Rapid and accurate screening of cystic echinococcosis in sheep based on serum Fourier-transform infrared spectroscopy combined with machine learning algorithms

被引:1
|
作者
Dawuti, Wubulitalifu [1 ,2 ]
Dou, Jingrui [1 ,2 ]
Zheng, Xiangxiang [3 ]
Lu, Xiaoyi [4 ]
Zhao, Hui [5 ]
Yang, Lingfei [6 ]
Lin, Renyong [2 ]
Lu, Guodong [1 ,2 ]
机构
[1] Xinjiang Med Univ, Sch Publ Hlth, Urumqi, Peoples R China
[2] First Affiliated Hosp Xinjiang Med Univ, Clin Med Res Inst, State Key Lab Pathogenesis Prevent & Treatment Ce, 137 Liyushan South Rd, Urumqi 830054, Peoples R China
[3] Beijing Univ Posts & Telecommun, Sch Elect Engn, Beijing, Peoples R China
[4] Xinjiang Univ, Coll Software, Urumqi, Peoples R China
[5] First Affiliated Hosp Xinjiang Med Univ, Dept Clin Lab, Urumqi, Peoples R China
[6] First Affiliated Hosp Xinjiang Med Univ, Dept Abdominal Ultrasound Diag, Urumqi, Peoples R China
关键词
cystic echinococcosis in sheep; Fourier transform infrared spectra; machine learning algorithms; screening; serum; FT-IR SPECTROSCOPY; OXIDATIVE STRESS; BREAST-CANCER; DIAGNOSIS; ULTRASOUND; BURDEN;
D O I
10.1002/jbio.202200320
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cystic echinococcosis (CE) in sheep is a serious zoonotic parasitic disease caused by Echinococcus granulosus sensu stricto (s.s.). Presently, the screening technology for CE in sheep is time-consuming and inaccurate, and novel screening technology is urgently needed. In this work, we combined machine-learning algorithms with Fourier transform infrared (FT-IR) spectroscopy of serum to establish a quick and accurate screening approach for CE in sheep. Serum samples from 77 E. granulosus s.s.-infected sheep to 121 healthy control sheep were measured by FT-IR spectrometer. To optimize the classification accuracy of the serum FI-TR method for the E. granulosus s.s.-infected sheep and healthy control sheep, principal component analysis (PCA), linear discriminant analysis, and support vector machine (SVM) algorithms were used to analyze the data. Among all the bands, 1500-1700 cm(-1) band has the best classification effect; its diagnostic sensitivity, specificity, and accuracy of PCA-SVM were 100%, 95.74%, and 96.66%, respectively. The study showed that serum FT-IR spectroscopy combined with machine learning algorithms has great potential for rapid and accurate screening methods for the CE in sheep.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Rapid and non-invasive detection of cystic echinococcosis in sheep based on serum fluorescence spectrum combined with machine learning algorithms
    Xu, Shengke
    Dawuti, Wubulitalifu
    Maimaitiaili, Maierhaba
    Dou, Jingrui
    Aizezi, Malike
    Aimulajiang, Kalibixiati
    Lu, Xiaoyi
    Lu, Guodong
    JOURNAL OF BIOPHOTONICS, 2024, 17 (04)
  • [2] Rapid screening for autoimmune diseases using Fourier transform infrared spectroscopy and deep learning algorithms
    Wu, Xue
    Shuai, Wei
    Chen, Chen
    Chen, Xiaomei
    Luo, Cainan
    Chen, Yi
    Shi, Yamei
    Li, Zhengfang
    Lv, Xiaoyi
    Chen, Cheng
    Meng, Xinyan
    Lei, Xin
    Wu, Lijun
    FRONTIERS IN IMMUNOLOGY, 2023, 14
  • [3] RAPID-SCAN INFRARED FOURIER-TRANSFORM SPECTROSCOPY
    GRIFFITHS, PR
    FOSKETT, CT
    CURBELO, R
    APPLIED SPECTROSCOPY REVIEWS, 1972, 6 (01) : 31 - +
  • [4] Fourier-transform infrared spectroscopy and machine learning algorithms can accurately classify and predict colitis and its severity
    Keung, C.
    Heraud, P.
    Moore, G.
    Sievert, W.
    Lim, R.
    Wood, B.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2020, 35 : 106 - 107
  • [5] Improved Classification Performance of Bacteria in Interference Using Raman and Fourier-Transform Infrared Spectroscopy Combined with Machine Learning
    Zhang, Pengjie
    Xu, Jiwei
    Du, Bin
    Yang, Qianyu
    Liu, Bing
    Xu, Jianjie
    Tong, Zhaoyang
    MOLECULES, 2024, 29 (13):
  • [6] Rapid discrimination of Brucellosis in sheep using serum Fourier transform infrared spectroscopy combined with PCA-LDA algorithm
    Dou, Jingrui
    Dawuti, Wubulitalifu
    Zheng, Xiangxiang
    Zhu, Yousen
    Lin, Renyong
    Lu, Guodong
    Zhang, Yujiang
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2023, 42
  • [7] Fourier-transform infrared spectroscopy for rapid screening and live-cell monitoring: application to nanotoxicology
    Sundaram, S. K.
    Sacksteder, Colette A.
    Weber, Thomas J.
    Riley, Brian J.
    Addleman, R. Shane
    Harrer, Bruce J.
    Peterman, John W.
    NANOMEDICINE, 2013, 8 (01) : 145 - 156
  • [8] Rapid detection of serological biomarkers in gallbladder carcinoma using fourier transform infrared spectroscopy combined with machine learning
    Dou, Jingrui
    Dawuti, Wubulitalifu
    Li, Jintian
    Zhao, Hui
    Zhou, Run
    Zhou, Jing
    Lin, Renyong
    Lu, Guodong
    TALANTA, 2023, 259
  • [9] Human serum mid-infrared spectroscopy combined with machine learning algorithms for rapid detection of gliomas
    Chen, Fangfang
    Meng, Chunzhi
    Qu, Hanwen
    Cheng, Chen
    Chen, Chen
    Yang, Bo
    Gao, Rui
    Lv, Xiaoyi
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2021, 35
  • [10] Fourier-transform infrared spectroscopy for the rapid identification of disease resistant trees
    Villari, C.
    Bonello, P.
    Sniezko, R.
    Rodriguez-Saona, L.
    PHYTOPATHOLOGY, 2016, 106 (12) : 170 - 170