Characterization Method for Digital Correlator of Interferometric Radiometers Based on Correlated Noise Source

被引:0
|
作者
Liu, Jiayi [1 ,2 ]
Han, Donghao [1 ]
Guo, Xi [3 ]
Niu, Lijie [1 ]
Liu, Hao [1 ]
机构
[1] Chinese Acad Sci, Natl Space Sci Ctr, Key Lab Microwave Remote Sensing, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Correlator test; digital correlator; microwave interferometric radiometer; CALIBRATION;
D O I
10.1109/LGRS.2023.3299292
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Digital correlator is the central signal processing unit for an interferometric radiometer system. The core function of the digital correlator is to quantitatively measure the correlation coefficients of all the receiver output combination pairs, and then generate the visibility functions together with the system noise temperatures obtained by single-channel total-power measurements. In this letter, a comprehensive quantitative characterization method is proposed for a 30-channel, three-level quantized digital correlator unit (DCU), which will be used for the microwave imager combined active and passive (MICAP) C- and K-bands radiometers, on-board Chinese ocean salinity mission (COSM). First, several key performance characteristics of DCU, including correlation offset and correlation efficiency, are defined and discussed based on a segmented error model. Second, a test platform based on an arbitrary waveform generator (AWG) is established and applied for the test and evaluation of the DCU engineering model (EM). Orthogonal in-phase and quadrature bandlimited noise signals are generated via a newly proposed approach based on Hilbert transform, facilitating the joint tests of correlation efficiency and phase error. Moreover, the influences of the correlator's input power level on correlation offset and correlation efficiency are also investigated during the test of DCU. DCU test results show that the correlation offset is smaller than -40 dB, the correlation efficiency is better than 0.996, and the phase error is less than 5 degrees. The result can provide an important reference for the digital correlator test in COSM.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [1] Characterization of the aquarius and juno radiometers using a programmable digital noise source
    Peng, Jinzheng
    Ruf, Christopher S.
    Brown, Shannon
    Piepmeier, Jeffrey
    IGARSS: 2007 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-12: SENSING AND UNDERSTANDING OUR PLANET, 2007, : 2416 - +
  • [2] A correlated noise calibration standard for interferometric, polarimetric, and autocorrelation microwave radiometers
    Ruf, CS
    Li, JK
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2003, 41 (10): : 2187 - 2196
  • [3] A METHOD OF CALIBRATING CENTIMETRIC RADIOMETERS USING A STANDARD NOISE SOURCE
    HEY, JS
    HUGHES, VA
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1958, 46 (01): : 119 - 121
  • [4] Calibration Method for Fully Polarimetric Microwave Radiometers Using the Correlated Noise Calibration Standard
    Peng, Jinzheng
    Ruf, Christopher S.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2008, 46 (10): : 3087 - 3097
  • [5] Researching the generation method of digital noise source
    Liu, ZW
    Qu, J
    Ji, R
    Xian, HP
    Ren, TY
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 2, 2005, : 203 - 206
  • [6] Research on the readout noise suppression method for digital correlated double sampling
    Wei Duan
    Qian Song
    Ming-Zhi Wei
    Zhao-Wang Zhao
    Wei Wang
    Yu-Heng Zhang
    Zhi-Wei Feng
    Research in Astronomy and Astrophysics, 2021, 21 (01) : 129 - 137
  • [7] Research on the readout noise suppression method for digital correlated double sampling
    Duan, Wei
    Song, Qian
    Wei, Ming-Zhi
    Zhao, Zhao-Wang
    Wang, Wei
    Zhang, Yu-Heng
    Feng, Zhi-Wei
    RESEARCH IN ASTRONOMY AND ASTROPHYSICS, 2021, 21 (01)
  • [8] An FFT-Based CLEAN Deconvolution Method for Interferometric Microwave Radiometers With Spatially Variable Beam Pattern
    Sugihara El Maghraby, Ahmed Kiyoshi
    Park, Hyuk
    Camps, Adriano
    Grubisic, Angelo
    Colombo, Camilla
    Tatnall, Adrian
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2021, 18 (02) : 341 - 345
  • [9] Validation of a wind noise source characterization method for vehicle interior noise prediction
    Blanchet, D.
    Golota, A.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2014) AND INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2014), 2014, : 241 - 256
  • [10] Reduced spatially correlated noise influence using subspace source localization method FINES
    Ding, L
    Xu, XL
    Xu, B
    Ni, Y
    He, B
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 4393 - 4396