Mid-term clinical and echocardiographic results of the INSPIRIS RESILIA aortic valve: a retrospective comparison to the Magna Ease

被引:5
|
作者
Bernard, Jeremy [1 ]
Georges, Gabriel [2 ]
Hecht, Sebastien
Pibarot, Philippe [1 ]
Clavel, Marie-Annick [1 ]
Babaki, Shervin [3 ]
Kalavrouziotis, Dimitri [2 ]
Mohammadi, Siamak [2 ,4 ]
机构
[1] Univ Laval, Quebec Heart & Lung Inst, Inst Univ Cardiol & Pneumol Quebec, Cardiol Div, Quebec City, PQ, Canada
[2] Univ Laval, Quebec Heart & Lung Inst, Inst Univ Cardiol & Pneumol Quebec, Cardiac Surg Div, Quebec City, PQ, Canada
[3] Univ Laval, Quebec Heart & Lung Inst, Inst Univ Cardiol & Pneumol Quebec, Res Div, Quebec City, PQ, Canada
[4] Quebec Heart & Lung Inst, 2725 Chemin Ste Foy, Quebec City, PQ G1V 4G5, Canada
基金
加拿大健康研究院;
关键词
Surgical aortic valve replacement; INSPIRIS RESILIA; Magna Ease; Patient-prosthesis mismatch; Structural valve deterioration; Transvalvular gradient; SURGICAL EXPLANTATION; THORACIC-SURGERY; OUTCOMES;
D O I
10.1093/icvts/ivad117
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: The INSPIRIS aortic valve combines the RESILIA proprietary tissue preservation process and an expandable stent frame to benefit future transcatheter valve-in-valve procedures. As the INSPIRIS valve became commercially available in 2017, mid-term outcome reports are scarce. We aimed to evaluate mid-term safety and echocardiographic performance of the INSPIRIS valve in comparison to its predecessor, the Carpentier Edwards Perimount Magna Ease (ME). METHODS: This study was a retrospective single-centre study. Clinical results included early postoperative outcomes, mid-term mortality and readmission for cardiovascular cause or stroke. Echocardiographic follow-up (FU) was performed at discharge and 1-3, 6, 12 and 24 months. Clinical end point analyses were accomplished with a propensity score matching analysis and FU echocardiographic data comparisons using pairwise analyses and linear mixed-effect models. RESULTS: We included 953 patients who received an INSPIRIS (n = 488) or ME (n = 463) bioprosthesis between January 2018 and July 2021. In the matched population (n = 217 per group), no significant difference in short-term outcomes was observed, survival was similar at 30 months (INSPIRIS: 94% vs ME: 91%, P = 0.89), but freedom from readmission was higher in the INSPIRIS group (94% vs 86%, P = 0.014). INSPIRIS valves had a lower gradient at discharge (similar to 10 vs 14 mmHg, P < 0.001), 1-3 months (similar to 10 vs 12 mmHg, P < 0.001) and 24 months (similar to 11 vs 17 mmHg, P < 0.001) in paired analyses and significantly lower evolution of mean transvalvular gradients compared to ME. CONCLUSIONS: This study represents the largest comparative evaluation of the INSPIRIS to the ME valves, which demonstrated safe clinical outcomes and favourable haemodynamic performance at 2 years. Long-term FU is underway.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Early results of the Resilia Inspiris aortic valve in the old age patients - a retrospective comparison with the Carpentier Edwards Magna Ease
    Shala, Magjun
    Niclauss, Lars
    JOURNAL OF CARDIOVASCULAR AND THORACIC RESEARCH, 2020, 12 (03) : 222 - 226
  • [2] Magna ease bioprosthetic aortic valve: mid-term haemodynamic outcomes in 1126 patients
    Thorp, Stephen D.
    Khazaal, Jawad
    Yu, Grace
    Parker, Jessica L.
    Timek, Tomasz A.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 32 (06) : 839 - 845
  • [3] Short- and Mid-Term Results of Pulmonary Valve Replacement with the Inspiris Valve
    Ragheb, Daniel K.
    Martin, Elisabeth
    Jaggi, Ayush
    Lui, George K.
    Maskatia, Shiraz A.
    Ma, Michael
    Hanley, Frank L.
    McElhinney, Doff B.
    ANNALS OF THORACIC SURGERY, 2024, 117 (06): : 1203 - 1210
  • [4] Perioperative and Echocardiographic Considerations for the Inspiris Resilia Aortic Valve-Current and Future
    Vanneman, Matthew W.
    Dalia, Adam A.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2020, 34 (10) : 2807 - 2812
  • [5] Mid-term follow-up after aortic valve replacement with the Carpentier Edwards Magna Ease prosthesis
    Taufiek K. Rajab
    Jason M. Ali
    Jules Hernández-Sánchez
    Jennifer Mackie
    Vincenzo Grimaudo
    Silvia Sinichino
    Christine Mills
    Bushra Rana
    John Dunning
    Yasir Abu-Omar
    Journal of Cardiothoracic Surgery, 15
  • [6] Mid-term follow-up after aortic valve replacement with the Carpentier Edwards Magna Ease prosthesis
    Rajab, Taufiek K.
    Ali, Jason M.
    Hernandez-Sanchez, Jules
    Mackie, Jennifer
    Grimaudo, Vincenzo
    Sinichino, Silvia
    Mills, Christine
    Rana, Bushra
    Dunning, John
    Abu-Omar, Yasir
    JOURNAL OF CARDIOTHORACIC SURGERY, 2020, 15 (01)
  • [7] Late clinical and echocardiographic results with the Magna Ease© pericardial aortic bioprosthesis
    Anselmi, Amedeo
    Aymami, Marie
    Tomasi, Jacques
    DAlessandro, Gemma
    Langanay, Thierry
    Corbineau, Herve
    Mancini, Julien
    Flecher, Erwan
    Verhoye, Jean-Philippe
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2024, 65 (02)
  • [8] EARLY AND MID-TERM RESULTS FROM THE RESILIA AORTIC TISSUE VALVE ITALIAN REGISTRY (RES-ITA)
    D'Ascoli, R.
    Prestipino, F.
    Luzi, G.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2023, 25 : D17 - D17
  • [9] EARLYAND MID-TERM RESULTS FROM THE RESILIA AORTIC TISSUE VALVE ITALIAN REGISTRY (RES-ITA)
    Manzan, E.
    Prestipino, F.
    D'Ascoli, R.
    Musumeci, F.
    Di Credico, G.
    Di Eusanio, M.
    Faggian, G.
    Glauber, M.
    Merlo, M.
    Polvani, G.
    Luzi, G.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0G) : G113 - G113
  • [10] Artificial chordae for mitral valve repair: Mid-term clinical and echocardiographic results
    Risteski, P. S.
    Aybek, T.
    Dzemali, O.
    Doss, M.
    Scherer, M.
    Dogan, S.
    Moritz, A.
    THORACIC AND CARDIOVASCULAR SURGEON, 2007, 55 (04): : 239 - 244