Monitoring and Calibrating Building Materials Drying Kinetics with Capacitance Sensors

被引:0
|
作者
Karoglou, Maria [1 ]
Mouzakis, Charalampos [2 ]
Bakolas, Asterios [1 ]
Asimakopoulos, Simos [2 ]
Mustapha, Gamal [3 ]
机构
[1] Natl Tech Univ Athens, Sch Chem Engn, Athens 15780, Greece
[2] Natl Tech Univ Athens, Sch Civil Engn, Athens 15780, Greece
[3] Delta Controls Inc, Res & Dev, Surrey, BC V3S 1C7, Canada
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 02期
关键词
gravimetric method; stone; cement; lime; hydraulic lime; brick; MOISTURE-CONTENT;
D O I
10.3390/app14020578
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Building materials' moisture content defines the overall durability and serviceability of buildings and infrastructures. Conventionally, moisture content is estimated by weighing the materials before and after drying. In this work, the results of capacitance wired sensors for measuring moisture content were investigated. These sensors facilitate in situ measurement of capacitance values, with the aid of specialized installation equipment, and the results are accessible via a cloud-based software application. In practice, the main drawback associated with the application of these sensors is related to their calibration. Thus, it is important to investigate different algorithms which convert capacitance readings into moisture content values. To address this, various specimens covering a diverse set of building materials were prepared in the laboratory. This study focused on examining two bricks, two sedimentary stones with low and high porosity values. and four different kinds of mortars (with different binders, namely hydrated lime putty, cement, natural hydraulic lime, and hydrated lime powder and pozzolan). The results indicated that a linear model can be recommended for calibrating sensor capacitance to moisture content measurements. This model can be used for the prediction of building material moisture content with high accuracy, from saturated to the dry state, covering the full range of drying kinetics.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Drying kinetics of some building materials
    Karoglou, M
    Moropoulou, A
    Maroulis, ZB
    Krokida, MK
    DRYING TECHNOLOGY, 2005, 23 (1-2) : 305 - 315
  • [2] Drying kinetics of some building materials
    Moropoulou, A
    Karoglou, A
    Giakoumaki, A
    Krokida, MK
    Maroulis, ZB
    Saravacos, GD
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2005, 22 (02) : 203 - 208
  • [3] Experimental evaluation of drying kinetics of building materials
    Barreira, E.
    Delgado, J. M. P. Q.
    Ramos, N. M. M.
    de Freitas, V. P.
    CONTRIBUTIONS TO BUILDING PHYSICS, 2013, : 745 - 750
  • [4] Drying kinetics of building materials capillary moisture
    Karagiannis, Nikos
    Karoglou, Maria
    Bakolas, Asterios
    Krokida, Magdalini
    Moropoulou, Antonia
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 137 : 441 - 449
  • [5] Modeling and simulation of drying kinetics/curves: application to building materials
    Bennamoun L.
    Ndukwu M.C.
    Journal of Building Pathology and Rehabilitation, 2022, 7 (1)
  • [6] Modeling the Electrical Capacitance of Monitoring Sensors
    Novozhilov A.N.
    Yusupova A.O.
    Potapenko A.O.
    Russian Engineering Research, 2021, 41 (12) : 1135 - 1139
  • [7] Monitoring of high-moisture content particle drying in a fluidized bed by microwave and capacitance tomographic sensors
    Lin, Yonglei
    Yang, Wuqiang
    Wu, Zhipeng
    Wang, Haigang
    DRYING TECHNOLOGY, 2022, 40 (06) : 1153 - 1167
  • [8] Electrical conductivity sensors for water penetration monitoring in building masonry materials
    Guizzardi, M.
    Derome, D.
    Mannes, D.
    Vonbank, R.
    Carmeliet, J.
    MATERIALS AND STRUCTURES, 2016, 49 (07) : 2535 - 2547
  • [9] Electrical conductivity sensors for water penetration monitoring in building masonry materials
    M. Guizzardi
    D. Derome
    D. Mannes
    R. Vonbank
    J. Carmeliet
    Materials and Structures, 2016, 49 : 2535 - 2547
  • [10] A drying coefficient for building materials
    Scheffler, Gregor A.
    Plagge, Rudolf
    BAUPHYSIK, 2009, 31 (03) : 125 - 138