Portable biosensor for the detection of Enrofloxacin and Ciprofloxacin antibiotic residues in food, body fluids, environmental and wastewater samples

被引:31
|
作者
Mathai, Tennyson [1 ]
Pal, Tathagata [1 ]
Prakash, Nayan [1 ]
Mukherji, Soumyo [1 ]
机构
[1] Indian Inst Technol Mumbai, Dept Biosci & Bioengn, Mumbai, India
来源
关键词
Antibiotic biosensors; Evanescent wave; Fiber optic biosensor; Fluoroquinolone; Portable biosensor; Wastewater; PERFORMANCE LIQUID-CHROMATOGRAPHY; AQUATIC ENVIRONMENT; THERMAL-STABILITY; MASS-SPECTROMETRY; OPTICAL-FIBER; SURFACE; FLUOROQUINOLONES; PHARMACEUTICALS; IDENTIFICATION; CONTAMINATION;
D O I
10.1016/j.bios.2023.115478
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Enrofloxacin (ENR) and its metabolite Ciprofloxacin (CIP) are both a class of fluoroquinolone antibiotics effective against a broad-spectrum microbial infection. Recent surge in the consumption of CIP and ENR has been linked to increased cases of drug-resistant pathogens. This is due to the fact that the antibiotic residues remain in milk, meat, soil and environmental water for a prolonged duration. Although gold standard methods such as LC-MS are sensitive, they suffer from expensive operation and maintenance cost, and would need dedicated facilities and tedious sample preparation steps. Such limitations make on site detection impossible for regulatory bodies in developing countries. To address this issue, we developed a portable device that can detect the presence of CIP and ENR antibiotics in the range of parts per billion (ppb) concentrations accurately. It consists of a polyaniline (PAni) coated U-bent optical fiber with anti-ENR/CIP antibody immobilized on the polymer surface. The sensor relies on the principle of evanescent wave absorbance by antigen-antibody complex. The sensor showed limit of detection (LOD) of 1 ppb with a linear range of operation from 1 ppb to 500 ppb (R2 = 0.96-0.99) in lake water, waste water treatment plant effluent, urine, blood serum, milk and meat samples. The recovery of the sensor ranges from 88% to 120% indicating reasonable accuracy. The sensor has excellent selectivity towards CIP and ENR and showed stability for four weeks indicating its field deployability and robustness. The portable sensor is scalable and contract has been given to an industry partner to mass manufacture the device.
引用
收藏
页数:9
相关论文
共 13 条
  • [1] A portable EIS-based biosensor for the detection of microcystin-LR residues in environmental water bodies and simulated body fluids
    Mandal, Atindra Kanti
    Pal, Tathagata
    Kumar, Satish
    Mukherji, Suparna
    Mukherji, Soumyo
    ANALYST, 2024, 149 (07) : 2170 - 2179
  • [2] Aptamer biosensor for antibiotic residues detection in food analysis
    Yemin, Guo
    Xiangyou, Wang
    Xia, Sun
    Sensors and Transducers, 2013, 156 (09): : 368 - 373
  • [3] Research progress on portable electrochemical sensors for detection of mycotoxins in food and environmental samples
    Jiang, Youwei
    Sima, Yingyu
    Liu, Lei
    Zhou, Chuanqin
    Shi, Shuting
    Wan, Kun
    Chen, Aiting
    Tang, Nana
    He, Quanguo
    Liu, Jun
    CHEMICAL ENGINEERING JOURNAL, 2024, 485
  • [4] A smartphone-based supramolecular biosensor for portable and rapid detection of buprofezin in real food samples
    Zhan, Yilin
    Li, Na
    Qin, Tianyi
    Peng, Linhui
    Deng, Weihua
    Xu, Zhongyong
    Wang, Lei
    Charles, Immanuel David
    Liu, Bin
    FOOD CHEMISTRY, 2024, 460
  • [5] Emerging optical and electrochemical biosensing approaches for detection of ciprofloxacin residues in food and environment samples: A comprehensive overview
    Ansari, Mohammad Javed
    Bokov, Dmitry Olegovich
    Jasim, Saade Abdalkareem
    Rudiansyah, Mohammad
    Suksatan, Wanich
    Yasin, Ghulam
    Chupradit, Supat
    Alkaim, Ayad F.
    Mustafa, Yasser Fakri
    Tarek, Dhuha Imad
    JOURNAL OF MOLECULAR LIQUIDS, 2022, 354
  • [6] Thylakoid-based green preparation of porous microneedles for antibiotic residues detection in food samples
    Huang, Rongrong
    Xu, Yue
    Wan, Peipei
    Zhu, Tong
    Heng, Weili
    Miao, Wenjun
    ANALYTICA CHIMICA ACTA, 2024, 1328
  • [7] A Universal LC-MS/MS Method for Simultaneous Detection of Antibiotic Residues in Animal and Environmental Samples
    Chan, Chak-Lun
    Wai, Hogan Kok-Fung
    Wu, Peng
    Lai, Siu-Wai
    Chan, Olivia Sinn-Kay
    Tun, Hein M.
    ANTIBIOTICS-BASEL, 2022, 11 (07):
  • [8] MNAzyme catalyzed signal amplification-mediated lateral flow biosensor for portable and sensitive detection of mycotoxin in food samples
    Yang, Yan
    Shi, Yiheng
    Zhang, Xianlong
    Li, Guoliang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (04) : 913 - 923
  • [9] MNAzyme catalyzed signal amplification-mediated lateral flow biosensor for portable and sensitive detection of mycotoxin in food samples
    Yan Yang
    Yiheng Shi
    Xianlong Zhang
    Guoliang Li
    Analytical and Bioanalytical Chemistry, 2024, 416 : 1057 - 1067
  • [10] Perspective and application of molecular imprinting approach for antibiotic detection in food and environmental samples: A critical review
    Tarannum, Nazia
    Khatoon, Shahjadi
    Dzantiev, Boris B.
    FOOD CONTROL, 2020, 118