THE ADVANTAGES OF THE IMPLEMENTATION OF DIGITAL FLOW IN THE WORKING TIME MANAGEMENT OF DENTAL PROSTHESES RESTORATIONS

被引:0
|
作者
Novac, Andreea Codruta [1 ,2 ]
Pop, Daniela Maria [1 ,2 ]
Tanase, Alina [1 ,2 ,3 ]
Zaharia, Cristian [1 ,2 ]
Craciunescu, Emanuela Lidia [1 ,2 ]
Rominu, Mihai [1 ,2 ]
Negrutiu, Meda Lavinia [1 ,2 ]
Duma, Virgil-Florin [4 ]
Sinescu, Cosmin [1 ,2 ]
机构
[1] Victor Babes Univ Med & Pharm Timisoara, 2 Piata Eftimie Murgu, Timisoara 300041, Romania
[2] Victor Babes Univ Med & Pharm Timisoara, Fac Dent Med, Res Ctr Dent Med Using Convent & Alternat Technol, Dept Prostheses Technol & Dent Mat, 9 Revolutiei 1989 Ave, Timisoara 300070, Romania
[3] Victor Babes Univ Med & Pharm Timisoara, Fac Dent Med, Dept Profess Legislat Dent Med, Timisoara, Romania
[4] Aurel Vlaicu Univ Arad, Optomechatron Grp 3OM, 77 Revolutiei Ave, Arad 310130, Romania
来源
关键词
conventional impression; digital impression; working time evaluation; fidelity;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of the study is to perform a comparison between conventional impression versus intraoral and extraoral scanning, plaster models compared to virtual and printed models, in terms of working time and fidelity. Material and method: The study evaluates two groups of practitioners: 30 dentists and 30 dental technicians, regarding registration and reproduction of the prosthetic field. The time required to perform the operations was evaluated in relation to variables that can influence the final results. Conventional impressions were monophasic and biphasic. In the digital flow, an intraoral scanner (Medit, i700) and a laboratory scanner (Medit T310) were used. Also, a printing machine (Elegoo Saturn) was used to print the models. Results and discussions: The average time allocated for conventional impressions is between 8min and 20sec and 25min and 40sec. The scanning time varied between 5 min 30 sec and 12 min 40 sec. Conclusions: The digital impression requires less working time compared to the conventional one, the latter cannot be completely abandoned, at least in terms of mobile prostheses. The fidelity of the prosthodontic field reproduction influences the adaptation of the restorations.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 14 条
  • [1] Use of digital impression systems with intraoral scanners for fabricating restorations and fixed dental prostheses
    Takeuchi, Yoshimasa
    Koizumi, Hiroyasu
    Furuchi, Mika
    Sato, Yohei
    Ohkubo, Chikahiro
    Matsumura, Hideo
    JOURNAL OF ORAL SCIENCE, 2018, 60 (01) : 1 - 7
  • [2] Implementation of a Working Time Recording System as a Digital Management Tool in Public Administration
    Khorsand, Phuong Ngoc Nguyen-Hadi
    Peracek, Tomas
    ADMINISTRATIVE SCIENCES, 2023, 13 (12)
  • [3] Implementation of computer-guided implant planning using digital scanning technology for restorations supported by conical abutments: A dental technique
    Albiero, Alberto Maria
    Benato, Renato
    Momic, Stefano
    Degidi, Marco
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (05): : 720 - 726
  • [4] Time efficiency and cost analysis between digital and conventional workflows for the fabrication of fixed dental prostheses: A systematic review
    Bessadet, Marion
    Drancourt, Noemie
    El Osta, Nada
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (01): : 71 - 84
  • [5] The link between knowledge management and the implementation of a working time recording system in the home office
    Hadi Khorsand, Phuong Ngoc Nguyen-
    Peracek, Tomas
    Bajzikova, Lubica
    COGENT SOCIAL SCIENCES, 2023, 9 (02):
  • [6] Flow Management of First-Time Orders: A Dental Office Case Study
    Majewski, A.
    Merkisz-Guranowska, A.
    Czarnota, K.
    JOURNAL OF ENGINEERING SCIENCES-UKRAINE, 2022, 9 (02): : B7 - B16
  • [7] Patient preference and clinical working time between digital scanning and conventional impression making for implant- supported prostheses: A systematic review and meta-analysis
    Manicone, Paolo Francesco
    De Angelis, Paolo
    Rella, Edoardo
    Damis, Giovanni
    D'addona, Antonio
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 589 - 596
  • [8] Time-efficiency and cost-analysis comparing three digital workflows for treatment with monolithic zirconia implant fixed dental prostheses: A double-blinded RCT
    Joda, Tim
    Gintaute, Aiste
    Bragger, Urs
    Ferrari, Marco
    Weber, Karin
    Zitzmann, Nicola U.
    JOURNAL OF DENTISTRY, 2021, 113
  • [9] Architecture, application and implementation of a digital twin of the RFID-enabled material flow in real-time for automotive intralogistics
    Knapp, Henriette
    Romagnoli, Giovanni
    Uckelmann, Dieter
    INTERNATIONAL JOURNAL OF RF TECHNOLOGIES-RESEARCH AND APPLICATIONS, 2023, 13 (01) : 53 - 90
  • [10] Implementation of Real-time Optimal Power Flow Management System on Hybrid AC/DC Smart Microgrid
    Salehi, Vahid
    Mohamed, Ahmed
    Mohammed, Osama A.
    2012 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2012,