A Comparative Study of 64-Slice Coronary CT Angiography (CCTA) and Myocardial Perfusion Imaging (MPI) in the Identification of Coronary Artery Stenosis

被引:0
|
作者
Li, Bin [1 ]
Wu, Dandan [1 ]
机构
[1] First Peoples Hosp Linping Dist, Radiol Dept, Hangzhou 311199, Zhejiang, Peoples R China
来源
HEART SURGERY FORUM | 2023年 / 26卷 / 06期
关键词
coronary CT angiography; myocardial perfusion imaging; coronary artery stenosis; diagnostic accuracy; image quality; radiation exposure; procedure time; ACCURACY; SOCIETY; RISK;
D O I
10.59958/hsf.6685
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to compare the diagnostic accuracy of 64-Slice Coronary Computer Tomography Angiography (CCTA) and Myocardial Perfusion Imaging (MPI) in the identification of significant coronary artery stenosis (>50% luminal narrowing). Methods: A total of 120 patients suspected of having coronary artery disease were divided into two groups, with 60 patients in each group. Group 1 underwent CCTA and group 2 underwent MPI. Diagnostic accuracy parameters, image quality, radiation exposure, and procedure time were compared. Results: CCTA demonstrated higher sensitivity (90% vs. 80%, p = 0.049) and similar specificity (75% vs. 70%, p = 0.453) compared to MPI. Image quality was slightly superior in the CCTA group. Radiation exposure was significantly lower in the CCTA group compared to the MPI group (3.5 +/- 1.2 mSv vs. 9.4 +/- 1.7 mSv, p < 0.001). The procedure time for CCTA was also significantly less than that for MPI (10.3 +/- 2.1 minutes vs. 45.2 +/- 5.3 minutes, p < 0.001). Conclusion: CCTA showed superior sensitivity, image quality, and efficiency compared to MPI while exposing patients to a lower radiation dose. Further multicenter studies with larger patient populations are needed to validate these findings.
引用
收藏
页码:E722 / E727
页数:6
相关论文
共 50 条
  • [1] Comparison of 64-slice CT coronary angiography with CT cardiac function analysis and quantitative catheter angiography to myocardial perfusion imaging for predicting functionally relevant coronary artery stenosis
    Thilo, Christian
    Chiaramida, Sal
    Zwerner, Peter
    Nguyen, Shaun A.
    Costello, Philip
    Schoepf, U. Joseph
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 139A - 139A
  • [2] Combined quantitative analysis of 64-slice coronary CT angiography and myocardial perfusion SPECT
    Slomka, Piotr J.
    Suzuki, Yasuyuki
    Cheng, Victor
    Elad, Yaron
    Gutstein, Ariel
    Karlsberg, Ronald
    Germano, Guido
    Berman, Daniel
    Ramesh, Amit
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A173 - A173
  • [3] Accuracy of 64-slice coronary CT angiography (CCTA) for the diagnosis of functionally significant coronary artery disease (CAD) on SPECT stress/rest myocardial perfusion scintigraphy (MPS)
    Jessop, Aaron
    Walker, Ronald
    Delbeke, Dominique
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [4] 64-slice CT angiography for the detection of coronary artery stenoses
    Carol Lovegrove
    Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (1): : 7 - 7
  • [5] Comparison of 64-slice computed tomography coronary angiography, radionuclide myocardial perfusion imaging and stress echocardiogram in the detection of significant coronary artery stenosis.
    Spektor, Gary
    Waller, Alfonso H.
    Daraban, Nicoleta
    Duvall, William L.
    Michael, E. Farkouh
    Henziova, Milena J.
    Stern, Eric H.
    Goldman, Martin E.
    Croft, Lori B.
    Darrow, Bruce J.
    Fuster, Valentin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 142A - 143A
  • [6] 64-slice CT angiography for the detection of functionally significant coronary stenoses: comparison with stress myocardial perfusion imaging
    Chen, M-L
    Mo, Y-H
    Wang, Y-C
    Lo, H-S
    Wang, P-C
    Chao, I-M
    Su, H-Y
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1012): : 368 - 376
  • [7] Automatic alignment of myocardial perfusion PET with 64-slice coronary CT angiography on hybrid PET/CT
    Nakazato, Ryo
    Slomka, Piotr
    Alexanderson, Erick
    Meave, Aloha
    Jimenez-Santos, Moises
    Romero, Edgar
    Jacome, Rodrigo
    Pena, Marco
    Dey, Damini
    Berman, Daniel
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [8] Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT
    Ryo Nakazato
    Damini Dey
    Erick Alexánderson
    Aloha Meave
    Moisés Jiménez
    Edgar Romero
    Rodrigo Jácome
    Marco Peña
    Daniel S. Berman
    Piotr J. Slomka
    Journal of Nuclear Cardiology, 2012, 19 : 482 - 491
  • [9] Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT
    Nakazato, Ryo
    Dey, Damini
    Alexanderson, Erick
    Meave, Aloha
    Jimenez, Moises
    Romero, Edgar
    Jacome, Rodrigo
    Pena, Marco
    Berman, Daniel S.
    Slomka, Piotr J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (03) : 482 - 491
  • [10] Application of 64-slice Spiral CT in coronary artery imaging
    Wang, Jiaoyang
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (10) : 2 - 8