Particle size distribution in the evaluation of the inhalation toxicity of cosmetic spray products

被引:1
|
作者
Berrada-Gomez, Marie-Pierre [1 ]
Bui, Beatrice
Bondarenko, Hanna [1 ]
Ferret, Pierre-Jacques [1 ]
机构
[1] Pierre Fabre Dermo Cosmet, Safety Assessment Dept, 3 Ave Hubert Curien, F-31035 Toulouse, France
关键词
Aerosol; Cosmetics; Inhalation exposure; Particle size; Spray;
D O I
10.1016/j.yrtph.2023.105359
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
While applying cosmetic sprays (pump sprays and propellant-based sprays) intended for use on the skin or hair, consumers may unintentionally inhale sprayed droplets/particles. Thus, it is essential to analyze the size dis-tribution of sprayed droplets/particles because those less than 10 mu m are considered to be respirable and may present a high systemic and local exposure risk. In this study, we investigated the droplet/particle size distri-bution of 78 cosmetic sprays by laser diffraction. Our results showed that the level of respirable droplets/par-ticles released by pump sprays averaged 0.5% of all particles measured (0.00%-2.23%) and that released by propellant-based sprays averaged 15.25% (0.15%-32.27%). Dry shampoos (powder) released the highest per-centage of respirable droplets/particles (16.66%-32.27%). A default value of 25% of respirable droplets/parti-cles can also be suggested for dry shampoos. Droplet/particle size distribution was influenced by the spray dispensing system (pump or propellant-based), the product type (hairspray, sunscreen, etc.) and the galenic form (powder, oil, emulsion, etc.). However, it should be noted that more confidence is placed in the pump spray data due to the larger sample size. This study provides data on droplet/particle size, which may be used in a modelling approach to predict inhalation exposure. Therefore, it must be known and used, together with assessments of intrinsic and local toxicities to determine the margin of safety of the product by inhalation route, and to assess the risk of cosmetic sprays.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Consistency Evaluation of Particle Size Distribution of Nasal Spray
    Zhao, Rongjun
    Chen, Hongye
    Chen, Zhuxia
    Su, Chaofen
    Liang, Chaofeng
    Chinese Journal of Pharmaceuticals, 2022, 53 (04) : 539 - 542
  • [2] Inhalation toxicity assessment of powder cosmetic products with an in vitro pulmonary model
    Bui, B.
    Berrada-Gomez, M. -P.
    Ferret, P. -J.
    TOXICOLOGY LETTERS, 2023, 384 : S168 - S168
  • [3] An In Vitro Method for Predicting Inhalation Toxicity of Impregnation Spray Products
    Sorli, Jorid B.
    Hansen, Jitka S.
    Norgaard, Asger W.
    Levin, Marcus
    Larsen, Soren T.
    ALTEX-ALTERNATIVES TO ANIMAL EXPERIMENTATION, 2015, 32 (02) : 101 - 111
  • [4] In vitro evaluation of the inhalation toxicity of the cosmetic ingredient aluminum chlorohydrate
    Tha, Emanoela Lundgren
    Gagosian, Viviana Stephanie Costa
    Canavez, Andrezza Di Pietro Micali
    Schuck, Desiree Cigaran
    Brohem, Carla Abdo
    Gradia, Daniela Fiori
    de Freitas, Rilton Alves
    Prado, Karin Braun
    Cestari, Marta Margarete
    Lorencini, Marcio
    Leme, Daniela Morais
    JOURNAL OF APPLIED TOXICOLOGY, 2022, 42 (12) : 2016 - 2029
  • [5] EFFECT OF PARTICLE-SIZE ON INHALATION TOXICITY OF CHLORFENVINPHOS
    TSUDA, S
    IWASAKI, M
    YOSHIDA, M
    IKEDA, T
    SHIRASU, Y
    JAPANESE JOURNAL OF VETERINARY SCIENCE, 1986, 48 (04): : 729 - 737
  • [6] Toxicity of waterproofing spray is influenced by the mist particle size
    Yamashita, M
    Yamashita, M
    Tanaka, J
    Hirai, H
    Suzuki, M
    Kajigaya, H
    VETERINARY AND HUMAN TOXICOLOGY, 1997, 39 (06) : 332 - 334
  • [7] EFFECT OF PARTICLE-SIZE ON INHALATION TOXICITY OF NALED AEROSOLS
    BERTEAU, PE
    DEEN, WA
    DIMMICK, RL
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 1977, 41 (01) : 183 - 183
  • [8] Effect of Spray Particle Size Distribution on Deposition in Human Respiratory Tract - Safety Evaluation
    Goel, Anubha
    Bhandari, Pinki
    Izhar, Saifi
    Sharma, Chhavi
    Patanjali, P. K.
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2020, 79 (07): : 653 - 655
  • [9] PARTICLE-SIZE DISTRIBUTION IN SPRAY-DRYING
    IVANOV, EV
    MOSHINSKII, AI
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 1994, 67 (12) : 1742 - 1745
  • [10] Particle Size Distribution Analysis of OTC Aerosol or Powder Drug Products With Potential for Inadvertent Inhalation Exposure to Consumers
    Liu, Xiaofei
    Rua, Diego
    Wokovich, Anna
    Guo, Changning
    Keire, David