Improved quantitative LC-MS/MS analysis of vitamin D metabolites in serum after one-pot double derivatization

被引:2
|
作者
Schorr, Pascal [1 ]
Stokes, Caroline S. [2 ]
Volmer, Dietrich A. [1 ]
机构
[1] Humboldt Univ, Dept Chem, Brook Taylor Str 2, D-12489 Berlin, Germany
[2] Humboldt Univ, Thaer Inst, Lentzeallee 75, D-14195 Berlin, Germany
关键词
Vitamin D; PTAD; Derivatization; Metabolites Epimer separation; LC-MS/MS; TANDEM MASS-SPECTROMETRY; 3-EPI-25-HYDROXYVITAMIN D3; 25-HYDROXYVITAMIN D2; DEPRESSIVE SYMPTOMS; D SUPPLEMENTATION; QUANTIFICATION; D-3; OVERESTIMATION; 3-ALPHA; PLASMA;
D O I
10.1016/j.jpba.2023.115522
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we report a one-pot double derivatization scheme, which used acetylation after a Diels-Alder reaction using 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD) to improve separation efficiency and provide baseline separations of the five vitamin D metabolites 1,25-dihydroxyvitamin D-3 (1,25(OH)(2)D-3), 24,25-dihydroxyvitamin D-3 (24,25(OH)(2)D-3), 3 beta-25-hydroxyvitamin D-3 (3 beta-25(OH)D-3), 3 alpha-25-hydroxyvitamin D-3 (3 alpha-25(OH)D-3) and vitamin D-3 on a C-18 stationary phase. Vitamin D metabolites are often very challenging to measure quantitatively using mass spectrometry, due to their low serum concentration levels and low ionization efficiencies. Moreover, some of these species are isomers with virtually identical mass spectral dissociation behavior. To overcome the low ionization efficiency and unspecific fragmentation behavior, derivatization using Diels-Alder reactions with Cookson-type reagents such as PTAD are common. These derivatization reactions generally result in more complicated liquid chromatography separations, because both 6R- and 6S-isomers are formed during Diels-Alder reactions. It has been shown that separations have been particularly challenging for the 3 alpha-25(OH)D-3 and 3 beta-25(OH)D-3 epimers. Here, we optimized the PTAD derivatization and the esterification using acetic anhydride. By utilizing the esterification catalyst 4-dimethylaminopyridine, we avoided quenching and evaporation between the two derivatization steps, but were also able to perform the esterification at room temperature without heating. The optimized one-pot double derivatization LC-MS/MS assay was validated with respect to inter/intra-day precision, accuracy, recovery and linear dynamic range and applied to metabolic fingerprinting of vitamin D3 metabolites in serum samples. The metabolites 3 alpha-25(OH)D-3, 3 beta-25(OH)D-3 and 24,25(OH)(2)D-3, were readily quantified in all investigated samples. The method was, in principle, also fit for purpose for quantification of the native vitamin D-3 species; the relatively high blank concentration of the commercial vitamin D-depleted serum used for calibration, however, limited the limits of quantification for this metabolite. The method provided insufficient limits of quantification for serum levels of 1,25(OH)(2)D-3.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Comparing derivatization reagents for quantitative LC-MS/MS analysis of a variety of vitamin D metabolites
    Alexandridou, Anastasia
    Schorr, Pascal
    Volmer, Dietrich A. A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (19) : 4689 - 4701
  • [2] Determination of vitamin D metabolites in serum using LC-MS and LC-MS/MS
    Bedner, Mary
    Phinney, Karen W.
    Sander, Lane C.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237 : 301 - 301
  • [3] Improved sample preparation method for fast LC-MS/MS analysis of vitamin D metabolites in serum
    Rola, R.
    Kowalski, K.
    Bienkowski, T.
    Studzinska, S.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 190
  • [4] Comparing derivatization reagents for quantitative LC–MS/MS analysis of a variety of vitamin D metabolites
    Anastasia Alexandridou
    Pascal Schorr
    Dietrich A. Volmer
    Analytical and Bioanalytical Chemistry, 2023, 415 : 4689 - 4701
  • [5] Stability of sample extracts of vitamin D3 metabolites after chemical derivatization for LC-MS/MS analysis
    Alexandridou, Anastasia
    Volmer, Dietrich A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (02) : 327 - 333
  • [6] Enhancing the Detection of Vitamin D Metabolites by LC-MS/MS Using a Novel Derivatization Kit
    Muramatsu, S.
    Nakagawa, T.
    Yokota, H.
    Wakui, M.
    Matsushita, H.
    CLINICAL CHEMISTRY, 2024, 70
  • [7] Quantitative analysis of methylmalonic acid in human plasma by LC-MS/ MS after derivatization
    Shen, Danhong
    Chen, Wei
    Liu, Jindi
    Liu, Yanhua
    Shi, Hongjun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1248
  • [8] Derivatization methods for quantitative bioanalysis by LC-MS/MS
    Deng, Pan
    Zhan, Yan
    Chen, Xiaoyan
    Zhong, Dafang
    BIOANALYSIS, 2012, 4 (01) : 49 - 69
  • [9] A novel LC-MS/MS method combined with derivatization for simultaneous quantification of vitamin D metabolites in human serum with diabetes as well as hyperlipidemia
    Wang, Xiaodi
    Qin, Qian
    Li, Fasheng
    Fu, Ying
    Liu, Na
    RSC ADVANCES, 2023, 13 (48) : 34157 - 34166
  • [10] Stability of sample extracts of vitamin D3 metabolites after chemical derivatization for LC–MS/MS analysis
    Anastasia Alexandridou
    Dietrich A. Volmer
    Analytical and Bioanalytical Chemistry, 2023, 415 : 327 - 333