Apically extruded debris, canal transportation, and shaping ability of nickel-titanium instruments on contracted endodontic cavities in molar teeth

被引:2
|
作者
Zhang, Qinqin [1 ]
Gu, Jingyi [1 ]
Shen, Jiadi [1 ]
Ma, Ming [1 ]
Lv, Ying [1 ]
Wei, Xin [1 ,2 ]
机构
[1] Nanjing Med Univ, Affiliated Stomatol Hosp, Dept Endodont, Nanjing, Peoples R China
[2] Nanjing Med Univ, Affiliated Stomatol Hosp, Dept Endodont, 1 Shanghai Rd, Nanjing 210029, Peoples R China
关键词
apically extruded debris; canal transportation; contracted endodontic cavities; Ni-Ti instrument; shaping ability; traditional endodontic cavities; XP-ENDO SHAPER; COMPUTED TOMOGRAPHIC EVALUATION; DENTINAL MICROCRACK FORMATION; TREATED TEETH; CENTERING ABILITY; FRACTURE STRENGTH; ACCESS; IMPACT; RESISTANCE; THERAPY;
D O I
10.2334/josnusd.23-0050
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Apically extruded debris, canal transportation and shaping ability were compared between contracted endodontic cavities (CECs) and traditional endodontic cavities (TECs) after instrumentation with XP-endo Shaper (XPS), ProTaper Gold (PTG), ProTaper for hand-use (HPT) and Hero Shaper.Methods: The CECs or TECs groups were sub-divided into 24 groups according to root canal morphology and nickel-titanium (Ni-Ti) instruments. The weight of apically extruded debris was calculated using the Myers and Montgomery model. Pre-and postoperative images of teeth were scanned using micro-CT and the three-dimensional models were constructed and compared.Results: Under CECs or TECs, XPS and PTG produced less apical debris and formed less canal transportation than HPT and Hero Shaper (P < 0.05). XPS group under CECs extruded less apical debris than that under TCEs for round canals with curvature of 20 degrees-35 degrees (P < 0.05). The centering ratios of four tested instruments were higher under TECs than those under CECs (P < 0.05). The HPT and Hero Shaper had more transportation under CECs than that under TCEs (P < 0.05). No statistical difference was found regarding shaping ability among all the groups.Conclusion: Under CECs, XPS preserves the original root canal anatomy, meanwhile it produces less apical debris than the other instruments.
引用
收藏
页码:203 / 208
页数:6
相关论文
共 50 条
  • [1] Shaping Ability and Debris Extrusion of New Rotary Nickel-Titanium Root Canal Instruments
    Buerklein, Sebastian
    Donnermeyer, David
    Hentschel, Tim Julian
    Schaefer, Edgar
    MATERIALS, 2021, 14 (05) : 1 - 8
  • [2] An in vitro comparison of apically extruded debris using three rotary nickel-titanium instruments
    Tasdemir, Tamer
    Er, Kursat
    Celik, Davut
    Aydemir, Hikmet
    JOURNAL OF DENTAL SCIENCES, 2010, 5 (03) : 121 - 125
  • [3] Impacts of different Nickel-Titanium rotary and reciprocating root canal preparation systems on the amount of apically extruded debris
    Abduljalil, Mohamad
    Andac, Gizem
    Basmaci, Fatma
    AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 : 308 - 314
  • [4] Comparison of the amount of apically extruded debris during retreatment using different nickel-titanium systems and hand instruments in teeth with wide apices.
    Kayahan, Mehmet Baybora
    Ayhan, Tuba
    Guven, Esra Pamukcu
    Tanalp, Jale
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (07): : 3136 - 3139
  • [5] Evaluation of Apically Extruded Debris from Curved Root Canal Filling Removal Using 5 Nickel-Titanium Systems
    Canakci, Burhan Can
    Ustun, Yakup
    Er, Ozgur
    Sen, Ozgur Genc
    JOURNAL OF ENDODONTICS, 2016, 42 (07) : 1101 - 1104
  • [6] Re: 'Impacts of different Nickel-Titanium rotary and reciprocating root canal preparation systems on the amount of apically extruded debris'
    Grover, Srishti
    Shetty, Karthik
    AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 : 539 - 539
  • [7] Assessment of apically extruded debris and irrigant produced by different nickel-titanium instrument systems
    Kucukyilmaz, Ebru
    Savas, Selcuk
    Saygili, Gokhan
    Uysal, Banu
    BRAZILIAN ORAL RESEARCH, 2015, 29 (01):
  • [8] A comparison of the shaping characteristics of two nickel-titanium endodontic hand instruments
    Dobó-Nagy, C
    Serbán, T
    Szabó, J
    Nagy, G
    Madléna, M
    INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (03) : 283 - 288
  • [9] Evaluation of apically extruded debris during the canal preparation using new heat-treated nickel-titanium files in curved canals
    Duzgun, Salih
    Topcuoglu, Huseyin Sinan
    Kahraman, Omur
    AUSTRALIAN ENDODONTIC JOURNAL, 2021, 47 (01) : 54 - 58
  • [10] Comparison of Canal Transportation and Changes in Canal Curvature of Two Nickel-Titanium Rotary Instruments
    El Batouty, Kariem M.
    Elmallah, Waleed E.
    JOURNAL OF ENDODONTICS, 2011, 37 (09) : 1290 - 1292