Exhaustive matching of 3D/2D coronary artery structure based on imperfect segmentations

被引:0
|
作者
Wu, Wei [1 ,2 ]
Xie, Hongzhi [3 ]
Zhang, Shuyang [3 ]
Gu, Lixu [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Biomed Engn, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Instituted Med Robot, Shanghai, Peoples R China
[3] Peking Union Med Coll Hosp, Dept Cardiol, Beijing 100005, Peoples R China
关键词
3D; 2D coronary artery; CTA; XCA structure matching; Exhaustive matching algorithm; Imperfect segmentations; REGISTRATION; MODELS;
D O I
10.1007/s11548-023-02933-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeThe 3D/2D coronary artery registration technique has been developed for the guidance of the percutaneous coronary intervention. It introduces the absent 3D structural information by fusing the pre-operative computed tomography angiography (CTA) volume with the intra-operative X-ray coronary angiography (XCA) image. To conduct the registration, an accurate matching of the coronary artery structures extracted from the two imaging modalities is an essential step.MethodsIn this study, we propose an exhaustive matching algorithm to solve this problem. First, by recognizing the fake bifurcations in the XCA image caused by projection and concatenating the fractured centerline fragments, the original XCA topological structure is restored. Then, the vessel segments in the two imaging modalities are removed orderly, which generates all the potential structures to simulate the imperfect segmentation results. Finally, the CTA and XCA structures are compared pairwise, and the matching result is obtained by searching for the structure pair with the minimum similarity score.ResultsThe experiments were conducted based on a clinical dataset collected from 46 patients and comprising of 240 CTA/XCA data pairs. And the results show that the proposed method is very effective, which achieves an accuracy of 0.960 for recognizing the fake bifurcations in the XCA image and an accuracy of 0.896 for matching the CTA/XCA vascular structures.ConclusionThe proposed exhaustive structure matching algorithm is simple and straightforward without any impractical assumption or time-consuming computations. With this method, the influence of the imperfect segmentations is eliminated and the accurate matching could be achieved efficiently. This lays a good foundation for the subsequent 3D/2D coronary artery registration task.
引用
收藏
页码:109 / 117
页数:9
相关论文
共 50 条
  • [1] Exhaustive matching of 3D/2D coronary artery structure based on imperfect segmentations
    Wei Wu
    Hongzhi Xie
    Shuyang Zhang
    Lixu Gu
    International Journal of Computer Assisted Radiology and Surgery, 2024, 19 : 109 - 117
  • [2] A 3D/2D registration of the coronary arteries based consistency matching
    Liu, Songbo
    Liu, Peng
    Li, Zhixun
    Zhang, Yingtao
    Li, Weimin
    Tang, Xianglong
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 38 : 191 - 199
  • [3] 3D Coronary Artery Reconstruction by 2D Motion Compensation Based on Mutual Information
    Li, S.
    Nunes, J. C.
    Toumoulin, C.
    Luo, L.
    IRBM, 2018, 39 (01) : 69 - 82
  • [4] From 2D to 3D geodesic-based garment matching
    Egils Avots
    Meysam Madadi
    Sergio Escalera
    Jordi Gonzàlez
    Xavier Baro
    Paul Pällin
    Gholamreza Anbarjafari
    Multimedia Tools and Applications, 2019, 78 : 25829 - 25853
  • [5] From 2D to 3D geodesic-based garment matching
    Avots, Egils
    Madadi, Meysam
    Escalera, Sergio
    Gonzalez, Jordi
    Baro, Xavier
    Pallin, Paul
    Anbarjafari, Gholamreza
    MULTIMEDIA TOOLS AND APPLICATIONS, 2019, 78 (18) : 25829 - 25853
  • [6] Coronary Artery 3D/2D Registration Based on Particle Swarm Optimization of Contextual Morphological Features
    Liu, Yibo
    Ke, Ting
    ADVANCED INTELLIGENT COMPUTING IN BIOINFORMATICS, PT I, ICIC 2024, 2024, 14881 : 219 - 228
  • [7] Vesselness-based 2D–3D registration of the coronary arteries
    Daniel Ruijters
    Bart M. ter Haar Romeny
    Paul Suetens
    International Journal of Computer Assisted Radiology and Surgery, 2009, 4 : 391 - 397
  • [8] Elliptic polygon based 2D sketch interface for 3D shape matching
    Lee, Jaeho
    Park, Joon Young
    Choi, Young
    COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2007, PT 2, PROCEEDINGS, 2007, 4706 : 706 - 715
  • [9] Oriented Gaussian Mixture Models for Nonrigid 2D/3D Coronary Artery Registration
    Baka, N.
    Metz, C. T.
    Schultz, C. J.
    van Geuns, R. -J.
    Niessen, W. J.
    van Walsum, T.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (05) : 1023 - 1034
  • [10] Feasibility of proximal right coronary artery imaging by 2D and 3D echocardiography in comparison to coronary angiography
    Stoebe S.
    Lange K.
    Pfeiffer D.
    Hagendorff A.
    Echo Research & Practice, 2015, 2 (3): : 73 - 79