Energy and exergy analysis of solar dryer with triple air passage direction collector powered by a wind generator

被引:13
|
作者
Ndukwu, Macmanus C. [1 ]
Okon, Bassey B. [2 ]
Abam, Fidelis, I [3 ]
Lamrani, Bilal [4 ]
Bekkioui, Naoual [5 ]
Wu, Hongwei [6 ]
Bennamoun, Lyes [7 ]
Egwu, Uchenna [8 ]
Ezewuisi, Chinemerem N. [1 ]
Ndukwe, Chibueze B. [1 ]
Nwachukwu, Chris [1 ]
Ehiem, James C. [1 ]
机构
[1] Michael Okpara Univ Agr, Dept Agr & Bioresources Engn, PMB 7267, Umuahia, Abia State, Nigeria
[2] Ibom State Univ Ikot Akpadem, Dept Mech Engn Akwa, Ikot Akpadem, Nigeria
[3] Michael Okpara Univ Agr, Dept Mech Engn, PMB 7267, Umuahia, Abia State, Nigeria
[4] Mohammed V Univ Rabat, Fac Sci, MANAPSE Lab, Rabat, Morocco
[5] Mohammed V Univ Rabat, Fac Sci, Lab Matiere Condensee & Sci Interdisciplinaires L, POB 1014, Rabat 1014, Morocco
[6] Univ Hertfordshire Hatfield, Sch Phys Engn & Comp Sci, Hatfield, Herts, England
[7] Univ New Brunswick, Dept Mech Engn, Federincon, NB, Canada
[8] Newcastle Univ, Sch Engn, Dept Civil Engn & Geomat, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
Collector design; Energy and exergy-based sustainability; Solar drying; Cocoyam; Wind generator; HEATER; PERFORMANCES; SYSTEM;
D O I
10.1007/s40095-022-00502-8
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The objective of this study is to thermodynamically investigate the performance of solar dryers by delaying the airflow in the collector. For this reason, a triple air path on a single pass collector with the fan powered by a wind generator was developed and evaluated in a very humid climate. The evaluation parameters were drying efficiency, energy and exergy analysis, sustainability assessment, CO2 mitigation ability and effective moisture diffusivity of dried product. The results showed that the collector efficiency of triple air passage path collector designs improved the direct passage collector by 119%. The overall collector and drying efficiencies were 8.43% and 2.6% higher than the direct flow path collector. The specific energy consumption was 1.1033 kWh/kg while the specific moisture extraction rate was obtained as 0.273 kg/kW, respectively. The average exergy efficiency ranged between 38.09 and 63.81% while the waste exergy ratio, improvement potential and sustainability index for the three dryers ranged from 0.00 to 1.13, 7.54 x 10(-7) to 2.003 kW and 0.00 to 11.47, respectively. Using the solar dryers instead of the coal-powered dryer will mitigate more CO2 into the atmosphere in the range of 9741.334 to 21,481. 476 tons of CO2 per year while using grid-based electricity will limit the least amount of CO2 in the range of 12.981 to 14.153351.50 tons of CO2 per year.
引用
下载
收藏
页码:63 / 77
页数:15
相关论文
共 50 条
  • [1] Energy and exergy analysis of solar dryer with triple air passage direction collector powered by a wind generator
    Macmanus C. Ndukwu
    Bassey B. Okon
    Fidelis I. Abam
    Bilal Lamrani
    Naoual Bekkioui
    Hongwei Wu
    Lyes Bennamoun
    Uchenna Egwu
    Chinemerem N. Ezewuisi
    Chibueze B. Ndukwe
    Chris Nwachukwu
    James C. Ehiem
    International Journal of Energy and Environmental Engineering, 2023, 14 : 63 - 77
  • [2] An Energy and Exergy Analysis of Water and Air with Different Passage in a Solar Collector
    Assari, M. R.
    Tabrizi, H. Basirat
    Jafari, I.
    Najafpour, E.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2014, 36 (07) : 747 - 754
  • [3] Advanced exergoeconomic and exergy performance assessments of a wind and solar energy powered hybrid dryer
    Atalay, Halil
    Aslan, Volkan
    RENEWABLE ENERGY, 2023, 209 : 218 - 230
  • [4] Novel hybrid active greenhouse solar dryer with evacuated tube solar collector: energy and exergy analysis
    Singh, Pushpendra
    Gaur, Manoj Kumar
    INTERNATIONAL JOURNAL OF EXERGY, 2023, 40 (03) : 282 - 302
  • [5] Numerical investigation on solar air collector and its practical application in the indirect solar dryer for banana chips drying with energy and exergy analysis
    Lingayat, Abhay
    Chandramohan, V. P.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 26
  • [6] AN ENERGY AND EXERGY STUDY OF A SOLAR THERMAL AIR COLLECTOR
    Mohseni-Languri, Ehsan
    Taherian, Hessam
    Masoodi, Reza
    Reisel, John R.
    THERMAL SCIENCE, 2009, 13 (01): : 205 - 216
  • [7] Energy and exergy analysis of different solar air collector systems with forced convection
    Bahrehmand, D.
    Ameri, M.
    Gholampour, M.
    RENEWABLE ENERGY, 2015, 83 : 1119 - 1130
  • [8] Energy and exergy analysis of a double-pass thermoelectric solar air collector
    Khasee, Naem
    Lertsatitthanakorn, Charoenporn
    Bubphachot, Bopit
    INTERNATIONAL JOURNAL OF EXERGY, 2013, 12 (01) : 1 - 10
  • [9] Energy and exergy analysis of different solar air collector systems with natural convection
    Bahrehmand, D.
    Ameri, M.
    RENEWABLE ENERGY, 2015, 74 : 357 - 368
  • [10] Evaluation of performance, energy, and exergy analysis of a solar parabolic dish collector connected to a dryer with nanofluid and PCM
    Jahromi, Mohammad Saleh Barghi
    Kalantar, Vali
    Samimi-Akhijahani, Hadi
    JOURNAL OF ENERGY STORAGE, 2024, 98