Test-Retest Variability and Discriminatory Power of Measurements From Microperimetry and Dark Adaptation Assessment in People With Intermediate Age-Related Macular Degeneration - A MACUSTAR Study Report

被引:7
|
作者
Higgins, Bethany E. [1 ]
Montesano, Giovanni [1 ,2 ]
Dunbar, Hannah M. P. [3 ]
Binns, Alison M. [1 ]
Taylor, Deanna J. [1 ]
Behning, Charlotte [4 ]
Abdirahman, Amina [3 ]
Schmid, Matthias C. [4 ]
Terheyden, Jan H. [5 ]
Zakaria, Nadia [6 ]
Poor, Stephen [7 ]
Finger, Robert P. [5 ]
Leal, Sergio [8 ]
Holz, Frank G. [5 ]
Rubin, Gary S. [3 ]
Luhmann, Ulrich F. O. [9 ]
Crabb, David P. [10 ]
机构
[1] City Univ London, London, England
[2] Moorfields Eye Hosp NHS Fdn Trust, London, England
[3] UCL Inst Ophthalmol, London, England
[4] Univ Bonn, Inst Med Biometry Informat & Epidemiol, Med Fac, Bonn, Germany
[5] Univ Hosp Bonn, Dept Ophthalmol, Bonn, Germany
[6] Novartis Inst Biomed Res, Dept Translat Med, Cambridge, MA USA
[7] Novartis Inst Biomed Res, Dept Ophthalmol Res, Cambridge, MA USA
[8] Bayer AG, Berlin, Germany
[9] Roche Innovat Ctr Basel, Roche Pharmaceut Res & Early Dev, Translat Med Ophthalmol, Basel, Switzerland
[10] City Univ London, Optometry & Vis Sci, Northampton Sq, London EC1V 0HB, England
来源
关键词
test-retest; repeatability; macular integrity assessment (S-MAIA); AdaptDx; age-related macular degeneration (AMD); INTEGRITY ASSESSMENT; RELIABILITY; SENSITIVITY; PROGRESSION; PERIMETRY;
D O I
10.1167/tvst.12.7.19
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to assess test-retest variability and discriminatory power of measures from macular integrity assessment (S-MAIA) and AdaptDx.Methods: This is a cross-sectional study of 167 people with intermediate age-related macular degeneration (iAMD), no AMD (controls; n = 54), early AMD (n = 28), and late AMD (n = 41), recruited across 18 European ophthalmology centers. Repeat measures of mesopic and scotopic S-MAIA average (mean) threshold (MMAT decibels [dB] and SMAT [dB]) and rod intercept time (RIT [mins]) at 2 visits 14 (+/- 7) days apart were recorded. Repeat measures were assessed by Bland-Altman analysis, intra-class correlation coefficients (ICCs) and variability ratios. Secondary analysis assessed the area under the receiver operating characteristic curves (AUC) to determine the ability to distinguish people as having no AMD, early AMD, or iAMD.Results: Data were available for 128, 131, and 103 iAMD participants for the mesopic and scotopic S-MAIA and AdaptDx, respectively. MMAT and SMAT demonstrate similar test retest variability in iAMD (95% confidence interval [CI] ICC of 0.79-0.89 and 0.78-0.89, respectively). ICCs were worse in RIT (95% CI ICC = 0.55-0.77). All tests had equivalent AUCs (approximately 70%) distinguishing between subjects with iAMD and controls, whereas early AMD was indistinguishable from iAMD on all measures (AUC = <55%). A learning effect was not seen in these assessments under the operating procedures used. Conclusions: MMAT, SMAT, and RIT have adequate test-retest variability and are all moderately good at separating people with iAMD from controls.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Intrasession Test-Retest Variability of Microperimetry in Age-Related Macular Degeneration
    Wu, Zhichao
    Ayton, Lauren N.
    Guymer, Robyn H.
