The impact of an ultrasound atlas for scoring salivary glands in primary Sjogren's syndrome: a pilot study

被引:0
|
作者
Schmidt, Nanna S. [1 ,2 ]
Fana, Viktoria [2 ]
Danielsen, Mads Ammitzboll [2 ]
Lindegaard, Hanne M. [1 ,3 ]
Voss, Anne [1 ,3 ]
Horn, Hans Christian [1 ]
Knudsen, John B. [1 ]
Byg, Keld-Erik [1 ,4 ]
Morillon, Melanie Birger [1 ,5 ]
Just, Soren Andreas [1 ,5 ]
Dohn, Uffe M. [2 ]
Terslev, Lene [2 ,6 ]
机构
[1] Odense Univ Hosp, Dept Rheumatol, Odense, Denmark
[2] Rigshosp, Copenhagen Ctr Arthrit Res, Ctr Rheumatol & Spine Dis, Glostrup, Denmark
[3] Univ Southern Denmark, Dept Clin Res, Odense, Denmark
[4] Odense Univ Hosp, Dept Neurol, Odense, Denmark
[5] Odense Univ Hosp, Svendborg Hosp, Dept Med, Sect Rheumatol, Svendborg, Denmark
[6] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
关键词
OMERACT; Reproducibility of results; Salivary glands; Sjogren's syndrome; Ultrasonography; CLASSIFICATION CRITERIA; AMERICAN-COLLEGE; ULTRASONOGRAPHY; RELIABILITY;
D O I
10.1007/s10067-023-06696-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective of this pilot study was to assess the impact of a salivary gland ultrasound (SGUS) atlas for scoring parenchymal changes in Sjogren's syndrome by assessing the reliability of the scoring system (0-3), without and with the use of the SGUS atlas. Ten participants with varying experience in SGUS contributed to the reliability exercise. Thirty SGUS images of the submandibular and parotid gland with abnormalities ranging from 0 to 3 were scored using the written definitions of the OMERACT SGUS scoring system and using the SGUS atlas based on the OMERACT scoring system. For intra-reader reliability, two rounds were performed without and with the atlas-in the 2nd round the 30 images were rearranged in random order by a physician not included in the scoring. Inter-reader reliability was also determined in both rounds. Without using the atlas, the SGUS OMERACT scoring system showed fair inter-reader reliability in round 1 (mean kappa 0.36; range 0.06-0.69) and moderate intra-reader reliability (mean kappa 0.55; range 0.28-0.81). With the atlas, inter-reader reliability improved in round 1 to moderate (mean kappa 0.52; range 0.31-0.77) and intra-reader reliability to good (mean kappa 0.69; range 0.46-0.86). Higher intra-reader reliability was noted in participants with previous SGUS experience. The SGUS atlas increased both intra- and inter-reader reliability for scoring gland pathology in participants with varying SGUS experience suggesting a possible future role in clinical practice and trials.
引用
收藏
页码:3275 / 3281
页数:7
相关论文
共 50 条
  • [1] THE IMPACT OF AN ULTRASOUND ATLAS FOR SCORING SALIVARY GLANDS IN PRIMARY SJOGREN'S SYNDROME: A RELIABILITY EXERCISE
    Schmidt, N. S.
    Fana, V.
    Lindegaard, H. M.
    Terslev, L.
    ANNALS OF THE RHEUMATIC DISEASES, 2020, 79 : 193 - 193
  • [2] The impact of an ultrasound atlas for scoring salivary glands in primary Sjögren’s syndrome: a pilot study
    Nanna S. Schmidt
    Viktoria Fana
    Mads Ammitzbøll Danielsen
    Hanne M. Lindegaard
    Anne Voss
    Hans Christian Horn
    John B. Knudsen
    Keld-Erik Byg
    Melanie Birger Morillon
    Søren Andreas Just
    Uffe M. Døhn
    Lene Terslev
    Clinical Rheumatology, 2023, 42 : 3275 - 3281
  • [3] Ultrasound elastography in assessment of salivary glands involvement in primary Sjogren's syndrome
    Cindil, Emetullah
    Oktar, Suna Ozhan
    Akkan, Koray
    Sendur, Halit Nahit
    Mercan, Ridvan
    Tufan, Abdurrahman
    Ozturk, Mehmet Akif
    CLINICAL IMAGING, 2018, 50 : 229 - 234
  • [4] COMPARISON OF ULTRASOUND AND SIALOGRAPHY OF MAJOR SALIVARY GLANDS IN PRIMARY SJOGREN'S SYNDROME
    Khvan, Y.
    Torgashina, A.
    Chaltsev, B.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2022, 40 (12) : 64 - 64
  • [5] APPLICATION OF THE OMERACT ULTRASOUND SCORING SYSTEM FOR SALIVARY GLANDS IN PATIENTS WITH SUSPECTED SJOGREN'S SYNDROME
    Bourguiba, R.
    Bellakhal, S.
    Charfi, M.
    Boudokhane, M.
    Bouhaouala, H.
    Douggui, M. H.
    Bouzaidi, K.
    ANNALS OF THE RHEUMATIC DISEASES, 2023, 82 : 2004 - 2004
  • [6] SCORING SYSTEMS IN ULTRASOUND OF SALIVARY GLANDS IN SJOGREN SYNDROME - A VIEW OVER TIME
    Iorgoveanu, V.
    Gheorghe, M.
    Mazilu, D.
    Bojinca, V.
    Groseanu, L.
    Balanes-Cu, A.
    Constantinescu, C.
    Vlad, V.
    Saulescu, I.
    Predeteanu, D.
    Ionescu, R.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2018, 36 (01) : S51 - S51
  • [7] VALIDITY OF THE NOVEL OMERACT ULTRASOUND SCORING SYSTEM FOR SALIVARY GLANDS TARGET LESIONS IN SJOGREN'S SYNDROME
    Inanc, N.
    Jousse-Joulin, S.
    Abacar, K. Y.
    Cimsit, C.
    Cimsit, C.
    D'Agostino, M.
    Naredo, E.
    Hocevar, A.
    Finzel, S.
    Terslev, L.
    Pineda, C.
    Keen, H.
    Iagnocco, A.
    Hanova, P.
    Schmidt, W. A.
    Mumcu, G.
    Bruyn, G. A.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2022, 40 (12) : 60 - 60
  • [8] Sonoelastography Evaluation of Salivary Glands in Primary Sjogren's Syndrome
    Zhang, X.
    Zhang, S. S.
    Li, J. G.
    Zhu, J. A.
    He, J.
    Li, Z. G.
    SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 2015, 81 (05) : 340 - 340
  • [9] Ultrasonography of Major Salivary Glands in Primary Sjogren's syndrome
    Jonsson, Malin V.
    Hammenfors, Daniel
    Brun, Johan G.
    Jonsson, Roland
    ARTHRITIS AND RHEUMATISM, 2012, 64 (10): : S925 - S925
  • [10] Ultrasonographic evaluation of major salivary glands in primary Sjogren's syndrome: comparison of two scoring systems
    Zhang, Xia
    Zhang, Shanshan
    He, Jing
    Hu, Fanlei
    Liu, Hongjiang
    Li, Jianguo
    Zhu, Jiaan
    Li, Zhanguo
    RHEUMATOLOGY, 2015, 54 (09) : 1680 - 1687