Feasibility of transient nuclear Overhauser effect imaging in brain at 7 T

被引:5
|
作者
Kumar, Dushyant [1 ]
Benyard, Blake [1 ]
Soni, Narayan Datt [1 ]
Swain, Anshuman [1 ]
Wilson, Neil [1 ]
Reddy, Ravinder [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA USA
基金
美国国家卫生研究院;
关键词
lipid imaging; myelin imaging; nuclear Overhauser effect; NOE; selective inversion recovery; transient nuclear Overhauser effect; MAGNETIZATION-TRANSFER; QUANTITATIVE INTERPRETATION; LIPID-PEROXIDATION; OXIDATIVE STRESS; WATER SATURATION; FATTY-ACIDS; RELAXATION; NMR; EXCHANGE; MYELIN;
D O I
10.1002/mrm.29519
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The nuclear Overhauser effect (NOE) quantification from the steady-state NOE imaging suffers from multiple confounding non-NOE-specific sources, including direct saturation, magnetization transfer, and relevant chemical exchange species, and is affected by B-0 and B-1(+) inhomogeneities. The B-0-dependent and B-1(+)-dependent data needed for deconvolving these confounding effects would increase the scan time substantially, leading to other issues such as patient tolerability. Here, we demonstrate the feasibility of brain lipid mapping using an easily implementable transient NOE (tNOE) approach. Methods This 7T study used a frequency-selective inversion pulse at a range of frequency offsets between 1.0 and 5.0 parts per million (ppm) and -5.0 and -1.0 ppm relative to bulk water peak. This was followed by a fixed/variable mixing time and then a single-shot 2D turbo FLASH readout. The feasibility of tNOE measurements is demonstrated on bovine serum albumin phantoms and healthy human brains. Results The tNOE measurements from bovine serum albumin phantoms were found to be independent of physiological pH variations. Both bovine serum albumin phantoms and human brains showed broad tNOE contributions centered at approximately -3.5 ppm relative to water peak, with presumably aliphatic moieties in lipids and proteins being the dominant contributors. Less prominent tNOE contributions of approximately +2.5 ppm relative to water, presumably from aromatic moieties, were also detected. These aromatic signals were free from any CEST signals. Conclusion In this study, we have demonstrated the feasibility of tNOE in human brain at 7 T. This method is more scan-time efficient than steady-state NOE and provides NOE measurement with minimal confounders.
引用
收藏
页码:1357 / 1367
页数:11
相关论文
共 50 条
  • [1] Nuclear Overhauser enhancement (NOE) imaging in the human brain at 7 T
    Jones, Craig K.
    Huang, Alan
    Xu, Jiadi
    Edden, Richard A. E.
    Schaer, Michael
    Hua, Jun
    Oskolkov, Nikita
    Zaca, Domenico
    Zhou, Jinyuan
    McMahon, Michael T.
    Pillai, Jay J.
    van Zijl, Peter C. M.
    NEUROIMAGE, 2013, 77 : 114 - 124
  • [2] Imaging of nuclear Overhauser enhancement at 7 and 3T
    Shen, Yuanyu
    Xiao, Gang
    Shen, Zhiwei
    Zhang, Xiaolei
    Tang, Xiangyong
    Hu, Wei
    Zhang, Zhiyan
    Guan, Jitian
    Wu, Renhua
    NMR IN BIOMEDICINE, 2017, 30 (09)
  • [3] Repeatability of 31P MRSI in the human brain at 7T with and without the nuclear Overhauser effect
    Lagemaat, Miriam W.
    van de Bank, Bart L.
    Sati, Pascal
    Li, Shizhe
    Maas, Marnix C.
    Scheenen, Tom W. J.
    NMR IN BIOMEDICINE, 2016, 29 (03) : 256 - 263
  • [4] High-resolution imaging of magnetisation transfer and nuclear Overhauser effect in the human visual cortex at 7 T
    Mougin, Olivier
    Clemence, Matthew
    Peters, Andrew
    Pitiot, Alain
    Gowland, Penny
    NMR IN BIOMEDICINE, 2013, 26 (11) : 1508 - 1517
  • [5] Nuclear Overhauser enhancement imaging at-1.6 ppm in rat brain at 4.7T
    Viswanathan, Malvika
    Kurmi, Yashwant
    Zu, Zhongliang
    MAGNETIC RESONANCE IN MEDICINE, 2023, 91 (02) : 615 - 629
  • [6] Nuclear Overhauser enhancement imaging at-1.6ppm in rat brain at 4.7T
    Viswanathan, Malvika
    Kurmi, Yashwant
    Zu, Zhongliang
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 615 - 629
  • [7] Nuclear Overhauser Enhancement-Mediated Magnetization Transfer Imaging in Glioma with Different Progression at 7 T
    Tang, Xiangyong
    Dai, Zhuozhi
    Xiao, Gang
    Yan, Gen
    Shen, Zhiwei
    Zhang, Tao
    Zhang, Guishan
    Zhuang, Zerui
    Shen, Yuanyu
    Zhang, Zhiyan
    Hu, Wei
    Wu, Renhua
    ACS CHEMICAL NEUROSCIENCE, 2017, 8 (01): : 60 - 66
  • [8] Imaging of nuclear Overhauser enhancement in human brain tumour at 3 Tesla
    Shen, Y.
    Xiao, G.
    Shen, Z.
    Cao, Z.
    Zhang, X.
    Tang, X.
    Hu, W.
    Zhang, Z.
    Wu, R.
    EUROPEAN JOURNAL OF NEUROLOGY, 2016, 23 : 845 - 846
  • [9] 31P MR Spectroscopic Imaging of the Human Prostate at 7 T: T1 Relaxation Times, Nuclear Overhauser Effect, and Spectral Characterization
    Lagemaat, Miriam W.
    Maas, Marnix C.
    Vos, Eline K.
    Bitz, Andreas K.
    Orzada, Stephan
    Weiland, Elisabeth
    van Uden, Mark J.
    Kobus, Thiele
    Heerschap, Arend
    Scheenen, Tom W. J.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 909 - 920
  • [10] SIMULTANEOUS MEASUREMENTS OF NUCLEAR OVERHAUSER EFFECT AND T1
    DUPLAN, JC
    BRIGUET, A
    TETU, G
    DELMAU, J
    JOURNAL OF MAGNETIC RESONANCE, 1978, 31 (03) : 509 - 513