Effect of Roof Design Configurations on Natural Ventilation with an Obstacle Inside the Building Model

被引:1
|
作者
Moey, Lip Kean [1 ]
Wan, Kian Shen [2 ]
Tai, Vin Cent [1 ]
Go, Tze Fong [3 ]
Chong, Perk Lin [4 ]
机构
[1] SEGi Univ, Fac Engn Built Environm & Informat Technol, Ctr Modelling & Simulat, Selangor, Malaysia
[2] SEGi Univ, Fac Engn Built Environm & Informat Technol, Selangor, Malaysia
[3] SEGi Univ, Fac Engn Built Environm & Informat Technol, Ctr Adv Mat & Intelligent Mfg, Selangor 47810, Malaysia
[4] Teesside Univ, Sch Comp Engn & Digital Technol, Middlesbrough TS1 3BX, England
来源
INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING | 2023年 / 15卷 / 07期
关键词
Natural ventilation; roof ventilation; CFD; obstacle height; dimensionless flowrate; DRIVEN CROSS VENTILATION; OPENING POSITIONS; IMPACT; CFD; ANGLE; FLOW;
D O I
10.30880/ijie.2023.15.07.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Roof shape, roof angle, and internal obstacle are some of the factors that have a substantial impact on building's ventilation performance. However, previous roof ventilation studies have not considered the influence of internal obstacle which can affect the overall building's ventilation performance. For this study, CFD was used to study the effect of roof design configurations on natural ventilation with an obstacle inside the building model. The numerical simulation was carried out by using steady RANS equation specifically the Standard k-epsilon with enhanced wall treatment. A total of 40 simulation cases were carried out. The study considered two roof shapes mainly the sawtooth roof and the saltbox roof with varying roof angle which were 10o, 20o, 30o, and 40o. Internal obstacles with various height were further added into the simulation cases. Next, grid sensitivity analysis was carried out using Grid Convergence Index (GCI) and Factor of two of observations (FAC2) analysis was carried out as model verification method to ensure a reliable simulation result. Based on the results, it is found that airflow characteristics such as wind speed, distribution of pressure coefficient, and flowrate of an isolated building are strongly dependent on the roof shape and roof angle. Next, the dimensionless flowrate (DFR) is measured to be highest with largest roof angle while lowest with smaller roof angle. Furthermore, the DFR of a building with internal obstacle is lower than that without an internal obstacle due to blockage of incoming air. Moreover, the results show that the sawtooth roof outperforms the saltbox roof in terms of measured parameter. Finally, the study concluded that an isolated building with higher roof angle and without an internal obstacle leads to the best dimensionless flowrate throughout the building.
引用
收藏
页码:11 / 23
页数:13
相关论文
共 50 条
  • [1] Effect of gable roof with various roof pitches and obstacle heights on natural ventilation performance for an isolated building
    Zobaied, A. A.
    Tai, V. C.
    Go, T. F.
    Chong, P. L.
    Moey, L. K.
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2022, 16 (03) : 9033 - 9042
  • [2] Effect of Gable Roof Angle on Natural Ventilation for an Isolated Building
    Moey, Lip Kean
    Kong, Man Fai
    Tai, Vin Cent
    Go, Tze Fong
    Adam, Nor Mariah
    JORDAN JOURNAL OF MECHANICAL AND INDUSTRIAL ENGINEERING, 2021, 15 (03): : 291 - 300
  • [3] New configurations of a roof solar collector maximizing natural ventilation
    Hirunlabh, J
    Wachirapuwadon, S
    Pratinthong, N
    Khedari, J
    BUILDING AND ENVIRONMENT, 2001, 36 (03) : 383 - 391
  • [4] Effects of roof configuration on natural ventilation for an isolated building
    Moey, L. K.
    Kong, M. F.
    Tai, V. C.
    Go, T. F.
    Adam, N. M.
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2021, 15 (03) : 8379 - 8389
  • [5] Building Design Effect on Indoor Natural Ventilation of Tropical Houses
    Abd Wahab, Izudinshah
    Abd Aziz, Hazri
    Abd Salam, Nur Nasuha
    INTERNATIONAL JOURNAL OF SUSTAINABLE CONSTRUCTION ENGINEERING AND TECHNOLOGY, 2019, 10 (01): : 23 - 33
  • [6] Experimental investigations of the indoor natural ventilation for different building configurations and incidences
    Bady, Mahmoud
    Kato, Shinsuke
    Takahashi, Takeo
    Huang, Hong
    BUILDING AND ENVIRONMENT, 2011, 46 (01) : 65 - 74
  • [7] Window and roof configurations for comfort ventilation - A study modelling the influence of design elements and passive design to improve ventilation in tropical conditions
    Kindangen, JI
    BUILDING RESEARCH AND INFORMATION, 1997, 25 (04): : 218 - 225
  • [8] Natural Ventilation Design Attributes Application Effect on Indoor Natural Ventilation Performance of a Double Storey Single Unit Residential Building
    Abd Wahabi, Lzudinshah
    Ismaili, Lokman Hakim
    Abdullah, Abd Halid
    Rahmati, Muhamad Hanafi
    Abd Salami, Nur Nasuha
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2018, 10 (02): : 7 - 12
  • [9] A venturi-shaped roof for wind-induced natural ventilation of buildings: Wind tunnel and CFD evaluation of different design configurations
    van Hooff, T.
    Blocken, B.
    Aanen, L.
    Bronsema, B.
    BUILDING AND ENVIRONMENT, 2011, 46 (09) : 1797 - 1807
  • [10] Study on effect of natural ventilation for houses with different opening configurations
    Li, Yanfeng
    Hou, Conglan
    Li, Junmei
    Lin, Jie
    Yang, Chao
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 282 - 287