Capabilities of simultaneous 193 nm - LIBS/LA-ICP-MS imaging for microplastics characterization

被引:5
|
作者
Brunnbauer, Lukas [1 ]
Jirku, Mara [1 ]
Quarles Jr, C. Derrick [2 ]
Limbeck, Andreas [1 ]
机构
[1] Inst Chem Technol & Analyt, TU Wien, Getreidemarkt 9-164-I2AC, A-1060 Vienna, Austria
[2] Elemental Sci Inc, Omaha, NE USA
基金
奥地利科学基金会;
关键词
MASS-SPECTROMETRY; IDENTIFICATION; SPECTROSCOPY;
D O I
10.1016/j.talanta.2023.125500
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microplastics (MPs) are currently one of the major environmental challenges within our society. With the awareness of the impact of MPs on the environment increasing over the last years, the need for increased monitoring as well as comprehensive analysis to better understand the fate and impact of MPs has become more and more important. A major aspect of MP characterization is the assignment of the polymer type of individual particles. Here, per-and poly-fluoroalkyl substances (PFAS), originating from fluor-containing polymers, have gained a lot of attention due to the severe environmental impact. Additionally, quantitative analysis of the metal content is of great interest in the field, since MPs are prone to either leaching (in)organic additives into the environment or taking up and accumulating hazardous components (e.g., heavy metals). In this work we demonstrate the capabilities of a simultaneous LIBS/LA-ICP-MS setup for the analysis of MPs. In the first part, we demonstrate the potential of targeted LIBS analysis for the imaging of fluor-containing polymers. Using a laser spot size of 5 mu m combined with highly sensitive ICCD detection enables analysis of particles in the low mu m range. In the second part we combine the polymer-identification capabilities of LIBS with the high sensitivity of ICP-MS to perform matrix-matched quantification of the metal content of individual MPs. In this case we use a spot size of 50 mu m facilitating polymer classification with a broadband spectrometer, resulting in detection limits of 0.72 mu g/g for Pb and 9.5 mu g/g for Sn simultaneously measured using ICP-MS.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Simultaneous 3-dimensional elemental imaging with LIBS and LA-ICP-MS
    Chirinos, Jose R.
    Oropeza, Dayana D.
    Gonzalez, Jhanis J.
    Hou, Huaming
    Morey, Mark
    Zorba, Vassilia
    Russo, Richard E.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (07) : 1292 - 1298
  • [2] Simultaneous LIBS and LA-ICP-MS analysis of industrial samples
    Latkoczy, Christopher
    Ghislain, Thierry
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) : 1152 - 1160
  • [3] Development of a simultaneous LA-ICP-MS & LIBS method for the investigation of polymer degradation
    Willner, Jakob
    Brunnbauer, Lukas
    Quarles, C. Derrick, Jr.
    Nelhiebel, Michael
    Larisegger, Silvia
    Limbeck, Andreas
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (10) : 2028 - 2037
  • [4] Elemental analysis of packaging tapes by LA-ICP-MS and LIBS
    Martinez-Lopez, Claudia
    Sakayanagi, Masataka
    Almirall, Jose R.
    FORENSIC CHEMISTRY, 2018, 8 : 40 - 48
  • [5] Application of LIBS and LA-ICP-MS analysis to Hellenistic tableware
    Charlton, Michael
    Mise, Maja
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (10):
  • [6] Capabilities of a homogenized 266 nm Nd:YAG laser ablation system for LA-ICP-MS
    Guillong, M
    Horn, I
    Günther, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (01) : 8 - 14
  • [7] Capabilities of a homogenized 266 nm Nd:YAG laser ablation system for LA-ICP-MS
    Günther, D., 1600, Royal Society of Chemistry (17):
  • [8] Solid sample analysis by a Tandem LIBS and LA-ICP-MS system
    Gonzalez, Jhanis
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [9] Elemental and molecular imaging by LA-ICP-MS
    Fernandez, Beatriz
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (03) : 547 - 548
  • [10] Elemental and molecular imaging by LA-ICP-MS
    Beatriz Fernández
    Analytical and Bioanalytical Chemistry, 2019, 411 : 547 - 548