Load identification of a 2.5 MW wind turbine tower using Kalman filtering techniques and BDS data

被引:4
|
作者
Wei, Da [1 ]
Li, Dongsheng [2 ,4 ]
Jiang, Tao [2 ]
Lyu, Pin [3 ]
Song, Xiaofei [3 ]
机构
[1] Dalian Univ Technol, Dept Civil Engn, Dalian, Peoples R China
[2] Shantou Univ, Guangdong Engn Ctr Struct Safety & Hlth Monitoring, MOE Key Lab Intelligent Mfg Technol, Shantou 515063, Guangdong, Peoples R China
[3] Xinjiang Goldwind Sci & Technol Co Ltd, 8 Boxing Rd, Beijing 100176, Peoples R China
[4] Shantou Univ, Guangdong Engn Ctr Struct Safety & Hlth Monitoring, Dept Civil & Environm Engn, Shantou 515063, Guangdong, Peoples R China
关键词
Wind turbine; Thrust and bending moment estimation; BDS; Health monitoring; Kalman filter; INPUT-STATE ESTIMATION; MINIMUM-VARIANCE INPUT; FORCE IDENTIFICATION; SYSTEMS;
D O I
10.1016/j.engstruct.2023.115763
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The rapid increase in the number of wind turbine installations and operations, is increasing the importance of the health monitoring of these wind turbines. To assess the remaining service life of a wind turbine, continuous monitoring of the internal forces acting on the critical locations of fatigue in the structure is required. However, a large number of sensors are usually required for the comprehensive determination of the internal force at a site -specific location; additionally, these sensors cannot be placed in locations with strong stress or strain gradients. Therefore, in this paper, a strategy for estimating the thrust at the tower top and the bending moment at any position of the wind turbine tower is proposed, which only requires a limited number of acceleration sensors and the BeiDou Navigation Satellite System (BDS). The estimated load includes static and dynamic components. The former is calculated by fitting the derived function and the BDS data, and the latter is estimated by the time -domain inverse method using the Kalman filter and with acceleration sensors. The performance of the pro-posed strategy is validated in two case studies, including simulated data and recorded data from a 2.5 MW onshore wind turbine located in China. The results show that the strategy can produce an estimation of thrust and bending moment, with good accuracy.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [1] Load Analysis of 2.5MW Offshore Wind Turbine Tower
    Ji, Caiyun
    Zhu, Longbiao
    Zhu, Zhisong
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE II, PTS 1-6, 2012, 121-126 : 206 - 212
  • [2] Continuous strain prediction for fatigue assessment of an offshore wind turbine using Kalman filtering techniques
    Maes, K.
    De Roeck, G.
    Lombaert, G.
    Iliopoulos, A.
    Van Hemelrijck, D.
    Devriendt, C.
    Guillaume, P.
    2015 IEEE WORKSHOP ON ENVIRONMENTAL, ENERGY AND STRUCTURAL MONITORING SYSTEMS (EESMS), 2015, : 44 - 49
  • [3] Research and verification of dynamic load identification for a large wind turbine tower
    Wu F.
    Yang C.
    Wang Q.
    Yang L.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2020, 39 (20): : 197 - 203
  • [4] Wind Turbine Tower Deformation Measurement Using Terrestrial Laser Scanning on a 3.4 MW Wind Turbine
    Helming, Paula
    von Freyberg, Axel
    Sorg, Michael
    Fischer, Andreas
    ENERGIES, 2021, 14 (11)
  • [5] Operational modal analysis of a 2.5MW wind turbine using optical measurement techniques and strain gauges
    Ozbek, Muammer
    Rixen, Daniel J.
    WIND ENERGY, 2013, 16 (03) : 367 - 381
  • [6] Periodic Load Estimation of a Wind Turbine Tower using a Model Demodulation Transformation
    Pamososuryo, Atindriyo Kusumo
    Mulders, Sebastiaan Paul
    Ferrari, Riccardo
    van Wingerden, Jan-Willem
    2022 AMERICAN CONTROL CONFERENCE, ACC, 2022, : 5271 - 5276
  • [7] Wind shear estimation model using load measurement of wind turbine tower and surrogate model
    Namura, Nobuo
    WIND ENERGY, 2020, 23 (02) : 327 - 339
  • [8] Load reduction of a monopile wind turbine tower using optimal tuned mass dampers
    Tong, Xin
    Zhao, Xiaowei
    Zhao, Shi
    INTERNATIONAL JOURNAL OF CONTROL, 2017, 90 (07) : 1283 - 1298
  • [9] Structural Behavior Analysis of UHPC Hybrid Tower for 3-MW Super Tall Wind Turbine Under Rated Wind Load
    Xiangguo Wu
    Xuesen Zhang
    Hom Bahadur Bhattarai
    Hyeon-Jong Hwang
    Jing Yang
    Soonpil Kang
    International Journal of Concrete Structures and Materials, 2022, 16
  • [10] Empirical wind turbine load distributions using field data
    Agarwal, Puneet
    Manuel, Lance
    JOURNAL OF OFFSHORE MECHANICS AND ARCTIC ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (01):