Improved source localization in passive acoustic mapping using delay-multiply-and-sum beamforming with virtually augmented aperture

被引:4
|
作者
Shen, Che-Chou [1 ]
Chen, You-An [1 ]
Ku, Hsin-Yu [1 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, 43,Sect 4,Keelung Rd, Taipei 106, Taiwan
关键词
Passive acoustic mapping (PAM); Delay-multiply and sum (DMAS); Virtually augmented aperture; DMAS coherent factor (DCF); High-intensity focused ultrasound (HIFU); INTENSITY FOCUSED ULTRASOUND; BLOOD-BRAIN-BARRIER; CAVITATION; BUBBLE; TIME; EMISSIONS; TISSUE; LIVER;
D O I
10.1016/j.ultras.2023.107125
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
High-intensity focused ultrasound (HIFU) is a promising non-invasive treatment method whose applications include tissue ablation, hemostasis, thrombolysis and blood-brain barrier opening etc. Its therapeutic effects come from the thermal necrosis and the mechanical destruction associated with acoustic cavitation. Passive acoustic mapping (PAM) is capable of simultaneous monitoring of HIFU-induced cavitation events using only receive beamforming. Nonetheless, conventional time exposure acoustics (TEA) algorithm has poor spatial resolution and suffers from the X-shaped artifacts. These factors lead to difficulties in precise localization of cavitation source. In this study, we proposed a novel adaptive PAM method which combines Delay-Multiply-and-Sum (DMAS) beamforming with virtual augmented aperture (VA) to overcome the problem. In DMAS-VA beamforming, the magnitude of each channel waveform is scaled by p-th root while the phase is multiplied by L. The p and L correspond respectively to the degree of signal coherence in DMAS beamforming and the augmentation factor of aperture size. After channel sum, p-th power is applied to restore the dimensionality of source strength and then the PAM image is reconstructed by accumulating the signal power over the observation time. Based on simulation and experimental results, the proposed DMAS-VA has better image resolution and image contrast compared with the conventional TEA. Moreover, since the VA method may introduce grating lobes into PAM because of the virtually augmented pitch size, DMAS coherent factor (DCF) is further developed to alleviate these image artifacts. Results indicate that, with DCF weighting, the PAM image of DMAS-VA beamforming could be constructed without detectable image artifacts from grating lobes and false main lobes.
引用
收藏
页数:12
相关论文
共 10 条
  • [1] Passive Cavitation Mapping using Delay-Multiply-and-Sum (DMAS) Beamforming with Virtually Augmented (VA) Aperture
    Chen, You-An
    Shen, Che-Chou
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [2] Improved Real-time Delay-Multiply-and-Sum Beamforming with Coherence Factor
    Jeon, Seungwan
    Park, Eun-Yeong
    Choi, Wonseok
    Managuli, Ravi
    Lee, Ki Jong
    Kim, Chulhong
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2020, 2020, 11240
  • [3] Passive acoustic mapping with absolute time-of-flight information and delay-multiply-sum beamforming
    Lu, Shukuan
    Su, Ruibo
    Wan, Chunye
    Guo, Shifang
    Wan, Mingxi
    MEDICAL PHYSICS, 2023, 50 (04) : 2323 - 2335
  • [4] Low-complexity Delay-Multiply-and-Sum (DMAS) beamforming using baseband spatial coherence
    Shen, Che-Chou
    Hsieh, Pei-Ying
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [5] Delay multiply and sum beamforming method applied to enhance linear-array passive acoustic mapping of ultrasound cavitation
    Lu, Shukuan
    Li, Renyan
    Yu, Xianbo
    Wang, Diya
    Wan, Mingxi
    MEDICAL PHYSICS, 2019, 46 (10) : 4441 - 4454
  • [6] 2-Stage Delay-Multiply-And-Sum Beamforming for Breast Cancer Detection Using Microwave Imaging
    KaramFard, SeyedAbbas SeyedShah
    Asl, Babak Mohammadzadeh
    2017 25TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2017, : 101 - 106
  • [7] Image Enhancement and Noise Reduction Using Modified Delay-Multiply-and-Sum Beamformer: Application to Medical Photo acoustic Imaging
    Mozaffarzadeh, Moein
    Mahloojifar, Ali
    Orooji, Mahdi
    2017 25TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2017, : 65 - 69
  • [8] Enhanced contrast acoustic-resolution photoacoustic microscopy using double-stage delay-multiply-and-sum beamformer for vasculature imaging
    Mozaffarzadeh, Moein
    Varnosfaderani, Mehdi H. H.
    Sharma, Arunima
    Pramanik, Manojit
    de Jong, Nico
    Verweij, Martin D.
    JOURNAL OF BIOPHOTONICS, 2019, 12 (11)
  • [9] Improved Resolution and Crosstalk Rejection in Multi-Line Transmit Ultrasound Imaging Using Delay Multiply and Sum Beamforming
    Matrone, Giulia
    Ramalli, Alessandro
    Savoia, Alessandro Stuart
    Tortoli, Piero
    Magenes, Giovanni
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [10] An Improved Generalized Inverse Beamforming-Noise Source Localization Method Using Acoustic Vector Sensor Arrays
    Shi, Shengguo
    Gao, Yuan
    Yang, Desen
    Shi, Jie
    Tian, Deyan
    IEEE SENSORS JOURNAL, 2021, 21 (14) : 16222 - 16235