Fire risk assessment of Kashan's commercial and shopping centers using fire risk assessment method for engineering (FRAME)

被引:1
|
作者
Rabiei, Hadiseh [1 ]
Zare, Asma [2 ]
Taheri, Somayeh Ahmadian [1 ]
Ebrahimi, Niloofar [1 ]
Tehrani, Ashraf Mazaheri [3 ]
Malakoutikhah, Mahdi [4 ,5 ]
机构
[1] Kashan Univ Med Sci, Sch Hlth, Dept Occupat Hlth Engn, Kashan, Iran
[2] Sirjan Sch Med Sci, Dept Occupat Hlth, Sirjan, Iran
[3] Kashan Univ Med Sci, Sch Hlth, Dept Environm Hlth Engn, Kashan, Iran
[4] Kashan Univ Med Sci, Sch Hlth, Dept Occupat Hlth, Kashan, Iran
[5] Kashan Univ Med Sci, Sch Hlth, Dept Occupat Hlth & Safety, Ghoutb Eravandi Blvd, Kashan, Iran
关键词
fire method for engineering; fire safety; risk assessment; shopping center; SAFETY;
D O I
10.1002/fam.3201
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Commercial buildings are considered as high-risk units in fire due to the existence of expensive equipment and large presence of people with different ages. Therefore, the present study aimed to assess the fire risk of commercial and shopping centers in Kashan using the fire risk assessment method for engineering (FRAME). This cross-sectional study was conducted using FRAME in 15 commercial and shopping centers in Kashan, Iran. The risk assessment data and FRAME checklist were collected by observation and interviews. Data analysis was conducted using Excel and Geographic Information System (GIS) software. The results of 46 checklists showed that the mean score of fire risk R for property was equal to 3.12, for people 3.81 and for activities 1.86. Also, the lowest risk for the property, people and activities belongs to Golestan Center with a score of 1.40, Valiasr with a score of 1.25 and Ataee with a score of 1.15, and the highest risk for the property, people and activities belongs to Mir Seyfi Center with a score of 5.80, Shafagh with a score of 9.96 and Sabz was 2.62, respectively. The present study showed the lack of proper ventilation system, lack of emergency exits, and lack of automatic fire alarm and extinguishing system were the factors affecting fire risk. Therefore, in order to prevent disasters and uncontrollable critical conditions, it is necessary to review the equipment of these buildings and to design and implement fire detection and alarm equipment and different ways of fire control in these centers.
引用
收藏
页码:536 / 541
页数:6
相关论文
共 50 条
  • [1] Fire risk assessment using the building fire safety engineering method
    Building Research Assoc of New, Zealand, Porirua, New Zealand
    J Fire Prot Eng, 4 (157-168):
  • [2] Method of Risk Assessment on Metro Fire
    Mou, Ruifang
    PROCEEDINGS OF THE FIRST SYMPOSIUM ON DISASTER RISK ANALYSIS AND MANAGEMENT IN CHINESE LITTORAL REGIONS, 2011, 18 : 90 - 95
  • [3] Fire risk assessment using satellite data
    Hernandez-Leal, PA
    Arbelo, M
    Gonzalez-Calvo, A
    NATURAL HAZARDS AND OCEANOGRAPHIC PROCESSES FROM SATELLITE DATA, 2006, 37 (04): : 741 - 746
  • [4] A dynamic fire risk assessment method for compact historic villages based on the improved FRAME
    Liao, Danyan
    Zhuo, Xiaolan
    Tao, Jin
    INTERNATIONAL JOURNAL OF DISASTER RISK REDUCTION, 2024, 114
  • [5] Uncertainties in Fire Risk Assessment
    Teng Jinping
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL. VIII, PTS A AND B, 2010, 8 : 158 - 162
  • [6] Rapid fire risk assessment
    Gillett, JE
    HAZARDS XVI: ANALYSING THE PAST, PLANNING THE FUTURE, 2001, (148): : 337 - 349
  • [7] Fire risk assessment of cleanrooms
    Yun, Yeo-Song
    Song, Yun-Suk
    Lee, Young-soon
    Kim, Sung-Min
    Hyun, Seong-Ho
    Yoon, Myong-O
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 6, PTS A AND B, 2006, 6 : 889 - 895
  • [8] Fire and explosion risk assessment in a process unit using Dow's Fire and Explosion Index
    Nezamodini, Z. S.
    Rezvani, Z.
    Kian, K.
    JOURNAL OF HEALTH AND SAFETY AT WORK, 2015, 4 (04) : 29 - +
  • [9] Development of fire risk assessment method caused by earthquake
    Mitomo, N
    Matuskura, H
    Matsuoka, T
    Suzuki, K
    PSAM 5: PROBABILISTIC SAFETY ASSESSMENT AND MANAGEMENT, VOLS 1-4, 2000, (34): : 2105 - 2109
  • [10] The Development of Fire Risk Assessment Method for Heritage Building
    Ibrahim, M. N.
    Abdul-Hamid, K.
    Ibrahim, M. S.
    Mohd-Din, A.
    Yunus, R. M.
    Yahya, M. R.
    2ND INTERNATIONAL BUILDING CONTROL CONFERENCE, 2011, 20