Comparison of sleep parameters from wrist-worn ActiGraph and Actiwatch devices

被引:4
|
作者
Liu, Fangyu [1 ]
Schrack, Jennifer A. [1 ,2 ]
Wanigatunga, Sarah K. [3 ]
Rabinowitz, Jill A. [3 ]
He, Linchen [3 ,4 ]
Wanigatunga, Amal A. [1 ,2 ]
Zipunnikov, Vadim [2 ,5 ]
Simonsick, Eleanor M. [6 ]
Ferrucci, Luigi [6 ]
Spira, Adam P. [2 ,3 ,7 ]
机构
[1] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Epidemiol, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Ctr Aging & Hlth, Baltimore, MD USA
[3] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Mental Hlth, Baltimore, MD USA
[4] Lehigh Univ, Coll Hlth, Dept Community & Populat Hlth, Bethlehem, PA USA
[5] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biostat, Baltimore, MD USA
[6] NIA, NIH, Baltimore, MD USA
[7] Johns Hopkins Sch Med, Dept Psychiat & Behav Sci, Baltimore, MD USA
关键词
accelerometers; sleep efficiency; sleep quality; deming regression; PHYSICAL-ACTIVITY; WAKE; POLYSOMNOGRAPHY; VALIDATION; VALIDITY; ADULTS;
D O I
10.1093/sleep/zsad155
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Sleep and physical activity, two important health behaviors, are often studied independently using different accelerometer types and body locations. Understanding whether accelerometers designed for monitoring each behavior can provide similar sleep parameter estimates may help determine whether one device can be used to measure both behaviors. Three hundred and thirty one adults (70.7 +/- 13.7 years) from the Baltimore Longitudinal Study of Aging wore the ActiGraph GT9X Link and the Actiwatch 2 simultaneously on the non-dominant wrist for 7.0 +/- 1.6 nights. Total sleep time (TST), wake after sleep onset (WASO), sleep efficiency, number of wake bouts, mean wake bout length, and sleep fragmentation index (SFI) were extracted from ActiGraph using the Cole-Kripke algorithm and from Actiwatch using the software default algorithm. These parameters were compared using paired t-tests, Bland-Altman plots, and Deming regression models. Stratified analyses were performed by age, sex, and body mass index (BMI). Compared to the Actiwatch, the ActiGraph estimated comparable TST and sleep efficiency, but fewer wake bouts, longer WASO, longer wake bout length, and higher SFI (all p < .001). Both devices estimated similar 1-min and 1% differences between participants for TST and SFI (beta = 0.99, 95% CI: 0.95, 1.03, and 0.91, 1.13, respectively), but not for other parameters. These differences varied by age, sex, and/or BMI. The ActiGraph and the Actiwatch provide comparable absolute and relative estimates of TST, but not other parameters. The discrepancies could result from device differences in movement collection and/or sleep scoring algorithms. Further comparison and calibration is required before these devices can be used interchangeably.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Calibration of wrist-worn ActiWatch 2 and ActiGraph wGT3X for assessment of physical activity in young adults
    Lee, Paul
    Tse, C. Y.
    GAIT & POSTURE, 2019, 68 : 141 - 149
  • [2] Comparison of Sedentary Estimates between activPAL and Hip- and Wrist-Worn ActiGraph
    Koster, Annemarie
    Shiroma, Eric J.
    Caserotti, Paolo
    Matthews, Charles E.
    Chen, Kong Y.
    Glynn, Nancy W.
    Harris, Tamara B.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2016, 48 (08) : 1514 - 1522
  • [3] Calibration and cross-validation of a wrist-worn Actigraph in young preschoolers
    Johansson, E.
    Ekelund, U.
    Nero, H.
    Marcus, C.
    Hagstromer, M.
    PEDIATRIC OBESITY, 2015, 10 (01): : 1 - 6
  • [4] Comparison of wrist-worn Fitbit Flex and waist-worn ActiGraph for measuring steps in free-living adults
    Chu, Anne H. Y.
    Ng, Sheryl H. X.
    Paknezhad, Mahsa
    Gauterin, Alvaro
    Koh, David
    Brown, Michael S.
    Muller-Riemenschneider, Falk
    PLOS ONE, 2017, 12 (02):
  • [5] A COMPARISON OF HIP-WORN AND WRIST-WORN ACTIGRAPH DATA IN LOW-ACTIVE OLDER ADULTS WITH OBESITY.
    Robison, Justin
    Miller, Michael E.
    Chen, Shyh-huei
    Rejeski, W. Jack
    Furlipa, Joy
    Fanning, Jason
    ANNALS OF BEHAVIORAL MEDICINE, 2022, 56 (SUPP 1) : S97 - S97
  • [6] Optical wrist-worn device for sleep monitoring
    Renevey, Ph.
    Delgado-Gonzalo, R.
    Lemkaddem, A.
    Proenca, M.
    Lemay, M.
    Sola, J.
    Tarniceriu, A.
    Bertschi, M.
    EMBEC & NBC 2017, 2018, 65 : 615 - 618
  • [7] Is Wrist Accelerometry Suitable for Threshold Scoring? A Comparison of Hip-Worn and Wrist-Worn ActiGraph Data in Low-Active Older Adults With Obesity
    Fanning, Jason
    Miller, Michael E.
    Chen, Shyh-Huei
    Davids, Carlo
    Kershner, Kyle
    Rejeski, W. Jack
    JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2022, 77 (12): : 2429 - 2434
  • [8] Development of digital measures for nighttime scratch and sleep using wrist-worn wearable devices
    Mahadevan, Nikhil
    Christakis, Yiorgos
    Di, Junrui
    Bruno, Jonathan
    Zhang, Yao
    Dorsey, E. Ray
    Pigeon, Wilfred R.
    Beck, Lisa A.
    Thomas, Kevin
    Liu, Yaqi
    Wicker, Madisen
    Brooks, Chris
    Kabiri, Nina Shaafi
    Bhangu, Jaspreet
    Northcott, Carrie
    Patel, Shyamal
    NPJ DIGITAL MEDICINE, 2021, 4 (01)
  • [9] Comparison Between Wrist-Worn and Waist-Worn Accelerometry
    Loprinzi, Paul D.
    Smith, Brandee
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2017, 14 (07): : 539 - 545
  • [10] Development of digital measures for nighttime scratch and sleep using wrist-worn wearable devices
    Nikhil Mahadevan
    Yiorgos Christakis
    Junrui Di
    Jonathan Bruno
    Yao Zhang
    E. Ray Dorsey
    Wilfred R. Pigeon
    Lisa A. Beck
    Kevin Thomas
    Yaqi Liu
    Madisen Wicker
    Chris Brooks
    Nina Shaafi Kabiri
    Jaspreet Bhangu
    Carrie Northcott
    Shyamal Patel
    npj Digital Medicine, 4