Improving CO2 concentration, CO2 pollutant and occupants' thermal comfort in a residential building using genetic algorithm optimization

被引:12
|
作者
Baghoolizadeh, Mohammadreza [1 ]
Rostamzadeh-Renani, Mohammad [2 ]
Hakimazari, Mohammad [3 ]
Rostamzadeh-Renani, Reza [2 ]
机构
[1] Shahrekord Univ, Dept Mech Engn, Shahrekord 8818634141, Iran
[2] Politecn Milan, Energy Dept, Via Lambruschini 4, I-20156 Milan, Italy
[3] Univ Art, Fac Architecture & Urbanism, Dept Architecture, Tehran, Iran
关键词
NSGA-II algorithm; Thermal comfort; Software; Indoor air quality (IAQ); CO; 2; pollutant; INDOOR AIR-QUALITY; CARBON-DIOXIDE CONCENTRATION; MULTIOBJECTIVE OPTIMIZATION; ENERGY-CONSUMPTION; ENVIRONMENTAL-QUALITY; SENSITIVITY-ANALYSIS; NSGA-II; SIMULATION; HEAT; PERFORMANCE;
D O I
10.1016/j.enbuild.2023.113109
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Environmental air pollutants pose a serious threat to human society's health and way of life, and their amount is rising quickly. Given that we spend the majority of our time indoors, good indoor air quality (IAQ) is essential. When the concentration of pollutants that have seeped into the building space, like CO2, is reduced, this favorable air quality becomes significant. 39 design factors, including the temperature setting of the air condi-tioning system's (Acs) thermostat for cooling and heating, the insulation level of the residents' clothing and the air speed for all months of the year, the level of activity envelope building, and the amount of clean air that is transferred from the outside to the inside of the building by the air conditioning, have been taken into account in this research in order to solve this significant problem in the residential sector. The objective is to simultaneously lower CO2 concentration (CCO2) and CO2 pollutant (PCO2) and raise thermal comfort (Tc) levels for building occupants. Design variables and objective functions are defined in JEPLUS software. Using EnergyPlus software, they are subsequently examined in terms of the building's energy efficiency. The extracted data is then sent to the JEPLUS EA software. In this software, Morris sensitivity analysis (MSA) is used to determine how input variables affect particular objective functions, and the NSGA-II algorithm is then used to optimize the results, which allows users to select any mode that best suits their objectives. According to the optimization's findings in terms of CCO2, PCO2 and the residents' Tc were improved by 17-30, 15-37, and 52-80 percent, respectively. The levels of additional pollutants (CH4, N2O, NOx, SO2) that decreased were also examined.
引用
收藏
页数:25
相关论文
共 50 条
  • [1] Experimental and CFD modelling for thermal comfort and CO2 concentration in office building
    Kabrein, H.
    Hariri, A.
    Leman, A. M.
    Yusof, M. Z. M.
    Afandi, A.
    [J]. 2ND INTERNATIONAL CONFERENCE ON COMPUTATIONAL FLUID DYNAMICS IN RESEARCH AND INDUSTRY (CFDRI 2017), 2017, 243
  • [2] Genetic algorithm optimization of sensor placement for CO2 concentration observation
    Matsuda, Tomoaki
    Narieda, Shusuke
    [J]. IEICE COMMUNICATIONS EXPRESS, 2024, 13 (09): : 393 - 396
  • [3] A study on changes in occupants' thermal sensation owing to CO2 concentration using PMV and TSV
    Shin, Hakjong
    Kang, Minho
    Mun, Sun-Hye
    Kwak, Younghoon
    Huh, Jung-Ho
    [J]. BUILDING AND ENVIRONMENT, 2021, 187
  • [4] The effects of warmth and CO2 concentration, with and without bioeffluents, on the emission of CO2 by occupants and physiological responses
    Kuga, Kazuki
    Ito, Kazuhide
    Wargocki, Pawel
    [J]. INDOOR AIR, 2021, 31 (06) : 2176 - 2187
  • [5] Co2 as pollutant [2]
    Mosher, S.
    [J]. Coal Age, 2001, 106 (06):
  • [6] HVAC system optimization with CO2 concentration control using genetic algorithms
    Congradac, Velimir
    Kulic, Filip
    [J]. ENERGY AND BUILDINGS, 2009, 41 (05) : 571 - 577
  • [7] EFFECT OF CONTROL OPTIMIZATION OF CO2 TRANSCRITICAL SPLIT AIR CONDITIONER ON THERMAL COMFORT OF OCCUPANTS IN SINGLE ZONE ROOM
    Kadam, Ashish
    Padalkar, Atul
    Martinez-Ballester, S.
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2014, 22 (01)
  • [8] Is CO2 Indoor Pollutant?
    Fisk, William J.
    Satish, Usha
    Mendell, Mark J.
    Hotchi, Toshifumi
    Sullivan, Douglas
    [J]. ASHRAE JOURNAL, 2013, 55 (03) : 84 - 85
  • [9] Is CO2 Indoor Pollutant?
    Dirkes, James V., II
    [J]. ASHRAE JOURNAL, 2013, 55 (05) : 14 - 14
  • [10] A prediction model for CO2 concentration and multi-objective optimization of CO2 concentration and annual electricity consumption cost in residential buildings using ANN and GA
    Baghoolizadeh, Mohammadreza
    Rostamzadeh-Renani, Mohammad
    Dehkordi, Seyed Amir Hossein Hashemi
    Rostamzadeh-Renani, Reza
    Toghraie, Davood
    [J]. JOURNAL OF CLEANER PRODUCTION, 2022, 379