Contrast-Enhanced Ultrasonography for Transabdominal and Transrectal Ultrasound in Staging Cervical Cancer: A Reliability Study

被引:2
|
作者
Zhang, Juan [1 ]
Xiang, Jiang-Dong [1 ]
Jia, Chao [2 ]
Du, Lian-Fang [2 ]
Li, Fan [2 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Sch Med, Dept Gynaecol & Obstet, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Sch Med, Dept Ultrasound, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Sch Med, Dept Ultrasound, 650 Xin Song Jiang Rd, Shanghai 201620, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2023年 / 49卷 / 10期
关键词
Contrast media; Ultrasonography; Cervical cancer; Cancer staging; Value; Transabdominal; Transrectal; ANGIOGENESIS;
D O I
10.1016/j.ultrasmedbio.2023.06.018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: This retrospective study aimed to evaluate the consistency of transrectal contrast-enhanced ultrasonography (TR-CEUS) with post-operative pathology and the value of contrast-enhanced ultrasonography (CEUS) in staging surgically treated cervical cancer when combined with conventional ultrasonography (US). Methods: From October 2020 to March 2023, hospitalized patients with stage IB and II cervical cancer confirmed by total hysterectomy were consecutively enrolled. The standard images of US and CEUS by transabdominal (TAUS/CEUS) and transrectal (TR-US/CEUS) approaches and magnetic resonance imaging (MRI) were acquired, on which the size and stage of the tumors were evaluated, and the consistency of results with the pathological specimen was analyzed. Results: Thirty-nine patients with cervical cancer were finally enrolled in this study. The results showed that CEUS significantly improved the reliability of TA-US in evaluating tumor diameter; the intraclass correlation coefficient (ICC) was from 0.672 to 0.735. TR-US indicated good reliability with or without the addition of CEUS (ICC = 0.796 and 0.780). In terms of tumor staging, CEUS improved the consistency of transabdominal (weighted ? values from 0.689 to 0.731) and transrectal staging of tumors (? from 0.758 to 0.785), and the staging of TR-US combined with TR-CEUS had the highest consistency with post-operative results, similar to MRI (?, respectively 0.785 and 0.789). CEUS can reflect the heterogeneity of the tumor. Heterogeneous enhancement and perfusion defects were more common in >2 cm cervical cancer (50%, 20/40 and 52.5%, 21/40), respectively, and perfusion defects were more common in moderately to poorly differentiated tumors (66.67%, 20/30). Conclusion: For stage IB and IIA cervical cancer, CEUS can aid in assessing the International Federation for Gynecology and Obstetrics staging of tumors alongside TA-US and TR-US. The combination of TR-US and TR-CEUS has shown good consistency with pathology in the staging of cervical cancer, comparable to that of MRI.
引用
收藏
页码:2283 / 2290
页数:8
相关论文
共 50 条
  • [1] Transabdominal Contrast-Enhanced Ultrasonography of Pancreatic Cancer
    Kersting, Stephan
    Roth, Johanna
    Bunk, Alfred
    PANCREATOLOGY, 2011, 11 : 20 - 27
  • [2] Biplane transrectal ultrasonography plus ultrasonic elastosonography and contrast-enhanced ultrasonography in T staging of rectal cancer
    Yanru Feng
    Chanjuan Peng
    Yuan Zhu
    Luying Liu
    BMC Cancer, 20
  • [3] Biplane transrectal ultrasonography plus ultrasonic elastosonography and contrast-enhanced ultrasonography in T staging of rectal cancer
    Feng, Yanru
    Peng, Chanjuan
    Zhu, Yuan
    Liu, Luying
    BMC CANCER, 2020, 20 (01)
  • [4] Contrast-enhanced transrectal ultrasonography for the detection of diffuse prostate cancer
    Gao, Y.
    Liao, X. H.
    Lu, L.
    Wang, L.
    Ma, Y.
    Qin, H. Z.
    Yan, X.
    Guo, P.
    CLINICAL RADIOLOGY, 2016, 71 (03) : 258 - 264
  • [5] The value and limitations of contrast-enhanced transrectal ultrasonography for the detection of prostate cancer
    Zhao, Han-Xue
    Xia, Chun-Xia
    Yin, Hong-Xia
    Guo, Ning
    Zhu, Qiang
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E641 - E647
  • [6] Contrast-enhanced transrectal ultrasonography of a novel canine prostate cancer model
    Forsberg, F
    Johnson, DK
    Merton, DA
    Liu, JB
    Losco, PE
    Hagen, EK
    Goldberg, BB
    JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (09) : 1003 - 1013
  • [7] Contrast-Enhanced Transrectal Ultrasound in Focal Therapy for Prostate Cancer
    Ashrafi, Akbar N.
    Nassiri, Nima
    Gill, Inderbir S.
    Gulati, Mittul
    Park, Daniel
    de Castro Abreu, Andre L.
    CURRENT UROLOGY REPORTS, 2018, 19 (10)
  • [8] Contrast-Enhanced Transrectal Ultrasound in Focal Therapy for Prostate Cancer
    Akbar N. Ashrafi
    Nima Nassiri
    Inderbir S. Gill
    Mittul Gulati
    Daniel Park
    Andre L. de Castro Abreu
    Current Urology Reports, 2018, 19
  • [9] TRANSABDOMINAL CONTRAST-ENHANCED ULTRASOUND IMAGING OF THE PROSTATE
    Mischi, Massimo
    Demi, Libertario
    Smeenge, Martijn
    Kuenen, Maarten P. J.
    Postema, Arnoud W.
    de la Rosette, Jean J. M. C. H.
    Wijkstra, Hessel
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (04): : 1112 - 1118
  • [10] PROSPECTIVE COMPARISON OF ORAL CONTRAST-ENHANCED TRANSABDOMINAL ULTRASOUND IMAGING WITH CONTRAST-ENHANCED COMPUTED TOMOGRAPHY IN PRE-OPERATIVE TUMOR STAGING OF GASTRIC CANCER
    Wu, Ling-Ling
    Xin, Jun-Yi
    Wang, Jing-Jing
    Feng, Qun-Qun
    Xu, Xiao-Li
    Li, Kai-Yan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (02): : 569 - 577