Modal parameter calculation and vibration characteristic analysis of transmission line conductor

被引:1
|
作者
Huang, Xinbo [1 ]
Lu, Xudong [1 ]
Zhao, Long [1 ]
Feng, Guoze [1 ]
机构
[1] Xian Polytech Univ, Sch Elect & Informat, Xian 710048, Peoples R China
关键词
broken strands; modal identification; structural health monitoring; transmission line conductor; vibration characteristic; IDENTIFICATION; FREQUENCY; TECHNOLOGY; CABLES; DAMAGE;
D O I
10.1049/gtd2.12830
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Structural damage identification technology based on modal parameters is an extremely effective monitoring method. Because of the structural characteristics of the conductor, with its small diameter and long span, it is not easy to obtain the modal parameters by manual excitation. Here, a method for structural health monitoring of the conductor under wind load excitation is proposed. Firstly, the natural frequency change law of the conductor after broken strand damage is obtained by analyzing the conductor modal parameters calculation formula and IEEE standards. Then, the vibration characteristics are calculated by vibration experiments and finite element methods. Finally, through the broken strand experiment, this paper demonstrates how to determine the damage degree of the conductor using the modal parameters. And it is applied to online monitoring in the field. The results show that this method is convenient, fast, and accurate.
引用
收藏
页码:2483 / 2496
页数:14
相关论文
共 50 条
  • [1] CALCULATION OF CHARACTERISTIC IMPEDANCE OF CONDUCTIVE TRANSMISSION LINE WITH RECTANGULAR OUTER CONDUCTOR AND TANGENTIAL POLYWIRE INNER CONDUCTOR
    庞小峰
    王慧
    [J]. Science Bulletin, 1988, (09) : 715 - 721
  • [2] CALCULATION OF CHARACTERISTIC IMPEDANCE OF CONDUCTIVE TRANSMISSION-LINE WITH RECTANGULAR OUTER CONDUCTOR AND TANGENTIAL-POLYWIRE INNER CONDUCTOR
    PANG, XF
    WANG, H
    [J]. KEXUE TONGBAO, 1988, 33 (09): : 715 - 721
  • [3] Simplified Vibration Model and analysis of a single-conductor transmission line with dampers
    Barry, O.
    Long, R.
    Oguamanam, D. C. D.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2017, 231 (22) : 4150 - 4162
  • [4] Calculation of Field Strength of Bundle Conductor Surface of Transmission Lines and Analysis of It along the Transmission Line
    Wang, Huayun
    Li, Qiong
    Xie, Gonghao
    He, Wangling
    Lan, Lei
    [J]. 2019 IEEE 3RD INTERNATIONAL CONFERENCE ON GREEN ENERGY AND APPLICATIONS (ICGEA 2019), 2019, : 16 - 20
  • [6] VIBRATION BEHAVIOR OF OVERHEAD TRANSMISSION-LINE COMPONENTS IN THE PRESENCE OF CONDUCTOR VIBRATION
    GIESE, K
    [J]. ENERGIETECHNIK, 1978, 28 (11): : 433 - 437
  • [7] Analysis on Data Characteristic and Mechanism of Wind Vibration Disaster of Power Transmission Line
    Li Peng
    Liu Bin
    Li Tong
    Liu He
    Cheng Yongfeng
    Li Danyu
    Wang Jingchao
    Yang Jialun
    Fei Xiangze
    Ji Kunpeng
    Zhao Bin
    [J]. 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING, 2019, 358
  • [8] Parameter analysis of wind-induced vibration of electrical transmission line models
    You Yi
    Zhao Shuang
    Wensheng, Li
    He Cheng
    [J]. PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON CIVIL, TRANSPORTATION AND ENVIRONMENTAL ENGINEERING (ICCTE 2017), 2017, 135 : 129 - 134
  • [9] Characteristic impedance of a TEM transmission line with non standard inner conductor
    Szczypka, Z
    [J]. MIKON-2000, VOLS 1 & 2, PROCEEDINGS, 2000, : 56 - 60
  • [10] Modal Analysis of Transmission Line Cables
    Barbieri, Nilson
    Mannala, Marcos Jose
    Barbieri, Renato
    Tenorio Calado, Mayara Kelly
    Vitor Barbieri, Gabriel de Sant'Anna
    [J]. DYNAMICS OF COUPLED STRUCTURES, VOL 4, 2017, : 367 - 370