Conformable ultrasound breast patch for deep tissue scanning and imaging

被引:36
|
作者
Du, Wenya [1 ]
Zhang, Lin [1 ]
Suh, Emma [1 ,2 ]
Lin, Dabin [3 ]
Marcus, Colin [1 ,4 ]
Ozkan, Lara [1 ,4 ]
Ahuja, Avani [1 ,2 ]
Fernandez, Sara [1 ,5 ]
Shuvo, Ikra Iftekhar [1 ]
Sadat, David [1 ]
Liu, Weiguo [3 ]
Li, Fei [6 ]
Chandrakasan, Anantha P. [4 ]
Ozmen, Tolga [7 ]
Dagdeviren, Canan [1 ]
机构
[1] MIT, Media Lab, Cambridge, MA 02139 USA
[2] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[3] Xian Technol Univ, Sch Optoelect Engn, Xian 710021, Peoples R China
[4] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[5] MIT, Dept Mat Sci & Engn, Cambridge, MA 02142 USA
[6] Xi An Jiao Tong Univ, Sch Elect Sci & Engn, Elect Mat Res Lab, Xian 710049, Peoples R China
[7] Harvard Med Sch, Massachusetts Gen Hosp, Div Surg Oncol, Boston, MA 02114 USA
关键词
CANCER; TRANSDUCERS; MAMMOGRAPHY; PERFORMANCE; CERAMICS; CRYSTALS; DESIGN; BODY; SIZE;
D O I
10.1126/sciadv.adh5325
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ultrasound is widely used for tissue imaging such as breast cancer diagnosis; however, fundamental challenges limit its integration with wearable technologies, namely, imaging over large-area curvilinear organs. We introduced a wearable, conformable ultrasound breast patch (cUSBr-Patch) that enables standardized and reproducible image acquisition over the entire breast with less reliance on operator training and applied transducer compression. A nature-inspired honeycomb-shaped patch combined with a phased array is guided by an easy-to-operate tracker that provides for large-area, deep scanning, and multiangle breast imaging capability. The in vitro studies and clinical trials reveal that the array using a piezoelectric crystal [Yb/Bi-Pb(In1/2Nb1/2)O-3-Pb(Mg1/3Nb2/3)O-3-PbTiO3] (Yb/Bi-PIN-PMN-PT) exhibits a sufficient contrast resolution (similar to 3 dB) and axial/lateral resolutions of 0.25/1.0 mm at 30 mm depth, allowing the observation of small cysts (similar to 0.3 cm) in the breast. This research develops a first-of-its-kind ultrasound technology for breast tissue scanning and imaging that offers a noninvasive method for tracking real-time dynamic changes of soft tissue.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] From bedside to portable and wearable: development of a conformable ultrasound patch for deep breast tissue imaging
    Burgess, Mark T.
    Gluskin, Jill
    Pinker, Katja
    MOLECULAR ONCOLOGY, 2023, 17 (10) : 1947 - 1949
  • [2] Conformable Ultrasound Breast Patch - The Future of Breast Cancer Screening?
    Giannakou, Andreas
    Dagdeviren, Canan
    Ozmen, Tolga
    EUROPEAN JOURNAL OF BREAST HEALTH, 2025, 21 (01)
  • [3] Developing ultrasound optical tomography for deep tissue imaging of the breast
    Bukarte, E.
    Zabiliute-Karaliune, A.
    Ruchkina, M.
    Kinos, A.
    Reistad, N.
    Rippe, L.
    Swartling, J.
    Kovacs, L.
    Kis, Z.
    Lengyel, K.
    Szaller, Z.
    Chaudhry, N.
    Bakic, P. R.
    Zackrisson, S.
    Kroll, S.
    17TH INTERNATIONAL WORKSHOP ON BREAST IMAGING, IWBI 2024, 2024, 13174
  • [4] Slow light for deep tissue imaging with ultrasound modulation
    Zhang, Huiliang
    Sabooni, Mahmood
    Rippe, Lars
    Kim, Chulhong
    Kroell, Stefan
    Wang, Lihong V.
    Hemmer, Philip R.
    APPLIED PHYSICS LETTERS, 2012, 100 (13)
  • [5] Opto-ultrasound imaging in vivo in deep tissue
    Si, Ke
    YanXu
    Zheng, Yao
    Zhu, Xinpei
    Gong, Wei
    8TH INTERNATIONAL CONFERENCE ON ADVANCED INFOCOMM TECHNOLOGY (ICAIT 2015), 2016, 679
  • [6] A conformable phased-array ultrasound patch for bladder volume monitoring
    Lin Zhang
    Colin Marcus
    Dabin Lin
    David Mejorado
    Scott Joseph Schoen
    Theodore T. Pierce
    Viksit Kumar
    Sara V. Fernandez
    David Hunt
    Qian Li
    Ikra Iftekhar Shuvo
    David Sadat
    Wenya Du
    Hannah Edenbaum
    Li Jin
    Weiguo Liu
    Yonina C. Eldar
    Fei Li
    Anantha P. Chandrakasan
    Anthony E. Samir
    Canan Dagdeviren
    Nature Electronics, 2024, 7 : 77 - 90
  • [7] A conformable phased-array ultrasound patch for bladder volume monitoring
    Zhang, Lin
    Marcus, Colin
    Lin, Dabin
    Mejorado, David
    Schoen Jr, Scott Joseph
    Pierce, Theodore T.
    Kumar, Viksit
    Fernandez, Sara V.
    Hunt, David
    Li, Qian
    Shuvo, Ikra Iftekhar
    Sadat, David
    Du, Wenya
    Edenbaum, Hannah
    Jin, Li
    Liu, Weiguo
    Eldar, Yonina C.
    Li, Fei
    Chandrakasan, Anantha P.
    Samir, Anthony E.
    Dagdeviren, Canan
    NATURE ELECTRONICS, 2024, 7 (01) : 77 - 90
  • [8] A Conformable Ultrasound Patch for Cavitation-Enhanced Transdermal Cosmeceutical Delivery
    Yu, Chia-Chen
    Shah, Aastha
    Amiri, Nikta
    Marcus, Colin
    Nayeem, Md Osman Goni
    Bhayadia, Amit Kumar
    Karami, Amin
    Dagdeviren, Canan
    ADVANCED MATERIALS, 2023, 35 (23)
  • [9] Tissue-Type Classification With Uncertainty Quantification of Microwave and Ultrasound Breast Imaging: A Deep Learning Approach
    Mojabi, Pedram
    Khoshdel, Vahab
    Lovetri, Joe
    IEEE ACCESS, 2020, 8 (08): : 182092 - 182104
  • [10] Breast Tissue Mimicking Phantoms for Combined Microwave and Ultrasound Imaging
    Li, Siyun
    Fear, Elise
    Curiel, Laura
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,