Seismic responses and failure mechanism of the superstructure-integrated underground structure considering the seismic aboveground-underground interaction

被引:3
|
作者
Qiu, Dapeng [1 ,2 ]
Wang, Peisen [1 ,2 ]
Ren, Wenjing [3 ]
Chen, Jianyun [4 ]
Zhao, Chunfeng [5 ]
机构
[1] Shandong Jianzhu Univ, Sch Civil Engn, Jinan, Peoples R China
[2] Shandong Jianzhu Univ, Key Lab Bldg Struct Retrofitting & Underground Sp, Minist Educ, Jinan 250101, Peoples R China
[3] Jinan Vocat Coll, Inst Equipment Infrastruct, Jinan, Peoples R China
[4] Dalian Univ Technol, Inst Earthquake Engn, Fac Infrastruct Engn, Dalian, Peoples R China
[5] Hefei Univ Technol, Coll Civil Engn, Hefei, Peoples R China
关键词
Superstructure-integrated underground; structure; Structural vibration; Seismic response; Seismic failure mechanism; Seismic aboveground-underground interaction; DYNAMIC-RESPONSES; PERFORMANCE; EXCAVATION;
D O I
10.1016/j.soildyn.2023.108259
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The superstructure-integrated underground structure (SIUS) is an innovative infrastructure in an urban city, in which the aboveground part and underground part are coupled together to be a large synthesis structure. During earthquakes, the SIUS is primarily influenced by the soil deformation and structural vibration, and the seismic aboveground-underground interaction (SAUI) would be considerable due to structural characteristics. This paper aims to investigate the seismic response and failure mechanism of the SIUS and reveal the influence mechanism of the SAUI with a quantitative method for the seismic aboveground-underground interaction coefficient (SAUIC). In this paper, a credible numerical model of the whole soil-SIUS system compiled with the viscous-spring artificial boundary is established. The modal analysis of the SIUS is carried out, and the distinctive structural characteristics are discussed. The seismic responses of the SIUS are thoroughly investigated, and the failure mechanism of vulnerable positions is further revealed. Based on the modal frequency response analysis and a novel correlation analysis, the SAUIC is quantitatively proposed to evaluate influence effects of the SAUI on seismic responses of the SIUS. The results show that the SAUI has great influence effects on seismic responses of the SIUS, even changes the seismic failure mode of the underground part to be flexural failure; the quantitative SAUIC demonstrates the SAUI increases with the increasing seismic intensity and increases from outside to inside of the SIUS, and the SAUI would be highly considerable on positions with irregularities in structural stiffness, especially on the aboveground-underground interface.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Seismic damage characteristics and evaluation of aboveground-underground coupled structures
    Li, Gang
    Zhang, Han
    Wang, Rui
    Dong, Zhi-Qian
    Yu, Ding-Hao
    ENGINEERING STRUCTURES, 2023, 283
  • [2] Seismic Response of Underground Subway and Aboveground Structures Considering the Tunnel-Soil-Aboveground Structure Interaction
    Fu, Yanbin
    Wang, Guobo
    Hu, Yu
    Mei, Chao
    Zhao, Xu
    JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (10) : 2655 - 2673
  • [3] Experimental study of seismic failure mechanism of underground structure
    Sun, Haifeng
    Jing, Liping
    Wang, Shuwei
    Meng, Xianchun
    Yanshilixue Yu Gongcheng Xuebao/Chinese Journal of Rock Mechanics and Engineering, 2013, 32 (SUPPL.2): : 3627 - 3635
  • [4] Influence of aboveground structure on connected underground structure seismic response within an integrated system
    Li, Wen -Ting
    Wang, Rui
    Zhang, Jian-Min
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 134
  • [5] Seismic responses of an underground tunnel considering rock-tunnel interaction
    Mei, Xiancheng
    Sheng, Qian
    Cui, Zhen
    Zhang, Maochu
    Chen, Liujie
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-GEOTECHNICAL ENGINEERING, 2022, 176 (05) : 434 - 452
  • [6] A simplified seismic design approach for cut and cover underground structure considering soil - Structure interaction
    Zhang, H.
    Qiu, Y.
    Huang, C.
    EARTHQUAKE GEOTECHNICAL ENGINEERING FOR PROTECTION AND DEVELOPMENT OF ENVIRONMENT AND CONSTRUCTIONS, 2019, 4 : 5849 - 5856
  • [7] Influence of vertical ground motion on the seismic response of underground structures and underground-aboveground structure systems in liquefiable ground
    Wang, Rui
    Zhu, Tong
    Yu, Jia-Ke
    Zhang, Jian-Min
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 122
  • [8] Shaking table test on the influence of underground space structure on the seismic response of adjacent superstructure
    Cheng Y.
    Pan D.-G.
    Chen Q.-J.
    Fu X.-Q.
    Li X.-J.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (01): : 91 - 99
  • [9] Seismic responses of underground cavern block in hydraulic engineering considering bond characteristics
    Li W.
    Tong D.
    Wang Z.
    Lu W.
    Zhu X.
    Zhong D.
    Lu, Wenyan (wylu@nhri.cn), 1600, Tianjin University (49): : 369 - 375
  • [10] Fuzzy seismic fragility analysis of underground structures considering multiple failure criteria
    Xu, Minze
    Cui, Chunyi
    Zhao, Jingtong
    Xu, Chengshun
    Zhang, Peng
    Su, Jian
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 145