Femtosecond Laser Fabrication and Refractive Index Sensing Characteristics of Highly Sensitive Fiber Michelson Microcavity

被引:3
|
作者
Li, Xiaowei [1 ]
Bai, Rubing [1 ]
Du, Lingyu [1 ]
Zhang, Wanli [2 ]
Li, Min [1 ]
机构
[1] Chifeng Univ, Sch Phys & Intelligent Mfg Engn, Chifeng 024000, Peoples R China
[2] Harbin Inst Technol Weihai, Dept Optoelect Sci, Weihai 264209, Peoples R China
关键词
Femtosecond laser; Michelson interferometer (MI); microcavity; optical fiber refractive index (RI) sensing; temperature crosstalk compensation; FABRY-PEROT-INTERFEROMETER; MACH-ZEHNDER INTERFEROMETERS; SENSOR; TEMPERATURE;
D O I
10.1109/JSEN.2023.3333550
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, a compact optical fiber refractive index (RI) sensing probe based on Michelson interference and Fabry-P & eacute;rot interference is proposed through fabricating a microcavity in the multimode optical fiber (MMF) by using the femtosecond laser-induced water breakdown technique. This probe not only exhibits ultrahigh RI sensitivity but also possesses high accuracy of RI measurement by compensating temperature crosstalk. The RI and temperature sensing characteristics of this probe are investigated theoretically and experimentally. The theoretical RI sensitivity of the fiber probe is up to -10000 nm/RIU, and the theoretical temperature sensitivity is 33 pm/degrees C. In the experiment, the RI sensitivity of Michelson interference peak is -11523.8 nm/RIU in the range of 1.333-1.3387, and temperature sensitivity is 49.43 pm/degrees C in the range of 18.75 degrees C-55.38 degrees C in the air. Theoretical and experimental results agree well. At the same time, the RI and the temperature sensitivities of Fabry-P & eacute;rot interference peak are measured. The RI sensitivity of Fabry-P & eacute;rot interference peak is 422.75 nm/RIU, and temperature sensitivity is 8.06 pm/degrees C. The accuracy of RI measurement can be further improved by using the method of sensing matrix. The proposed RI sensing probe exhibited small volume, ultrahigh sensitivity, and high accuracy. It will be adapted to the RI detection in many fields and exhibits a widely practical application prospect.
引用
收藏
页码:1432 / 1442
页数:11
相关论文
共 50 条
  • [1] Highly Sensitive Refractive Index Optical Fiber Sensors Fabricated by a Femtosecond Laser
    Yang, Jinpeng
    Jiang, Lan
    Wang, Sumei
    Chen, Qianghua
    Li, Benye
    Xiao, Hai
    IEEE PHOTONICS JOURNAL, 2011, 3 (06): : 1189 - 1197
  • [2] Femtosecond laser fabrication of long period fiber gratings and applications in refractive index sensing
    Li, Benye
    Jiang, Lan
    Wang, Sumei
    Tsai, Hai-Lung
    Xiao, Hai
    OPTICS AND LASER TECHNOLOGY, 2011, 43 (08): : 1420 - 1423
  • [3] Temperature and refractive index measurements by using a microcavity engraved with femtosecond laser in multimode fiber
    Fiorin, Rodrigo
    Adachi, Jociel L. da S.
    de Oliveira, Valmir
    Kalinowski, Hypolito J.
    Kamikawachi, Ricardo C.
    Abe, Ilda
    2017 25TH INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS (OFS), 2017, 10323
  • [4] Fiber In-line Michelson Interferometer for Refractive Index Sensing
    Liao, C. R.
    Wang, D. N.
    Wang, Min
    Yang, Minghong
    Wang, Yiping
    FOURTH ASIA PACIFIC OPTICAL SENSORS CONFERENCE, 2013, 8924
  • [5] Highly refractive index sensitive femtosecond laser inscribed long period gratings
    Davies, Edward
    Kalli, Kyriacos
    Koutsides, Charalambos
    Zhang, Lin
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
  • [6] Femtosecond laser fabricated fiber Bragg grating in microfiber for refractive index sensing
    Fang, X.
    Liao, C. R.
    Wang, D. N.
    OPTICS LETTERS, 2010, 35 (07) : 1007 - 1009
  • [7] Fiber inline Michelson interferometer fabricated by CO2 laser irradiation for refractive index sensing
    Wu, Hongbin
    Yuan, Lei
    Zhao, Longjiang
    Cao, Zhitao
    Wang, Peng
    ADVANCED FABRICATION TECHNOLOGIES FOR MICRO/NANO OPTICS AND PHOTONICS VII, 2014, 8974
  • [8] Highly sensitive refractive index fiber inline Mach-Zehnder interferometer fabricated by femtosecond laser micromachining and chemical etching
    Sun, Xiao-Yan
    Chu, Dong-Kai
    Dong, Xin-Ran
    Chu-Zhou
    Li, Hai-Tao
    Luo-Zhi
    Hu, You-Wang
    Zhou, Jian-Ying
    Cong-Wang
    Duan, Ji-An
    OPTICS AND LASER TECHNOLOGY, 2016, 77 : 11 - 15
  • [9] Vernier-effect-based fiber microcoupler for highly sensitive liquid refractive index sensing
    Sun, Hanchao
    Wu, Jixuan
    Song, Binbin
    Liu, Haifeng
    Duan, Shaoxiang
    Liu, Xiao
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (05)
  • [10] Asymmetrical Twin-Core Fiber Based Michelson Interferometer for Refractive Index Sensing
    Zhou, Ai
    Li, Guangping
    Zhang, Yanhui
    Wang, Yuzhuo
    Guan, Chunying
    Yang, Jun
    Yuan, Libo
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2011, 29 (19) : 2985 - 2991