    Luu, Chi D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (12) : 7378 - 7385
  • [2] Retest variability of quantitative fundus autofluorescence and its determinants in age-related macular degeneration: A MACUSTAR study report
    von der Emde, Leon Alexander
    Mallwitz, Merten
    Schmitz-Valckenberg, Steffen
    Sassmannshausen, Marlene
    Sloan, Kenneth R.
    Vaisband, Marc
    Terheyden, Jan Henrik
    Finger, Robert Patrick
    Holz, Frank G.
    Ach, Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [3] Assessment of macular function by microperimetry in intermediate age-related macular degeneration
    Dinc, U. A.
    Yenerel, M.
    Gorgun, E.
    Oncel, M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (04) : 595 - 600
  • [4] Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report
    Leon von der Emde
    Merten Mallwitz
    Marc Vaisband
    Jan Hasenauer
    Marlene Saßmannshausen
    Jan Henrik Terheyden
    Kenneth R. Sloan
    Steffen Schmitz-Valckenberg
    Robert P. Finger
    Frank G. Holz
    Thomas Ach
    Scientific Reports, 13
  • [5] Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report
    von der Emde, Leon
    Mallwitz, Merten
    Vaisband, Marc
    Hasenauer, Jan
    Sassmannshausen, Marlene
    Terheyden, Jan Henrik
    Sloan, Kenneth R.
    Schmitz-Valckenberg, Steffen
    Finger, Robert P.
    Holz, Frank G.
    Ach, Thomas
    Agostini, H.
    Altay, L.
    Atia, R.
    Bandello, F.
    Basile, P. G.
    Batuca, J.
    Behning, C.
    Belmouhand, M.
    Berger, M.
    Binns, A.
    Boon, C. J. F.
    Boettger, M.
    Bouchet, C.
    Brazier, J. E.
    Butt, T.
    Carapezzi, C.
    Carlton, J.
    Carneiro, A.
    Charil, A.
    Coimbra, R.
    Cozzi, M.
    Crabb, D. P.
    Cunha-Vaz, J.
    Dahlke, C.
    de Sisternes, L.
    Dunbar, H.
    Finger, R. P.
    Fletcher, E.
    Floyd, H.
    Francisco, C.
    Gutfleisch, M.
    Hinz, S.
    Hogg, R.
    Holz, F. G.
    Hoyng, C. B.
    Kilani, A.
    Kratzschmar, J.
    Kuehlewein, L.
    Larsen, M.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [6] Determining optimal test parameters for assessing dark adaptation in people with intermediate age-related macular degeneration
    Binns, Alison M.
    Edwards, Laura
    Taylor, Deanna
    Crabb, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [7] Determining Optimal Test Parameters for Assessing Dark Adaptation in People With Intermediate Age-Related Macular Degeneration
    Binns, Alison M.
    Taylor, Deanna J.
    Edwards, Laura A.
    Crabb, David P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (04) : AMD114 - AMD121
  • [8] Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report
    Davide Garzone
    Jan Henrik Terheyden
    Olivier Morelle
    Maximilian W. M. Wintergerst
    Marlene Saßmannshausen
    Steffen Schmitz-Valckenberg
    Maximilian Pfau
    Sarah Thiele
    Stephen Poor
    Sergio Leal
    Frank G. Holz
    Robert P. Finger
    Scientific Reports, 12
  • [9] Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report
    Garzone, Davide
    Terheyden, Jan Henrik
    Morelle, Olivier
    Wintergerst, Maximilian W. M.
    Samannshausen, Marlene
    Schmitz-Valckenberg, Steffen
    Pfau, Maximilian
    Thiele, Sarah
    Poor, Stephen
    Leal, Sergio
    Holz, Frank G.
    Finger, Robert P.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [10] Intersession Repeatability of Structural Biomarkers in Early and Intermediate Age-Related Macular Degeneration: A MACUSTAR Study Report
    Sassmannshausen, Marlene
    Thiele, Sarah
    Behning, Charlotte
    Pfau, Maximilian
    Schmid, Matthias
    Leal, Sergio
    Luhmann, Ulrich F. O.
    Finger, Robert P.
    Holz, Frank G.
    Schmitz-Valckenberg, Steffen
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (03):