Inspection for Voids in the Grout below the Protective Duct of an External Post-Tensioning Bridge Tendon Using a THz A-Scanner

被引:0
|
作者
Yee, Dae-Su [1 ]
Yahng, Ji Sang [1 ]
Cho, Seung Hyun [1 ]
机构
[1] Korea Res Inst Stand & Sci KRISS, Safety Measurement Inst, Daejeon 34113, South Korea
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 22期
关键词
terahertz wave; nondestructive inspection; voids in grout; external tendon; post-tensioning bridge; TIME-DOMAIN SPECTROSCOPY; TERAHERTZ SPECTROSCOPY; FREQUENCY; THICKNESS; RESOLUTION; LASER;
D O I
10.3390/app132212119
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Grout voids in the tendons of a post-tensioning bridge reduce their strength. Grout voids are also severe flaws causing corrosion of the steel strands in the tendons. Detecting voids during construction and operation of the tendons is essential to prevent tendon failure, which is critical to bridge safety. This study presents a method for inspecting external tendons for voids in the grout below the protective duct pipe using terahertz electromagnetic waves. Due to low attenuation in the high-density polyethylene duct and the large reflectivity difference between the duct/grout and the duct/void interfaces, terahertz waves are suitable for detecting voids in the grout inside tendons. For this study, we developed a mobile frequency-domain terahertz A-scanner that can be used to measure terahertz A-scan data in real time. It is shown that the mobile terahertz A-scanner can be used to assess the area of the grout void in external bridge tendons.
引用
下载
收藏
页数:9
相关论文
共 8 条
  • [1] Nondestructive Inspection of Bridge Tendon Using a THz A-scanner
    Yee, Dae-Su
    Yahng, Ji Sang
    Cho, Seung Hyun
    2023 48TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, IRMMW-THZ, 2023,
  • [2] Monitoring of Grouting Compactness in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers
    Jiang, Tianyong
    Kong, Qingzhao
    Wang, Wenxi
    Huo, Linsheng
    Song, Gangbing
    SENSORS, 2016, 16 (08)
  • [3] Monitoring of Grouting Compactness in a Post-Tensioning Curve Tendon Duct Using Piezoceramic Transducers
    Jiang, Tianyong
    Jiang, Bin
    Zhang, Yaowen
    Tian, Zhongchu
    Song, Gangbing
    EARTH AND SPACE 2021: MATERIALS, STRUCTURES, DYNAMICS, AND CONTROL IN EXTREME ENVIRONMENTS, 2021, : 307 - 320
  • [4] Assessment of bridge Post-Tensioning systems using non-destructive (ND) inspection methods
    Quaglini, Virginio
    Pettorruso, Carlo
    Cattaneo, Sara
    Rossi, Dalila
    EUROPEAN ASSOCIATION ON QUALITY CONTROL OF BRIDGES AND STRUCTURES, EUROSTRUCT 2023, VOL 6, ISS 5, 2023, : 9 - 17
  • [5] Finite Element Analysis of Grouting Compactness Monitoring in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers
    Jiang, Tianyong
    Zheng, Junbo
    Huo, Linsheng
    Song, Gangbing
    SENSORS, 2017, 17 (10)
  • [6] Grouting monitoring of post-tensioning tendon duct using PZT enabled time-reversal method
    Tian, Zhen
    Huo, Linsheng
    Gao, Weihang
    Song, Gangbing
    Li, Hongnan
    MEASUREMENT, 2018, 122 : 513 - 521
  • [7] Second Remediation of Long-Term Deflection and Cracking of PT Box-Girder Bridge Using External Post-Tensioning
    Zhang, Xuhui
    Li, Shuang
    Zhang, Wei
    Ikechukwu, Ogwu
    Dai, Lizhao
    Wang, Lei
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2020, 34 (05)
  • [8] Flexural strengthening of precast reinforced concrete bridge girders using bonded carbon fibre reinforced polymer strips or external post-tensioning
    Sayed-Ahmed, EY
    Riad, AH
    Shrive, NG
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2004, 31 (03) : 499 - 512