characteristics of tested cables with various aging conditions in the air and water. The proposed method and research conclusions can provide helpful references for the non-destructive condition evaluation for high-voltage cable insulation.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] The Insulation Aging State Assessment of High Voltage Cable Based on the Isothermal Relaxation Current
    Liu, Heqian
    Li, Lin
    Zhang, Kexin
    Zhang, Hang
    Li, Zhongyuan
    Liang, Jianquan
    [J]. 2022 IEEE INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, BIG DATA AND ALGORITHMS (EEBDA), 2022, : 748 - 751
  • [3] Polypropylene-based ternary nanocomposites for recyclable high-voltage direct-current cable insulation
    Zhou, Yao
    Dang, Bin
    Wang, Haoming
    Liu, Jiping
    Li, Qi
    Hu, Jun
    He, Jinliang
    [J]. COMPOSITES SCIENCE AND TECHNOLOGY, 2018, 165 : 168 - 174
  • [4] Measurement of the harmonic distortion of the insulation loss current as a diagnostic tool for high voltage cable insulation
    Bulinski, AT
    So, E
    Bamji, SS
    [J]. 2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 1615 - 1620
  • [5] Conductivity-based model for the simulation of homocharges and heterocharges in XLPE high-voltage direct current cable insulation
    Joergens, Christoph
    Clemens, Markus
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (07) : 975 - 983
  • [6] IMPROVED FREE STRIPPING TAPE INSULATION SHIELD EPR INSULATED HIGH-VOLTAGE POWER CABLE
    SILVER, DA
    [J]. RUBBER AGE, 1974, 106 (09): : 51 - 51
  • [7] High-voltage Cable Insulation Online Monitoring in Coal Mine based on Pattern Recognition
    Zhao, Yongmei
    Li, Junfeng
    Wu, Lingjie
    Wang, Yanwen
    [J]. ADVANCES IN MATERIALS, MACHINERY, ELECTRONICS I, 2017, 1820
  • [8] Diagnosis and Location of High-voltage Cable Fault Based on Sheath Current
    He, Wen
    Li, Hao
    Tu, Jingyun
    Yang, Ting
    Meng, Jia
    Li, Hua
    Lin, Fuchang
    [J]. 2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3353 - 3359
  • [9] Trap Features of Retired High-Voltage XLPE Cable Insulation Material by Thermally Stimulated Depolarization Current
    Liao, Yanquan
    Zhang, Yunzhou
    Lu, Zhihua
    Luo, Pan
    Feng, Bing
    Xu, Man
    Xu, Yang
    [J]. 2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 772 - 775
  • [10] Performance evaluation of high-voltage circuit breakers by means of current zero analysis
    Smeets, RPP
    Kertész, V
    Nishiwaki, S
    Suzuki, K
    [J]. IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 424 - 429