Evaluation and correlation of patient movement during online adaptive radiotherapy with CBCT and a surface imaging system

被引:3
|
作者
Stanley, Dennis N. [1 ,3 ]
Covington, Elizabeth [1 ,2 ]
Harms, Joseph [1 ]
Pogue, Joel [1 ]
Cardenas, Carlos E. [1 ]
Popple, Richard A. [1 ]
机构
[1] Univ Alabama Birmingham, Dept Radiat Oncol, Birmingham, AL USA
[2] Michigan Med, Dept Radiat Oncol, Ann Arbor, MI USA
[3] Univ Alabama Birmingham, Dept Radiat Oncol, 1719 6th Ave S, Birmingham, AL 35294 USA
关键词
IDENTIFY; online adaptive radiotherapy; optical surface imaging; patient movement; SGRT; ACCURACY;
D O I
10.1002/acm2.14133
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: With the clinical implementation of kV-CBCT-based daily online-adaptive radiotherapy, the ability to monitor, quantify, and correct patient movement during adaptive sessions is paramount. With sessions lasting between 20-45 min, the ability to detect and correct for small movements without restarting the entire session is critical to the adaptive workflow and dosimetric outcome. The purpose of this study was to quantify and evaluate the correlation of observed patient movement with machine logs and a surface imaging (SI) system during adaptive radiation therapy. Methods: Treatment machine logs and SGRT registration data log files for 1972 individual sessions were exported and analyzed. For each session, the calculated shifts from a pre-delivery position verification CBCT were extracted from the machine logs and compared to the SGRT registration data log files captured during motion monitoring. The SGRT calculated shifts were compared to the reported shifts of the machine logs for comparison for all patients and eight disease site categories. Results: The average (+/- STD) net displacement of the SGRT shifts were 2.6 +/- 3.4 mm, 2.6 +/- 3.5 mm, and 3.0 +/- 3.2 in the lateral, longitudinal, and vertical directions, respectively. For the treatment machine logs, the average net displacements in the lateral, longitudinal, and vertical directions were 2.7 +/- 3.7 mm, 2.6 +/- 3.7 mm, and 3.2 +/- 3.6 mm. The average difference (Machine-SGRT) was -0.1 +/- 1.8 mm, 0.2 +/- 2.1 mm, and -0.5 +/- 2.5 mm for the lateral, longitudinal, and vertical directions. On average, a movement of 5.8 +/- 5.6 mm and 5.3 +/- 4.9 mm was calculated prior to delivery for the CBCT and SGRT systems, respectively. The Pearson correlation coefficient between CBCT and SGRT shifts was r = 0.88. The mean and median difference between the treatment machine logs and SGRT log files was less than 1 mm for all sites. Conclusion: Surface imaging should be used to monitor and quantify patient movement during adaptive radiotherapy.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Evaluation of Patient Movement During Online Adaptive Radiotherapy with CBCT and a Surface Imaging System
    Stanley, D.
    Cardenas, C.
    Belliveau, J.
    Popple, R.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E491 - E491
  • [2] Evaluation of the DIRs driving a CBCT-guided online adaptive radiotherapy system
    Quinn, A.
    Kipritidis, J.
    Booth, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1290 - S1291
  • [3] Intrafraction prostate motion during CBCT-guided online adaptive radiotherapy
    Zwart, L.
    Jasper, J.
    Vrieze, E.
    ten Asbroek, L.
    Ong, F.
    Koch, S.
    van Dieren, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1491 - S1491
  • [4] Clinical evaluation of surface-imaging system for patient positioning during breast cancer radiotherapy
    Karle, H.
    Tiogueu, C.
    Toujami, S.
    Grossmann, S.
    Schmidberger, H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S250 - S250
  • [5] Evaluation of CBCT-based auto contouring for online adaptive radiotherapy of cervical cancer
    Badey, A.
    Arnaud, A.
    Bigou, A.
    De Rauglaudre, G.
    Nagy, A.
    Vieillevigne, L.
    Khamphan, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1331 - S1332
  • [6] Towards online patient imaging during helical radiotherapy
    L. Yu
    C. M. Poole
    C. M. Lancaster
    S. R. Sylvander
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 119 - 128
  • [7] Towards online patient imaging during helical radiotherapy
    Yu, L.
    Poole, C. M.
    Lancaster, C. M.
    Sylvander, S. R.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (01) : 119 - 128
  • [8] A novel surface imaging system for patient positioning and surveillance during radiotherapy A phantom study and clinical evaluation
    Stieler, F.
    Wenz, F.
    Shi, M.
    Lohr, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (11) : 938 - 944
  • [9] CBCT and MRI-based workflows for online adaptive radiotherapy
    Behrens, C. P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S857 - S857
  • [10] Clinical evaluation of a commercial surface-imaging system for patient positioning in radiotherapy
    Stieler, F.
    Wenz, F.
    Scherrer, D.
    Bernhardt, M.
    Lohr, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (12) : 1080 - 1084