Association between CZT-SPECT myocardial blood flow and coronary stenosis: A cross-sectional study

被引:0
|
作者
Fang, Zhang [1 ]
Cai, Wenyi [1 ]
Chen, Bei [1 ]
Li, Chunxiang [1 ]
Zhao, Jihong [1 ]
Tian, Zhiqiang [1 ]
Chen, Limei [1 ]
Bu, Ju [1 ]
Zhao, Zhongqiang [1 ,2 ]
Li, Dianfu [1 ,2 ]
机构
[1] Nanjing Med Univ, Peoples Hosp Jiangsu Prov, Affiliated Hosp 1, Dept Cardiol, Nanjing 210029, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Peoples Hosp Jiangsu Prov, Affiliated Hosp 1, Dept Cardiol, 300 Guangzhou Rd, Nanjing 210029, Jiangsu, Peoples R China
关键词
coronary heart disease; cadmium zinc telluride; single-photon emission computed tomography; myocardial perfusion imaging; coronary flow reserve; ARTERY-DISEASE; RESERVE; QUANTIFICATION; ANGIOGRAPHY;
D O I
10.3892/etm.2023.12049
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The association between the quantitative and semi-quantitative parameters of myocardial blood flow obtained using cadmium-zinc-telluride single photon emission computed tomography (CZT-SPECT) and coronary stenosis remains unclear. Therefore, the objective of the present study was to evaluate the diagnostic value of two parameters obtained using CZT-SPECT in patients with suspected or known coronary artery disease. A total of 24 consecutive patients who underwent CZT-SPECT and coronary angiography within 3 months of each other were included in the study. To evaluate the predictive ability of the regional difference score (DS), coronary flow reserve (CFR), and the combination thereof for positive coronary stenosis at the vascular level, receiver operating characteristic (ROC) curves were plotted and the area under the curves (AUCs) were calculated. Comparisons of the reclassification ability for coronary stenosis between different parameters were assessed by calculating the net reclassification index (NRI) and the integrated discrimination improvement (IDI). The 24 participants (median age: 65 years; range: 46-79 years; 79.2% male) included in this study had a total of 72 major coronary arteries. When stenosis >= 50% was defined as the criteria for positive coronary stenosis, the AUCs and the 95% confidence interval (CI) for regional DS, CFR, and the combination of the two indices were 0.653 (CI, 0.541-0.766), 0.731 (CI, 0.610-0.852) and 0.757 (CI, 0.645-0.869), respectively. Compared with single DS, the combination of DS and CFR increased the predictive ability for positive stenosis, with an NRI of 0.197-1.060 (P<0.01) and an IDI of 0.0150-0.1391 (P<0.05). When stenosis >= 75% was considered as the criteria, the AUCs were 0.760 (CI, 0.614-0.906), 0.703 (CI, 0.550-0.855), and 0.811 (CI, 0.676-0.947), respectively. Compared with DS, CFR had an IDI of -0.3392 to -02860 (P<0.05) and the combination of DS and CFR also enhanced the predictive ability, with an NRI of 0.0313-1.0758 (P<0.01). In conclusion, both regional DS and CFR had diagnostic values for coronary stenosis, but the diagnostic abilities differed in distinguishing between different degrees of stenosis, and the efficiency was improved with a combination of DS and CFR.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Impact of attenuation correction for CZT-SPECT measurement of myocardial blood flow
    Bailly, Matthieu
    Thibault, Frederique
    Courtehoux, Maxime
    Metrard, Gilles
    Ribeiro, Maria Joao
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) : 2560 - 2568
  • [2] Impact of attenuation correction for CZT-SPECT measurement of myocardial blood flow
    Matthieu Bailly
    Frédérique Thibault
    Maxime Courtehoux
    Gilles Metrard
    Maria Joao Ribeiro
    Journal of Nuclear Cardiology, 2021, 28 : 2560 - 2568
  • [3] Regadenoson versus dipyridamole: Evaluation of stress myocardial blood flow response on a CZT-SPECT camera
    Quentin Brana
    Frédérique Thibault
    Maxime Courtehoux
    Gilles Metrard
    Maria Joao Ribeiro
    Denis Angoulvant
    Matthieu Bailly
    Journal of Nuclear Cardiology, 2022, 29 : 113 - 122
  • [4] Regadenoson versus dipyridamole: Evaluation of stress myocardial blood flow response on a CZT-SPECT camera
    Brana, Quentin
    Thibault, Frederique
    Courtehoux, Maxime
    Metrard, Gilles
    Ribeiro, Maria Joao
    Angoulvant, Denis
    Bailly, Matthieu
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (01) : 113 - 122
  • [5] Integration of quantitative absolute myocardial blood flow estimates from dynamic CZT-SPECT improves the detection of coronary artery disease
    Fang-Shin Liu
    Shan-Ying Wang
    Yu-Chien Shiau
    Yen-Wen Wu
    Journal of Nuclear Cardiology, 2022, 29 : 2311 - 2321
  • [6] Integration of quantitative absolute myocardial blood flow estimates from dynamic CZT-SPECT improves the detection of coronary artery disease
    Liu, Fang-Shin
    Wang, Shan-Ying
    Shiau, Yu-Chien
    Wu, Yen-Wen
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (05) : 2311 - 2321
  • [7] A preliminary study of dobutamine myocardial flow reserve on 99mTc-Sestamibi CZT-SPECT
    Yan, Ming
    Shang, Hua
    Hao, Luping
    Guo, Xiaorui
    Zheng, Hongming
    Li, Hongmei
    Zhao, Yuchan
    ANNALS OF NUCLEAR MEDICINE, 2023, 37 (06) : 349 - 359
  • [8] A preliminary study of dobutamine myocardial flow reserve on 99mTc-Sestamibi CZT-SPECT
    Ming Yan
    Hua Shang
    Luping Hao
    Xiaorui Guo
    Hongming Zheng
    Hongmei Li
    Yuchan Zhao
    Annals of Nuclear Medicine, 2023, 37 : 349 - 359
  • [9] Quantification of myocardial blood flow by CZT-SPECT with motion correction and comparison with 15O-water PET
    Otaki, Yuka
    Manabe, Osamu
    Miller, Robert J. H.
    Manrique, Alain
    Nganoa, Catherine
    Roth, Nathaniel
    Berman, Daniel S.
    Germano, Guido
    Slomka, Piotr J.
    Agostini, Denis
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (04) : 1477 - 1486
  • [10] Quantification of myocardial blood flow by CZT-SPECT with motion correction and comparison with 15O-water PET
    Yuka Otaki
    Osamu Manabe
    Robert J. H. Miller
    Alain Manrique
    Catherine Nganoa
    Nathaniel Roth
    Daniel S. Berman
    Guido Germano
    Piotr J. Slomka
    Denis Agostini
    Journal of Nuclear Cardiology, 2021, 28 : 1477 - 1486